CVE-2021-37161
A buffer overflow issue was discovered in the HMI3 Control Panel contained within the Swisslog Healthcare Nexus Panel, operated by released versions of software before Nexus Software 7.2.5.7. A buffer overflow allows an attacker to overwrite an internal queue data structure and can lead to remote...
CVE-2021-37167
An insecure permissions issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released versions of software before Nexus Software 7.2.5.7. A user logged in using the default credentials can gain root access to the device, which provides permissions for all of t...
CVE-2021-37163
An insecure permissions issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus operated by released versions of software before Nexus Software 7.2.5.7. The device has two user accounts with passwords that are hardcoded...
CVE-2021-37164
A buffer overflow issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released versions of software before Nexus Software 7.2.5.7. In the tcpTxThread function, the received data is copied to a stack buffer. An off-by-3 condition can occur, resulting in a...
CVE-2021-37162
A buffer overflow issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released versions of software before Nexus Software 7.2.5.7. If an attacker sends a malformed UDP message, a buffer underflow occurs, leading to an out-of-bounds copy and possible remote co...
CVE-2021-37160
A firmware validation issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released versions of software before Nexus Software 7.2.5.7. There is no firmware validation e.g., cryptographic signature validation during a File Upload for a firmware update...
CVE-2021-37167
An insecure permissions issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released versions of software before Nexus Software 7.2.5.7. A user logged in using the default credentials can gain root access to the device, which provides permissions for all of t...
Buffer overflow
A buffer overflow issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released versions of software before Nexus Software 7.2.5.7. When a message is sent to the HMI TCP socket, it is forwarded to the hmiProcessMsg function through the pendingQ, and may lead t...
PT-2021-21547 · Swisslog · Swisslog Healthcare Nexus Panel
Name of the Vulnerable Software and Affected Versions: Swisslog Healthcare Nexus Panel versions prior to 7.2.5.7 Description: An insecure permissions issue was discovered in the HMI3 Control Panel of the Swisslog Healthcare Nexus Panel. This issue allows a user logged in using the default...
Swisslog Healthcare Nexus Panel 数字错误漏洞
Swisslog Healthcare Nexus Panel, a medical device from Swisslog Healthcare, is vulnerable to an integer underflow vulnerability in versions prior to Nexus Control Panel 7.2.5.7. An attacker could use this vulnerability to override the internal queue data structure, which could enable remote code...