89 matches found
Security update of chromium (low)
openSUSE Security Update: Security update of chromium Announcement ID: openSUSE-SU-2020:1181-1 Rating: low References: 1174582 Cross-References: CVE-2020-6532 CVE-2020-6537 CVE-2020-6538 CVE-2020-6539 CVE-2020-6540 CVE-2020-6541 Affected Products: openSUSE Backports SLE-15-SP2 An update that fixe...
Fedora 31 : chromium (2020-88bf0a76d1)
Update to Chromium 85.0.4183.83. Bugs fixed, security holes patched, and features added. Hold on to your butts. List of CVEs resolved with this update: CVE-2020-6532 CVE-2020-6537 CVE-2020-6538 CVE-2020-6539 CVE-2020-6540 CVE-2020-6541 CVE-2020-6542 CVE-2020-6543 CVE-2020-6544 CVE-2020-6545...
openSUSE Security Update : chromium (openSUSE-2020-1154)
Chromium was updated to 84.0.4147.105 boo1174582 : - CVE-2020-6537: Type Confusion in V8 - CVE-2020-6538: Inappropriate implementation in WebView - CVE-2020-6532: Use after free in SCTP - CVE-2020-6539: Use after free in CSS - CVE-2020-6540: Heap buffer overflow in Skia - CVE-2020-6541: Use after...
openSUSE: Security Advisory for Security (openSUSE-SU-2020:1154-1)
The remote host is missing an update for the Copyright C 2020 Greenbone Networks GmbH Some text descriptions might be excerpted from a referenced sources, and are Copyright C by the respective right holders. SPDX-License-Identifier: GPL-2.0-or-later This program is free software; you can...
OPENSUSE-SU-2020:1154-1 Security update of chromium
Chromium was updated to 84.0.4147.105 boo1174582: CVE-2020-6537: Type Confusion in V8 CVE-2020-6538: Inappropriate implementation in WebView CVE-2020-6532: Use after free in SCTP CVE-2020-6539: Use after free in CSS CVE-2020-6540: Heap buffer overflow in Skia CVE-2020-6541: Use after free in WebU...
GLSA-202007-59 : Chromium, Google Chrome: Multiple vulnerabilities
The remote host is affected by the vulnerability described in GLSA-202007-59 Chromium, Google Chrome: Multiple vulnerabilities Multiple vulnerabilities have been discovered in Chromium and Google Chrome. Please review the CVE identifiers referenced below for details. Impact : Please review the...
FreeBSD : chromium -- multiple vulnerabilities (9a447f78-d0f8-11ea-9837-e09467587c17)
Chrome Releases reports : This update contains 8 security fixes, including : - 1105318 High CVE-2020-6537: Type Confusion in V8. Reported by Alphalaab on 2020-07-14 - 1096677 High CVE-2020-6538: Inappropriate implementation in WebView. Reported by Yongke Wang@Rudykewang and Aryb1n@aryb1n of Tence...
KLA11917 Multiple vulnerabilities in Google Chrome
Multiple vulnerabilities were found in Google Chrome. Malicious users can exploit these vulnerabilities to cause denial of service, execute arbitrary code. Below is a complete list of vulnerabilities: 1. Use after free vulnerability in WebUSB can be exploited to cause denial of service. 2. Heap...
Google Chrome < 84.0.4147.105 Multiple Vulnerabilities
The version of Google Chrome installed on the remote macOS host is prior to 84.0.4147.105. It is, therefore, affected by multiple vulnerabilities as referenced in the 202007stable-channel-update-for-desktop27 advisory. - Use after free in WebUSB in Google Chrome prior to 84.0.4147.105 allowed a...
Huawei EulerOS: Security Advisory for zziplib (EulerOS-SA-2019-2478)
The remote host is missing an update for the Huawei EulerOS SPDX-FileCopyrightText: 2020 Greenbone AG Some text descriptions might be excerpted from a referenced sources, and are Copyright C by the respective right holders. SPDX-License-Identifier: GPL-2.0-only ifdescription...
CVE-2019-6540
The Conexus telemetry protocol utilized within Medtronic MyCareLink Monitor versions 24950 and 24952, CareLink Monitor version 2490C, CareLink 2090 Programmer, Amplia CRT-D, Claria CRT-D, Compia CRT-D, Concerto CRT-D, Concerto II CRT-D, Consulta CRT-D, Evera ICD, Maximo II CRT-D and ICD, Mirro IC...
CVE-2019-6540 Medtronic Conexus Radio Frequency Telemetry Protocol Cleartext Transmission of Sensitive Information
The Conexus telemetry protocol utilized within Medtronic MyCareLink Monitor versions 24950 and 24952, CareLink Monitor version 2490C, CareLink 2090 Programmer, Amplia CRT-D, Claria CRT-D, Compia CRT-D, Concerto CRT-D, Concerto II CRT-D, Consulta CRT-D, Evera ICD, Maximo II CRT-D and ICD, Mirro IC...
CVE-2019-6540
The CVE-2019-6540 issue is concrete: the Conexus telemetry protocol used by Medtronic MyCareLink/CareLink devices and related CRT-D/ICD hardware does not encrypt communications (Cleartext Transmission of Sensitive Information) and, per ICS-CERT, can be exploited by an attacker with adjacent, shor...
Medtronic Defibrillators Have Critical Flaws, Warns DHS
The Department of Homeland Security has issued an emergency alert warning of critical flaws allowing attackers to tamper with several Medtronic medical devices, including defibrillators. The two vulnerabilities – comprised of a medium and critical-severity flaw – exist in 20 products made by the...
Code injection
TrackR Bravo device allows unauthenticated pairing, which enables unauthenticated connected applications to write to various device attributes. Updated apps, version 5.1.6 for iOS and 2.2.5 for Android, have been released by the vendor to address the vulnerabilities in CVE-2016-6538, CVE-2016-653...
Code injection
The TrackR Bravo mobile app stores the account password used to authenticate to the cloud API in cleartext in the cache.db file. Updated apps, version 5.1.6 for iOS and 2.2.5 for Android, have been released by the vendor to address the vulnerabilities in CVE-2016-6538, CVE-2016-6539, CVE-2016-654...
CVE-2016-6538
The TrackR Bravo mobile app stores the account password used to authenticate to the cloud API in cleartext in the cache.db file. Updated apps, version 5.1.6 for iOS and 2.2.5 for Android, have been released by the vendor to address the vulnerabilities in CVE-2016-6538, CVE-2016-6539, CVE-2016-654...
Code injection
The Trackr device ID is constructed of a manufacturer identifier of four zeroes followed by the BLE MAC address in reverse. The MAC address can be obtained by being in close proximity to the Bluetooth device, effectively exposing the device ID. The ID can be used to track devices. Updated apps,...
CVE-2016-6540
Unauthenticated access to the cloud-based service maintained by TrackR Bravo is allowed for querying or sending GPS data for any Trackr device by using the tracker ID number which can be discovered as described in CVE-2016-6539. Updated apps, version 5.1.6 for iOS and 2.2.5 for Android, have been...
CVE-2016-6540 TrackR Bravo is missing authentication for the cloud service and allows querying or sending of GPS data from unauthenticated users
Unauthenticated access to the cloud-based service maintained by TrackR Bravo is allowed for querying or sending GPS data for any Trackr device by using the tracker ID number which can be discovered as described in CVE-2016-6539. Updated apps, version 5.1.6 for iOS and 2.2.5 for Android, have been...