419 matches found
多款WAGO产品 访问控制错误漏洞
WAGO Series PFC100 and others are products of WAGO, Germany.WAGO Series PFC100 is a programmable logic controller.WAGO Series PFC200 is a programmable logic controller.WAGO Edge Controller is an edge controller. An access control error vulnerability exists in multiple WAGO products. An attacker...
WAGO公司多款产品访问控制错误漏洞
WAGO Compact Controller CC100 and WAGO Edge Controller are both products of WAGO GmbH & Co. KG.WAGO Compact Controller CC100 is a compact controller.WAGO Edge Controller is an edge controller. An access control error vulnerability exists in some WAGO GmbH & Co. KG products. An attacker could use...
PT-2023-1472 · Wago · Wago Cc100 +3
Name of the Vulnerable Software and Affected Versions: WAGO PFC100/PFC200 versions affected versions not specified WAGO CC100 versions affected versions not specified WAGO Edge Controller versions affected versions not specified WAGO Touch Panel 600 versions affected versions not specified...
PT-2023-2008 · Wago · Wago Cc100 +3
Name of the Vulnerable Software and Affected Versions: WAGO PFC100/PFC200 versions affected versions not specified WAGO CC100 versions affected versions not specified WAGO Edge Controller versions affected versions not specified WAGO Touch Panel 600 versions affected versions not specified...
CVE-2022-32537 Medtronic MiniMed 600 Series Pump System Communication Issue
A vulnerability exists which could allow an unauthorized user to learn aspects of the communication protocol used to pair system components while the pump is being paired with other system components. Exploitation requires nearby wireless signal proximity with the patient and the device; advanced...
CVE-2022-32537 Medtronic MiniMed 600 Series Pump System Communication Issue
A vulnerability exists which could allow an unauthorized user to learn aspects of the communication protocol used to pair system components while the pump is being paired with other system components. Exploitation requires nearby wireless signal proximity with the patient and the device; advanced...
CVE-2022-3281
WAGO Series PFC100/PFC200, Series Touch Panel 600, Compact Controller CC100 and Edge Controller in multiple versions are prone to a loss of MAC-Address-Filtering after reboot. This may allow an remote attacker to circumvent the reach the network that should be protected by the MAC address filter...
Code injection
WAGO Series PFC100/PFC200, Series Touch Panel 600, Compact Controller CC100 and Edge Controller in multiple versions are prone to a loss of MAC-Address-Filtering after reboot. This may allow an remote attacker to circumvent the reach the network that should be protected by the MAC address filter...
CVE-2022-3281
CVE-2022-3281 affects WAGO Series PFC100/PFC200, Series Touch Panel 600, Compact Controller CC100 and Edge Controller. The issue is a loss of MAC-address filtering after reboot, which can allow remote attackers to bypass the network access control intended by MAC filtering. Documents consistently...
PT-2022-6077 · Wago · Compact Controller Cc100 +3
Name of the Vulnerable Software and Affected Versions: WAGO PFC100/PFC200 versions affected versions not specified WAGO Touch Panel 600 versions affected versions not specified WAGO Compact Controller CC100 versions affected versions not specified WAGO Edge Controller versions affected versions n...
Medtronic's MiniMed 600 series insulin pumps potentially at risk of compromise, says FDA
The US FDA Food and Drug Administration has warned users of Medtronic's MiniMed 600 Series Insulin Pump System--specifically, models for MiniMed 630G and MiniMed 670G--that their medical devices have a cybersecurity issue with its communication protocol. If compromised, attackers could gain...
Medtronic NGP 600 Series 安全漏洞
The Medtronic NGP 600 Series is a line of insulin pumps and accessories from Medtronic, Inc. A security vulnerability exists in Medtronic NGP 600 Series version 2.4, which originates from the exploitation of wireless signals that require proximity to the patient and the device. The following...
CISA Releases Eight industrial Control Systems Advisories
CISA has released eight 8 Industrial Control Systems ICS advisories on September 20, 2022. These advisories provide timely information about current security issues, vulnerabilities, and exploits surrounding ICS. CISA encourages users and administrators to review the newly released ICS advisories...
PT-2022-4147 · Siemens · Scalance W-700 +9
Name of the Vulnerable Software and Affected Versions: SCALANCE M-800 / S615 versions prior to V2.3.1 SCALANCE SC-600 family versions prior to V2.3.1 SCALANCE W-1700 IEEE 802.11ac family versions prior to V2.3.1 SCALANCE W-700 IEEE 802.11ax family versions prior to V2.3.1 SCALANCE W-700 IEEE...
Siemens SCALANCE
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories CERT Services | Services |...
CVE-2022-22535
SAP ERP HCM Portugal - versions 600, 604, 608, does not perform necessary authorization checks for a report that reads the payroll data of employees in a certain area. Since the affected report only reads the payroll information, the attacker can neither modify any information nor cause...
CVE-2022-22535
SAP ERP HCM Portugal - versions 600, 604, 608, does not perform necessary authorization checks for a report that reads the payroll data of employees in a certain area. Since the affected report only reads the payroll information, the attacker can neither modify any information nor cause...
AlmaLinux 8 : kernel (ALSA-2021:0558)
The remote AlmaLinux 8 host has packages installed that are affected by multiple vulnerabilities as referenced in the ALSA-2021:0558 advisory. - A flaw was found in the Linux kernel. A use-after-free memory flaw was found in the perf subsystem allowing a local attacker with permission to monitor...
CVE-2021-37471
Cradlepoint IBR900-600 devices running versions 7.21.10 are vulnerable to a restricted shell escape sequence that provides an attacker the capability to simultaneously deny availability to the device's NetCloud Manager console, local console and SSH command-line...
CVE-2021-37471
Cradlepoint IBR900-600 devices running versions 7.21.10 are vulnerable to a restricted shell escape sequence that provides an attacker the capability to simultaneously deny availability to the device's NetCloud Manager console, local console and SSH command-line...