87 matches found
CVE-2022-32518
A CWE-522: Insufficiently Protected Credentials vulnerability exists that could result in unwanted access to a DCE instance when performed over a network by a malicious third-party. This CVE is unique from CVE-2022-32520. Affected Products: Data Center Expert Versions prior to V7.9.0...
CVE-2022-32518
A CWE-522: Insufficiently Protected Credentials vulnerability exists that could result in unwanted access to a DCE instance when performed over a network by a malicious third-party. This CVE is unique from CVE-2022-32520. Affected Products: Data Center Expert Versions prior to V7.9.0...
CVE-2022-32520
A CWE-522: Insufficiently Protected Credentials vulnerability exists that could result in unwanted access to a DCE instance when performed over a network by a malicious third-party. This CVE is unique from CVE-2022-32518. Affected Products: Data Center Expert Versions prior to V7.9.0...
CVE-2022-32520
The CVE-2022-32520 entry affects Schneider Electric Data Center Expert before version 7.9.0. It describes a CWE-522 vulnerability (insufficiently protected credentials) that could allow a malicious remote actor to gain unauthorized access to a DCE instance over a network. The connected sources co...
CVE-2022-32520
A CWE-522: Insufficiently Protected Credentials vulnerability exists that could result in unwanted access to a DCE instance when performed over a network by a malicious third-party. This CVE is unique from CVE-2022-32518. Affected Products: Data Center Expert Versions prior to V7.9.0...
CVE-2022-32518
CVE-2022-32518 affects Schneider Electric Data Center Expert prior to version 7.9.0. It is a CWE-522 Insufficiently Protected Credentials flaw that could allow unauthorized access to a DCE instance over a network by a malicious third party. The vulnerability impact is described as high/critical i...
Siemens SINUMERIK ONE and SINUMERIK MC
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please seeSiemens' ProductCERT Security Advisories CERT Services | Services |...
Red Lion DA50N
1. EXECUTIVE SUMMARY CVSS v3 9.6 ATTENTION: Exploitable remotely/low attack complexity Vendor: Red Lion Equipment: DA50N Vulnerabilities: Insufficient Verification of Data Authenticity, Weak Password Requirements, Use of Unmaintained Third-Party Components, Insufficiently Protected Credentials 2...
CVE-2021-22798
A CWE-522: Insufficiently Protected Credentials vulnerability exists that could cause Sensitive data such as login credentials being exposed when a Network is sniffed. Affected Product: Conext� ComBox All Versions...
Design/Logic Flaw
A CWE-522: Insufficiently Protected Credentials vulnerability exists that could cause Sensitive data such as login credentials being exposed when a Network is sniffed. Affected Product: Conext? ComBox All Versions...
CVE-2021-22798
The CVE-2021-22798 issue affects Schneider Electric Conext ComBox (All Versions) and is described as CWE-522: Insufficiently Protected Credentials. The vulnerability could allow exposure of sensitive data (e.g., login credentials) when a network is sniffed. Root cause: credentials are not adequat...
CVE-2021-22798
A CWE-522: Insufficiently Protected Credentials vulnerability exists that could cause Sensitive data such as login credentials being exposed when a Network is sniffed. Affected Product: Conext� ComBox All Versions...
FortiSDNConnector - Credential leak
An insufficiently protected credentials vulnerability CWE-522 in FortiSDNConnector may allow an authenticated user to obtain third party device credentials via visiting the configuration page in the WebUI...
GitHub Security Lab: [Python] CWE-522: Insecure LDAP Authentication
This bug was reported directly to GitHub Security Lab...
ICSMA-21-196-01_Ypsomed mylife
1. EXECUTIVE SUMMARY CVSS v3 6.3 ATTENTION: Exploitable remotely/low attack complexity Vendor: Ypsomed Equipment: mylife Cloud, mylife Mobile Application Vulnerabilities: Insufficiently Protected Credentials, Not Using an Unpredictable IV with CBC Mode, Use of Hard-coded Credentials 2. RISK...
Schneider Electric Modicon Controllers and Software (Update A)
1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION: Exploitable remotely/low attack complexity Vendor : Schneider Electric Equipment : EcoStruxure Control Expert, EcoStruxure Process Expert, SCADAPack RemoteConnect x70, SCADAPack x70 RTUs, and Modicon M580 and M340 control products Vulnerabilities :...
CVE-2020-28219
A CWE-522: Insufficiently Protected Credentials vulnerability exists in EcoStruxure Geo SCADA Expert 2019 Original release and Monthly Updates to September 2020, from 81.7268.1 to 81.7578.1 and EcoStruxure Geo SCADA Expert 2020 Original release and Monthly Updates to September 2020, from 83.7551....
CVE-2020-28219
A CWE-522: Insufficiently Protected Credentials vulnerability exists in EcoStruxure Geo SCADA Expert 2019 Original release and Monthly Updates to September 2020, from 81.7268.1 to 81.7578.1 and EcoStruxure Geo SCADA Expert 2020 Original release and Monthly Updates to September 2020, from 83.7551....
CVE-2020-28219
CVE-2020-28219 affects EcoStruxure Geo SCADA Expert 2019 and 2020, with a CWE-522 vulnerability that could expose credentials to server-side users when web users are logged in to Virtual ViewX. Affected versions include EcoStruxure Geo SCADA Expert 2019 (Original release and Monthly Updates throu...
02-522-5050.com Cross Site Scripting vulnerability OBB-1419180
Following coordinated and responsible vulnerability disclosure guidelines of the ISO 29147 standard, Open Bug Bounty has:       a. verified the vulnerability and confirmed its existence;       b. notified the website operator about its existence...