906 matches found
DEBIAN-CVE-2014-6393
The Express web framework before 3.11 and 4.x before 4.5 for Node.js does not provide a charset field in HTTP Content-Type headers in 400 level responses, which might allow remote attackers to conduct cross-site scripting XSS attacks via characters in a non-standard encoding...
CVE-2014-6393
The Express web framework before 3.11 and 4.x before 4.5 for Node.js does not provide a charset field in HTTP Content-Type headers in 400 level responses, which might allow remote attackers to conduct cross-site scripting XSS attacks via characters in a non-standard encoding...
Design/Logic Flaw
Specially crafted PROFINET DCP packets sent on a local Ethernet segment Layer 2 to an affected product could cause a denial of service condition of that product. Human interaction is required to recover the system. PROFIBUS interfaces are not affected. This vulnerability affects only SIMATIC HMI...
CVE-2017-2681
CVE-2017-2681 affects Siemens PROFINET DCP; specially crafted DCP packets on a local Layer-2 Ethernet can cause denial of service in affected devices. The issue primarily impacts SIMATIC HMI Multi Panels, HMI Mobile Panels, and S7-300/S7-400 families, plus a wide range of PROFINET-enabled product...
Siemens SIMATIC HMI Denial of Service Vulnerability
SIMATIC HMI is an industrial device from Siemens, Germany.SIMATIC HMI panels are used for operator control and monitoring of machines and equipment. A denial of service vulnerability in the Siemens SIMATIC HMI Multi-Panel and HMI Mobile Panels, as well as in the S7-300/S7-400 devices, allows an...
Siemens devices using the PROFINET Discovery and Configuration Protocol (Update G)
CVSS v3 6.5 ATTENTION: Exploitable from an adjacent network/low skill level to exploit. Vendor: Siemens Equipment: Devices using the PROFINET Discovery and Configuration Protocol DCP Vulnerability: Denial of Service UPDATE INFORMATION This updated advisory is a follow-up to the updated advisory...
Siemens devices using the PROFINET Discovery and Configuration Protocol (Update D)
CVSS v3 6.5 ATTENTION: Exploitable from an adjacent network/low skill level to exploit. Vendor: Siemens Equipment: Devices using the PROFINET Discovery and Configuration Protocol DCP Vulnerability: Denial of Service UPDATE INFORMATION This updated advisory is a follow-up to the updated advisory...
Siemens devices using the PROFINET Discovery and Configuration Protocol (Update F)
CVSS v3 6.5 ATTENTION: Exploitable from an adjacent network/low skill level to exploit. Vendor: Siemens Equipment: Devices using the PROFINET Discovery and Configuration Protocol DCP Vulnerability: Denial of Service UPDATE INFORMATION This updated advisory is a follow-up to the updated advisory...
Moderate: Red Hat Security Advisory: tomcat security update
An update for tomcat is now available for Red Hat Enterprise Linux 7. Red Hat Product Security has rated this update as having a security impact of Moderate. A Common Vulnerability Scoring System CVSS base score, which gives a detailed severity rating, is available for each vulnerability from the...
BackBox OS Denial Of Service Exploit
Exploit for linux platform in category dos / poc Exploit Title: BackBox OS Denial Of ServiceCPU Consumption CVE: CVE-2017-7397 CWE: CWE-400 Exploit Author: Hosein Askari FarazPajohan Vendor HomePage: https://backbox.org/ Version : 4.6 Exploit Tested on: Ubuntu 16.04 Date: 01-04-2017 Category:...
PloitKit - The Hacker's ToolBox
PloitKit is a Python based GUI tool designed as one-stop for all other softwares. I was facing these kinds of problem, when I need to switch to different system, or I lost my pen-drive. I have to go to google, and search every tool and download every tool and so on. So I decided to create a tool,...
baike.com XSS vulnerability
Vulnerable URL: http://www.baike.com/docClaimApply.do?action=showClaimDocApply=adya4cz%22onfocus%3d%22alert%28/OPENBUGBOUNTY/%29%22autofocus%3d%22rbo8n Details: Description| Value ---|--- Patched:| No Latest check for patch:| 30.07.2017 Vulnerability type:| XSS Vulnerability status:| Publicly...
Schneider Electric Conext ComBox
CVSS v3 7.5 ATTENTION: Remotely exploitable/low skill level to exploit. Vendor: Schneider Electric Equipment: Conext ComBox Vulnerability: Resource Exhaustion AFFECTED PRODUCTS Schneider Electric reports that the vulnerability affects the following Conext ComBox solar battery monitor: Conext...
[SECURITY] [DSA 3788-2] tomcat8 regression update
------------------------------------------------------------------------- Debian Security Advisory DSA-3788-2 [email protected] https://www.debian.org/security/ Salvatore Bonaccorso February 22, 2017 https://www.debian.org/security/faq -...
[SECURITY] [DSA 3787-2] tomcat7 regression update
------------------------------------------------------------------------- Debian Security Advisory DSA-3787-2 [email protected] https://www.debian.org/security/ Salvatore Bonaccorso February 22, 2017 https://www.debian.org/security/faq -...
Design/Logic Flaw
A vulnerability has been identified in SIMATIC S7-300 CPU family All versions, SIMATIC S7-300 CPU family incl. related ET200 CPUs and SIPLUS variants All versions, SIMATIC S7-400 PN/DP V6 and below CPU family incl. SIPLUS variants All versions, SIMATIC S7-400 PN/DP V7 CPU family incl. SIPLUS...
Design/Logic Flaw
A vulnerability has been identified in SIMATIC S7-300 CPU family All versions, SIMATIC S7-300 CPU family incl. related ET200 CPUs and SIPLUS variants All versions, SIMATIC S7-400 PN/DP V6 and below CPU family incl. SIPLUS variants All versions, SIMATIC S7-400 PN/DP V7 CPU family incl. SIPLUS...
CVE-2016-9158
A vulnerability has been identified in SIMATIC S7-300 CPU family All versions, SIMATIC S7-300 CPU family incl. related ET200 CPUs and SIPLUS variants All versions, SIMATIC S7-400 PN/DP V6 and below CPU family incl. SIPLUS variants All versions, SIMATIC S7-400 PN/DP V7 CPU family incl. SIPLUS...
CVE-2016-9159
A vulnerability has been identified in SIMATIC S7-300 CPU family All versions, SIMATIC S7-300 CPU family incl. related ET200 CPUs and SIPLUS variants All versions, SIMATIC S7-400 PN/DP V6 and below CPU family incl. SIPLUS variants All versions, SIMATIC S7-400 PN/DP V7 CPU family incl. SIPLUS...
CVE-2016-9159
The vulnerability CVE-2016-9159 affects Siemens SIMATIC S7-300/400 PLC families (including related ET200/SIPLUS variants) where an attacker with network access to port 102/TCP (ISO-TSAP) or via Profibus can obtain credentials if protection-level 2 is configured. The ICS-CISA advisory SSA-731239 d...