Lucene search
+L

906 matches found

Tenable Nessus
Tenable Nessus
added 2019/05/08 12:0 a.m.15 views

Rockwell Automation PowerFlex 700 VC 400/480V Compact IO/DPI

Binary data 754688.prm...

7.3AI score
SaveExploits0References1
Kitploit
Kitploit
added 2019/04/07 9:31 p.m.729 views

ISF - Industrial Control System Exploitation Framework

ISFIndustrial Exploitation Framework is a exploitation framework based on Python, it's similar to metasploit framework. ISF is based on open source project routersploit. Read this in other languages:English, 简体中文, ICS Protocol Clients Name | Path | Description ---|---|--- modbustcpclient |...

8.1CVSS8.7AI score0.0591EPSS
SaveExploits1References16
ICS
ICS
added 2019/03/28 12:0 a.m.67 views

Rockwell Automation PowerFlex 525 AC Drives

1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: Rockwell Automation Equipment: PowerFlex 525 AC Drives Vulnerability: Resource Exhaustion 2. RISK EVALUATION Successful exploitation of this vulnerability could result in resource exhaustion,...

10CVSS9.9AI score0.05645EPSS
SaveExploits0References4
OSV
OSV
added 2019/03/21 4:0 p.m.7 views

CVE-2018-20218

An issue was discovered on Teracue ENC-400 devices with firmware 2.56 and below. The login form passes user input directly to a shell command without any kind of escaping or validation in /usr/share/www/check.lp file. An attacker is able to perform command injection using the "password" parameter...

9.8CVSS5.8AI score0.10735EPSS
SaveExploits5References2
NVD
NVD
added 2019/03/21 4:0 p.m.21 views

CVE-2018-20220

An issue was discovered on Teracue ENC-400 devices with firmware 2.56 and below. While the web interface requires authentication before it can be interacted with, a large portion of the HTTP endpoints are missing authentication. An attacker is able to view these pages before being authenticated,...

7.5CVSS7.6AI score0.15362EPSS
SaveExploits4References3
NVD
NVD
added 2019/03/21 4:0 p.m.29 views

CVE-2018-20219

An issue was discovered on Teracue ENC-400 devices with firmware 2.56 and below. After successful authentication, the device sends an authentication cookie to the end user such that they can access the devices web administration panel. This token is hard-coded to a string in the source code...

9.3CVSS8.3AI score0.14553EPSS
SaveExploits4References3
OSV
OSV
added 2019/03/21 4:0 p.m.5 views

CVE-2018-20219

An issue was discovered on Teracue ENC-400 devices with firmware 2.56 and below. After successful authentication, the device sends an authentication cookie to the end user such that they can access the devices web administration panel. This token is hard-coded to a string in the source code...

8.1CVSS5.8AI score0.14553EPSS
SaveExploits4References3
NVD
NVD
added 2019/03/21 4:0 p.m.25 views

CVE-2018-20218

An issue was discovered on Teracue ENC-400 devices with firmware 2.56 and below. The login form passes user input directly to a shell command without any kind of escaping or validation in /usr/share/www/check.lp file. An attacker is able to perform command injection using the "password" parameter...

10CVSS9.7AI score0.10735EPSS
SaveExploits5References2
OSV
OSV
added 2019/03/21 4:0 p.m.3 views

CVE-2018-20220

An issue was discovered on Teracue ENC-400 devices with firmware 2.56 and below. While the web interface requires authentication before it can be interacted with, a large portion of the HTTP endpoints are missing authentication. An attacker is able to view these pages before being authenticated,...

7.5CVSS5.7AI score0.15362EPSS
SaveExploits4References3
Prion
Prion
added 2019/03/21 4:0 p.m.13 views

Authentication flaw

An issue was discovered on Teracue ENC-400 devices with firmware 2.56 and below. While the web interface requires authentication before it can be interacted with, a large portion of the HTTP endpoints are missing authentication. An attacker is able to view these pages before being authenticated,...

5CVSS8AI score0.15362EPSS
SaveExploits4References3Affected Software3
Prion
Prion
added 2019/03/21 4:0 p.m.18 views

Authentication flaw

An issue was discovered on Teracue ENC-400 devices with firmware 2.56 and below. After successful authentication, the device sends an authentication cookie to the end user such that they can access the devices web administration panel. This token is hard-coded to a string in the source code...

9.3CVSS8.7AI score0.14553EPSS
SaveExploits4References3Affected Software3
Prion
Prion
added 2019/03/21 4:0 p.m.22 views

Command injection

An issue was discovered on Teracue ENC-400 devices with firmware 2.56 and below. The login form passes user input directly to a shell command without any kind of escaping or validation in /usr/share/www/check.lp file. An attacker is able to perform command injection using the "password" parameter...

10CVSS9.7AI score0.10735EPSS
SaveExploits5References2Affected Software3
Cvelist
Cvelist
added 2019/03/17 8:51 p.m.38 views

CVE-2018-20220

An issue was discovered on Teracue ENC-400 devices with firmware 2.56 and below. While the web interface requires authentication before it can be interacted with, a large portion of the HTTP endpoints are missing authentication. An attacker is able to view these pages before being authenticated,...

8.1AI score0.15362EPSS
SaveExploits4References3
CVE
CVE
added 2019/03/17 8:51 p.m.59 views

CVE-2018-20220

Teracue ENC-400 devices with firmware 2.56 and below expose a set of pre-authentication HTTP endpoints lacking authentication, enabling an attacker to view pages before login and potentially disclose sensitive information. Red‑team sources and vulnerability trackers reference command injection an...

7.5CVSS8.6AI score0.15362EPSS
SaveExploits4References3Affected Software1
Cvelist
Cvelist
added 2019/03/17 8:47 p.m.40 views

CVE-2018-20219

An issue was discovered on Teracue ENC-400 devices with firmware 2.56 and below. After successful authentication, the device sends an authentication cookie to the end user such that they can access the devices web administration panel. This token is hard-coded to a string in the source code...

8.7AI score0.14553EPSS
SaveExploits4References3
CVE
CVE
added 2019/03/17 8:47 p.m.76 views

CVE-2018-20219

CVE-2018-20219 (Teracue ENC-400) affects firmware 2.56 and earlier. Public documents confirm an authentication bypass caused by a hard-coded cookie/token stored in /usr/share/www/check.lp that permits access to the web admin panel after login, enabling persistent access without a password. Even p...

9.3CVSS9.1AI score0.14553EPSS
SaveExploits4References3Affected Software1
Cvelist
Cvelist
added 2019/03/17 8:41 p.m.41 views

CVE-2018-20218

An issue was discovered on Teracue ENC-400 devices with firmware 2.56 and below. The login form passes user input directly to a shell command without any kind of escaping or validation in /usr/share/www/check.lp file. An attacker is able to perform command injection using the "password" parameter...

9.8AI score0.10735EPSS
SaveExploits5References2
CVE
CVE
added 2019/03/17 8:41 p.m.80 views

CVE-2018-20218

Summary (CVE-2018-20218): Teracue ENC-400 devices running firmware 2.56 or below are affected by a command-injection vulnerability in the login form. The issue arises because the login input is passed directly to a shell command in /usr/share/www/check.lp without escaping or validation, enabling ...

10CVSS9.7AI score0.10735EPSS
SaveExploits5References2Affected Software1
BDU FSTEC
BDU FSTEC
added 2019/03/12 12:0 a.m.9 views

The vulnerability of microprogrammed software in Siemens Simatic S7-400 programmable logic controllers is related to errors in checking input data by Ethernet, PROFIBUS, and MPI interfaces. This allows a malicious actor to trigger a service failure.

The vulnerability of microprogrammed programmable logic controllers from Siemens Simatic S7-400 is related to errors in the validation of input data by Ethernet, PROFIBUS, and MPI interfaces. Exploiting this vulnerability can allow an attacker to cause maintenance failures by sending a specially...

8.5CVSS7.4AI score0.00821EPSS
SaveExploits0References3Affected Software4
BDU FSTEC
BDU FSTEC
added 2019/03/12 12:0 a.m.8 views

The vulnerability of microprogrammed software in Siemens Simatic S7-400 programmable logic controllers is related to errors in checking input data by Ethernet, PROFIBUS, and MPI interfaces. This allows a malicious actor to trigger a service failure.

The vulnerability of microprogrammed programmable logic controllers from Siemens Simatic S7-400 is related to errors in the validation of input data by Ethernet, PROFIBUS, and MPI interfaces. Exploiting this vulnerability can allow an attacker to cause malfunctions in the system by sending a...

7.8CVSS7.2AI score0.01545EPSS
SaveExploits0References3Affected Software4
Rows per page
Query Builder