945 matches found
Siemens S7-400 CPUs Improper Verification of Cryptographic Signature (CVE-2018-16557)
A vulnerability has been identified in SIMATIC S7-400 incl. F V6 and below All versions, SIMATIC S7-400 PN/DP V7 incl. F All versions, SIMATIC S7-400H V4.5 and below All versions, SIMATIC S7-400H V6 All versions V6.0.9, SIMATIC S7-410 All versions V8.2.1. Sending of specially crafted packets to...
Siemens SIMATIC Denial of Service (CVE-2012-3016)
Siemens SIMATIC S7-400 PN CPU devices with firmware 6 before 6.0.3 allow remote attackers to cause a denial of service defect-mode transition and service outage via crafted ICMP packets. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more...
Siemens Industrial Real-Time Devices Improper Input Validation (CVE-2019-10923)
A vulnerability has been identified in Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller, Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200, Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P, SCALANCE X-200IRT switch family incl. SIPLUS NET variants,...
Siemens SIMATIC CP 343-1/CP 443-1 Modules and SIMATIC S7-300/S7-400 CPUs (CVE-2016-8673)
A vulnerability has been identified in SIMATIC CP 343-1 Advanced incl. SIPLUS NET variant All versions V3.0.53, SIMATIC CP 443-1 Advanced incl. SIPLUS NET variant All versions V3.2.17, SIMATIC S7-300 PN/DP CPU family incl. SIPLUS variants All versions, SIMATIC S7-400 PN/DP CPU family incl. SIPLUS...
Siemens SIMATIC Improper Restriction of Operations within the Bounds of a Memory Buffer (CVE-2012-3017)
Siemens SIMATIC S7-400 PN CPU devices with firmware 5.x allow remote attackers to cause a denial of service defect-mode transition and service outage via 1 malformed HTTP traffic or 2 malformed IP packets. This plugin only works with Tenable.ot. Please visit...
CVE-2022-22724
A CWE-400: Uncontrolled Resource Consumption vulnerability exists that could cause a denial of service on ports 80 HTTP and 502 Modbus, when sending a large number of TCP RST or FIN packets to any open TCP port of the PLC. Affected Product: Modicon M340 CPUs: BMXP34 All Versions...
Denial of service
A CWE-400: Uncontrolled Resource Consumption vulnerability exists that could cause a denial of service on ports 80 HTTP and 502 Modbus, when sending a large number of TCP RST or FIN packets to any open TCP port of the PLC. Affected Product: Modicon M340 CPUs: BMXP34 All Versions...
CVE-2022-22724
CVE-2022-22724 affects Schneider Electric Modicon M340 BMXP34 controllers (all versions). The root cause is CWE-400 Uncontrolled Resource Consumption, enabling a denial of service by flooding TCP ports 80 (HTTP) and 502 (Modbus) with a large number of RST/FIN packets to any open TCP port. Documen...
CVE-2022-22724
A CWE-400: Uncontrolled Resource Consumption vulnerability exists that could cause a denial of service on ports 80 HTTP and 502 Modbus, when sending a large number of TCP RST or FIN packets to any open TCP port of the PLC. Affected Product: Modicon M340 CPUs: BMXP34 All Versions...
CVE-2021-22813
A CWE-79: Improper Neutralization of Input During Web Page Generation 'Cross-site Scripting' vulnerability exists that could cause arbritrary script execution when a privileged account clicks on a malicious URL specifically crafted for the NMC pointing to an edit policy file. Affected Products:...
Mageia: Security Advisory (MGASA-2021-0341)
The remote host is missing an update for the SPDX-FileCopyrightText: 2022 Greenbone AG Some text descriptions might be excerpted from a referenced sources, and are Copyright C by the respective right holders. SPDX-License-Identifier: GPL-2.0-only ifdescription...
Fernhill SCADA
1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low attack complexity Vendor: Fernhill Software, Ltd. Equipment: Fernhill SCADA Server Vulnerability: Uncontrolled Resource Consumption 2. RISK EVALUATION Successful exploitation of this vulnerability could cause a denial-of-service...
CVE-2021-20044
A post-authentication remote command injection vulnerability in SonicWall SMA100 allows a remote authenticated attacker to execute OS system commands in the appliance. This vulnerability affected SMA 200, 210, 400, 410 and 500v appliances...
CVE-2021-20045
A buffer overflow vulnerability in SMA100 sonicfiles RACCOPYTO RacNumber 36 method allows a remote unauthenticated attacker to potentially execute code as the 'nobody' user in the appliance. This vulnerability affected SMA 200, 210, 400, 410 and 500v appliances...
CVE-2021-20042
An unauthenticated remote attacker can use SMA 100 as an unintended proxy or intermediary undetectable proxy to bypass firewall rules. This vulnerability affected SMA 200, 210, 400, 410 and 500v appliances...
CVE-2021-20044
A post-authentication remote command injection vulnerability in SonicWall SMA100 allows a remote authenticated attacker to execute OS system commands in the appliance. This vulnerability affected SMA 200, 210, 400, 410 and 500v appliances...
Design/Logic Flaw
An unauthenticated remote attacker can use SMA 100 as an unintended proxy or intermediary undetectable proxy to bypass firewall rules. This vulnerability affected SMA 200, 210, 400, 410 and 500v appliances...
Buffer overflow
A buffer overflow vulnerability in SMA100 sonicfiles RACCOPYTO RacNumber 36 method allows a remote unauthenticated attacker to potentially execute code as the 'nobody' user in the appliance. This vulnerability affected SMA 200, 210, 400, 410 and 500v appliances...
Command injection
A post-authentication remote command injection vulnerability in SonicWall SMA100 allows a remote authenticated attacker to execute OS system commands in the appliance. This vulnerability affected SMA 200, 210, 400, 410 and 500v appliances...
Heap overflow
A Heap-based buffer overflow vulnerability in SonicWall SMA100 getBookmarks method allows a remote authenticated attacker to potentially execute code as the nobody user in the appliance. This vulnerability affected SMA 200, 210, 400, 410 and 500v appliances...