864 matches found
PT-2023-13979 · Sage · Sage 300
Name of the Vulnerable Software and Affected Versions: Sage 300 versions through 2022 Description: The optional Web Screens feature uses a hard-coded 40-byte blowfish key PASS KEY to encrypt and decrypt the database connection string for the PORTAL database found in the "dbconfig.xml". This issue...
CVE-2022-41398
CVE-2022-41398 affects Sage 300 (through 2022) where the optional Global Search feature configures Apache Solr with hard-coded admin credentials. This enables login to the Solr dashboard with admin privileges and potential exposure of sensitive data. The Red Hat/Red flags and other records corrob...
CVE-2022-41397
CVE-2022-41397 concerns Sage 300 (through version 2022) where the optional Web Screens and Global Search features use a hard-coded 40-byte Blowfish key, “LandlordPassKey,” to encrypt/decrypt secrets stored in configuration files and in database tables. This key is embedded in the feature’s encryp...
CVE-2022-41400
Sage 300 through 2022 uses a hard-coded 40-byte blowfish key to encrypt and decrypt user passwords and SQL connection strings stored in ISAM database files in the shared data directory. This issue could allow attackers to decrypt user passwords and SQL connection strings...
PT-2023-13977 · Sage · Sage 300
Name of the Vulnerable Software and Affected Versions: Sage 300 versions through 2022 Description: The issue concerns the use of a hard-coded 40-byte blowfish key, specifically LandlordPassKey, for encrypting and decrypting secrets stored in configuration files and database tables. This is relate...
Sage Group Sage 300 信任管理问题漏洞
Sage Group Sage 300 is a well-established closed-source Enterprise Resource Planning ERP solution from Sage Group, UK, designed to facilitate the management of organizations. A security vulnerability exists in Sage Group Sage 300 version 2022 and prior versions, which stems from the use of a...
CVE-2022-41399
The CVE-2022-41399 issue affects Sage 300 (through 2022) where the optional Web Screens feature uses a hard-coded 40-byte Blowfish key (PASS_KEY) to encrypt/decrypt the PORTAL database connection string in dbconfig.xml. This cryptographic weakness could allow an attacker to access the SQL databas...
Siemens Multiple RTOS Integer Overflow or Wraparound (CVE-2020-35198)
An issue was discovered in Wind River VxWorks 7. The memory allocator has a possible integer overflow in calculating a memory block's size to be allocated by calloc. As a result, the actual memory allocated is smaller than the buffer size specified by the arguments, leading to memory corruption...
Siemens Multiple RTOS Integer Overflow or Wraparound (CVE-2020-28895)
In Wind River VxWorks, memory allocator has a possible overflow in calculating the memory block's size to be allocated by calloc. As a result, the actual memory allocated is smaller than the buffer size specified by the arguments, leading to memory corruption. SCALANCE X-200, X-200IRT, and X-300...
[SECURITY] Fedora 38 Update: kernel-6.2.12-300.fc38
The kernel meta package...
Siemens SCALANCE Switch Families
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please seeSiemens' ProductCERT Security Advisories CERT Services | Services |...
ABB Central Licensing System Improper Restriction of XML External Entity Reference (CVE-2020-8479)
For the Central Licensing Server component used in ABB products ABB Ability System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus -S+ Engineering 1.1 to...
ABB Central Licensing System Uncontrolled Resource Consumption (CVE-2020-8475)
For the Central Licensing Server component used in ABB products ABB Ability System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus -S+ Engineering 1.1 to...
ABB Multiple System 800xA Products Incorrect Default Permissions (CVE-2020-8485)
Insufficient protection of the inter-process communication functions in ABB System 800xA for MOD 300 all published versions enables an attacker authenticated on the local system to inject data, allowing reads and writes to the controllers or cause windows processes to crash. This plugin only work...
Debian: Security Advisory (DLA-300-1)
The remote host is missing an update for the Debian SPDX-FileCopyrightText: 2023 Greenbone AG Some text descriptions might be excerpted from a referenced sources, and are Copyright C by the respective right holders. SPDX-License-Identifier: GPL-2.0-only ifdescription...
CVE-2023-22389
Snap One Wattbox WB-300-IP-3 versions WB10.9a17 and prior store passwords in a plaintext file when the device configuration is exported via Save/Restore–Backup Settings, which could be read by any user accessing the file...
CVE-2023-22315
Snap One Wattbox WB-300-IP-3 versions WB10.9a17 and prior use a proprietary local area network LAN protocol that does not verify updates to the device. An attacker could upload a malformed update file to the device and execute arbitrary code...
CVE-2023-24020
Snap One Wattbox WB-300-IP-3 versions WB10.9a17 and prior could bypass the brute force protection, allowing multiple attempts to force a login...
Design/Logic Flaw
Snap One Wattbox WB-300-IP-3 versions WB10.9a17 and prior could bypass the brute force protection, allowing multiple attempts to force a login...
Code injection