92882 matches found
CVE-2020-5953
A vulnerability exists in System Management Interrupt SWSMI handler of InsydeH2O UEFI Firmware code located in SWSMI handler that dereferences gRT EFIRUNTIMESERVICES pointer to call a GetVariable service, which is located outside of SMRAM. This can result in code execution in SMM escalating...
CVE-2020-5296
In OctoberCMS october/october composer package versions from 1.0.319 and before 1.0.466, an attacker can exploit this vulnerability to delete arbitrary local files of an October CMS server. The vulnerability is only exploitable by an authenticated backend user with the cms.manageassets permission...
CVE-2020-5575
Cross-site scripting vulnerability in Movable Type series Movable Type 7 r.4606 7.2.1 and earlier Movable Type 7, Movable Type Advanced 7 r.4606 7.2.1 and earlier Movable Type Advanced 7, Movable Type for AWS 7 r.4606 7.2.1 and earlier Movable Type for AWS 7, Movable Type 6.5.3 and earlier Movabl...
CVE-2020-5179
Comtech Stampede FX-1010 7.4.3 devices allow remote authenticated administrators to execute arbitrary OS commands by navigating to the Diagnostics Ping page and entering shell metacharacters in the Target IP address field. In some cases, authentication can be achieved with the comtech password fo...
CVE-2020-5531
Mitsubishi Electric MELSEC C Controller Module and MELIPC Series MI5000 MELSEC-Q Series C Controller ModuleQ24DHCCPU-V, Q24DHCCPU-VG User Ethernet port CH1, CH2: First 5 digits of serial number 21121 or before, MELSEC iQ-R Series C Controller Module / C Intelligent Function ModuleR12CCPU-V Ethern...
CVE-2020-5180
Viscosity 1.8.2 on Windows and macOS allows an unprivileged user to set a subset of OpenVPN parameters, which can be used to load a malicious library into the memory of the OpenVPN process, leading to limited local privilege escalation. When a VPN connection is initiated using a TLS/SSL client...
CVE-2020-5603
Uncontrolled resource consumption vulnerability in Mitsubishi Electoric FA Engineering Software CPU Module Logging Configuration Tool Ver. 1.94Y and earlier, CW Configurator Ver. 1.010L and earlier, EM Software Development Kit EM Configurator Ver. 1.010L and earlier, GT Designer3 GOT2000 Ver...
CVE-2020-5935
On BIG-IP LTM, AAM, AFM, Analytics, APM, ASM, DNS, FPS, GTM, Link Controller, PEM versions 15.1.0-15.1.0.5, 14.1.0-14.1.2.3, and 13.1.0-13.1.3.3, when handling MQTT traffic through a BIG-IP virtual server associated with an MQTT profile and an iRule performing manipulations on that traffic, TMM m...
CVE-2020-5225
Log injection in SimpleSAMLphp before version 1.18.4. The www/erroreport.php script, which receives error reports and sends them via email to the system administrator, did not properly sanitize the report identifier obtained from the request. This allows an attacker, under specific circumstances,...
CVE-2020-5658
Resource Management Errors vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are '02' or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are '01' or before,...
CVE-2020-5955
An issue was discovered in Int15MicrocodeSmm in Insyde InsydeH2O before 2021-10-14 on Intel client chipsets. A caller may be able to escalate privileges...
CVE-2020-5801
An attacker can craft and send an OpenNamespace message to port 4241 with valid session-id that triggers an unhandled exception in CFTLDManager::HandleRequest function in RnaDaSvr.dll, resulting in process termination. Observed in FactoryTalk Linx 6.11. All versions of FactoryTalk Linx are affect...
CVE-2020-5289
In Elide before 4.5.14, it is possible for an adversary to "guess and check" the value of a model field they do not have access to assuming they can read at least one other field in the model. The adversary can construct filter expressions for an inaccessible field to filter a collection. The...
CVE-2020-5676
GROWI v4.1.3 and earlier allow remote attackers to obtain information which is not allowed to access via unspecified vectors...
CVE-2020-5551
Toyota 2017 Model Year DCU Display Control Unit allows an unauthenticated attacker within Bluetooth range to cause a denial of service attack and/or execute an arbitrary command. The affected DCUs are installed in Lexus LC, LS, NX, RC, RC F, TOYOTA CAMRY, and TOYOTA SIENNA manufactured in the...
CVE-2020-5722
The HTTP interface of the Grandstream UCM6200 series is vulnerable to an unauthenticated remote SQL injection via crafted HTTP request. An attacker can use this vulnerability to execute shell commands as root on versions before 1.0.19.20 or inject HTML in password recovery emails in versions befo...
CVE-2020-5281
In Perun before version 3.9.1, VO or group manager can modify configuration of the LDAP extSource to retrieve all from Perun LDAP. Issue is fixed in version 3.9.1 by sanitisation of the input...
CVE-2020-5766
Improper Neutralization of Special Elements used in an SQL Command 'SQL Injection' in SRS Simple Hits Counter Plugin for WordPress 1.0.3 and 1.0.4 allows a remote, unauthenticated attacker to determine the value of database fields...
CVE-2020-5542
Buffer error vulnerability in TCP function included in the firmware of Mitsubishi Electric MELQIC IU1 series IU1-1M20-D firmware version 1.0.7 and earlier allows remote attackers to stop the network functions or execute malware via a specially crafted packet...
CVE-2020-5298
In OctoberCMS october/october composer package versions from 1.0.319 and before 1.0.466, a user with the ability to use the import functionality of the ImportExportController behavior can be socially engineered by an attacker to upload a maliciously crafted CSV file which could result in a...