92455 matches found
CVE-2020-12246
Beeline Smart Box 2.0.38 routers allow "Advanced settings Other Diagnostics" OS command injection via the Ping pingipaddr parameter, the Nslookup nslookupipaddr parameter, or the Traceroute tracerouteipaddr parameter...
CVE-2020-12345
Improper permissions in the installer for the IntelR Data Center Manager Console before version 3.6.2 may allow an authenticated user to potentially enable escalation of privilege via local access...
CVE-2020-12705
Multiple cross-site scripting XSS vulnerabilities exist in LeptonCMS before 4.6.0...
CVE-2020-12624
The League application before 2020-05-02 on Android sends a bearer token in an HTTP Authorization header to an arbitrary web site that hosts an external image because an OkHttp object is reused, which allows remote attackers to hijack sessions...
CVE-2020-12750
An issue was discovered on Samsung mobile devices with Q10.0 software. Attackers can bypass Factory Reset Protection FRP via SPEN. The Samsung ID is SVE-2020-17019 May 2020...
CVE-2020-12714
An issue was discovered in CipherMail Community Gateway Virtual Appliances and Professional/Enterprise Gateway Virtual Appliances versions 1.0.1 through 4.7.1-0 and CipherMail Webmail Messenger Virtual Appliances 1.1.1 through 3.1.1-0. A Diffie-Hellman parameter of insufficient size could allow...
CVE-2020-12462
The ninja-forms plugin before 3.4.24.2 for WordPress allows CSRF with resultant XSS...
CVE-2020-12354
Incorrect default permissions in WindowsR installer in IntelR AMT SDK versions before 14.0.0.1 may allow an authenticated user to potentially enable escalation of privilege via local access...
CVE-2020-12651
SecureCRT before 8.7.2 allows remote attackers to execute arbitrary code via an Integer Overflow and a Buffer Overflow because a banner can trigger a line number to CSI functions that exceeds INTMAX...
CVE-2020-12033
In Rockwell Automation FactoryTalk Services Platform, all versions, the redundancy host service RdcyHost.exe does not validate supplied identifiers, which could allow an unauthenticated, adjacent attacker to execute remote COM objects with elevated privileges...
CVE-2020-12312
Improper buffer restrictions in the IntelR StratixR 10 FPGA firmware provided with the IntelR QuartusR Prime Pro software before version 20.2 may allow an unauthenticated user to potentially enable escalation of privilege via physical access...
CVE-2020-12330
Improper permissions in the installer for the IntelR Falcon 8+ UAS AscTec Thermal Viewer, all versions, may allow an authenticated user to potentially enable escalation of privilege via local access...
CVE-2020-12132
Fifthplay S.A.M.I before 2019.3HP2 allows unauthenticated stored XSS via a POST request...
CVE-2020-12024
Baxter ExactaMix EM 2400 versions 1.10, 1.11, 1.13, 1.14 and ExactaMix EM1200 Versions 1.1, 1.2, 1.4 and 1.5 does not restrict access to the USB interface from an unauthorized user with physical access. Successful exploitation of this vulnerability may allow an attacker with physical access to th...
CVE-2020-12859
Unnecessary fields in the OpenTrace/BlueTrace protocol in COVIDSafe through v1.0.17 allow a remote attacker to identify a device model by observing cleartext payload data. This allows re-identification of devices, especially less common phone models or those in low-density situations...
CVE-2020-12042
Opto 22 SoftPAC Project Version 9.6 and prior. Paths specified within the zip files used to update the SoftPAC firmware are not sanitized. As a result, an attacker with user privileges can gain arbitrary file write access with system access...
CVE-2020-12141
An out-of-bounds read in the SNMP stack in Contiki-NG 4.4 and earlier allows an attacker to cause a denial of service and potentially disclose information via crafted SNMP packets to snmpberdecodestringlenbuffer in os/net/app-layer/snmp/snmp-ber.c...
CVE-2020-12679
A reflected cross-site scripting XSS vulnerability in the Mitel ShoreTel Conference Web Application 19.50.1000.0 before MiVoice Connect 18.7 SP2 allows remote attackers to inject arbitrary JavaScript and HTML via the PATHINFO to home.php...
CVE-2020-12743
An issue was discovered in Gazie 7.32. A successful installation does not remove or block or in any other way prevent use of its own file /setup/install/setup.php, meaning that anyone can request it without authentication. This file allows arbitrary PHP file inclusion via a hiddenreq POST paramet...
CVE-2020-12303
Use after free in DAL subsystem for IntelR CSME versions before 11.8.80, 11.12.80, 11.22.80, 12.0.70, 13.0.40, 13.30.10, 14.0.45 and 14.5.25, IntelR TXE 3.1.80, 4.0.30 may allow an authenticated user to potentially enable escalation of privileges via local access...