65722 matches found
Rockwell Automation Allen-Bradley MicroLogix 1400 Controllers Buffer Copy Without Checking Size of Input (CVE-2017-16740)
A Buffer Overflow issue was discovered in Rockwell Automation Allen- Bradley MicroLogix 1400 Controllers, Series B and C Versions 21.002 and earlier. The stack-based buffer overflow vulnerability has been identified, which may allow remote code execution. This plugin only works with Tenable.ot...
Rockwell Automation MicroLogix Improper Authentication (CVE-2017-12090)
An exploitable denial of service vulnerability exists in the processing of snmp-set commands of the Allen Bradley Micrologix 1400 Series B FRN 21.2 and below. A specially crafted snmp-set request, when sent without associated firmware flashing snmp-set commands, can cause a device power cycle...
Rockwell Automation Micrologix Improper Access Control (CVE-2017-14466)
An exploitable access control vulnerability exists in the data, program, and function file permissions functionality of Allen Bradley Micrologix 1400 Series B FRN 21.2 and before. A specially crafted packet can cause a read or write operation resulting in disclosure of sensitive information,...
Schneider Electric Modicon M221 PLCs and SoMachine Basic Protection Mechanism Failure (CVE-2017-7575)
Schneider Electric Modicon TM221CE16R 1.3.3.3 devices allow remote attackers to discover the application-protection password via a \x00\x01\x00\x00\x00\x05\x01\x5a\x00\x03\x00 request to the Modbus port 502/tcp. Subsequently the application may be arbitrarily downloaded, modified, and uploaded...
Rockwell Automation Allen-Bradley MicroLogix 1100 and 1400 Exposure of Sensitive Information to an Unauthorized Actor (CVE-2017-7899)
An Information Exposure issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 programmable-logic controllers 1763-L16AWA, Series A and B, Version 16.00 and prior versions; 1763-L16BBB, Series A and B, Version 16.00 and prior versions; 1763-L16BWA, Series A and B, Version 16.00...
Saia Burgess Controls PCD Controllers Exposure of Sensitive Information to an Unauthorized Actor (CVE-2017-9628)
An Information Exposure issue was discovered in Saia Burgess Controls PCD Controllers with PCD firmware versions prior to 1.28.16 or 1.24.69. In certain circumstances, the device pads Ethernet frames with memory contents. This plugin only works with Tenable.ot. Please visit...
Schweitzer Engineering Laboratories, Inc. SEL-3620 and SEL-3622 Improper Access Control (CVE-2017-7928)
An Improper Access Control issue was discovered in Schweitzer Engineering Laboratories SEL SEL-3620 and SEL-3622 Security Gateway Versions R202 and, R203, R203-V1, R203-V2 and, R204, R204-V1. The device does not properly enforce access control while configured for NAT port forwarding, which may...
Rockwell Automation Micrologix Improper Access Control (CVE-2017-14473)
An exploitable access control vulnerability exists in the data, program, and function file permissions functionality of Allen Bradley Micrologix 1400 Series B FRN 21.2 and before. A specially crafted packet can cause a read or write operation resulting in disclosure of sensitive information,...
Rockwell Automation Micrologix Improper Access Control (CVE-2017-14472)
An exploitable access control vulnerability exists in the data, program, and function file permissions functionality of Allen Bradley Micrologix 1400 Series B FRN 21.2 and before. A specially crafted packet can cause a read or write operation resulting in disclosure of sensitive information,...
Schneider Electric Modicon M221 PLCs and SoMachine Basic Use of Hard-Coded Cryptographic Key (CVE-2017-7574)
Schneider Electric SoMachine Basic 1.4 SP1 and Schneider Electric Modicon TM221CE16R 1.3.3.3 devices have a hardcoded- key vulnerability. The Project Protection feature is used to prevent unauthorized users from opening an XML protected project file, by prompting the user for a password. This XML...
Rockwell Automation Allen-Bradley MicroLogix 1100 and 1400 Weak Password Requirements (CVE-2017-7903)
A Weak Password Requirements issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 programmable- logic controllers 1763-L16AWA, Series A and B, Version 16.00 and prior versions; 1763-L16BBB, Series A and B, Version 16.00 and prior versions; 1763-L16BWA, Series A and B, Version...
Rockwell Automation MicroLogix 1100 Controllers Improper Input Validation (CVE-2017-7924)
An Improper Input Validation issue was discovered in Rockwell Automation MicroLogix 1100 controllers 1763-L16BWA, 1763-L16AWA, 1763-L16BBB, and 1763-L16DWD. A remote, unauthenticated attacker could send a single, specially crafted Programmable Controller Communication Commands PCCC packet to the...
Siemens BACnet Field Panels Authentication Bypass Using an Alternate Path or Channel (CVE-2017-9946)
A vulnerability has been identified in Siemens APOGEE PXC and TALON TC BACnet Automation Controllers in all versions V3.5. An attacker with network access to the integrated web server 80/tcp and 443/tcp could bypass the authentication and download sensitive information from the device. This plugi...
Siemens PROFINET DCP Uncontrolled Resource Consumption (CVE-2017-2681)
Specially crafted PROFINET DCP packets sent on a local Ethernet segment Layer 2 to an affected product could cause a denial of service condition of that product. Human interaction is required to recover the system. PROFIBUS interfaces are not affected. This plugin only works with Tenable.ot. Plea...
Rockwell Automation Allen-Bradley CompactLogix and Compact GuardLogix Improper Input Validation (CVE-2017-9312)
Improperly implemented option-field processing in the TCP/IP stack on Allen-Bradley L30ERMS safety devices v30 and earlier causes a denial of service. When a crafted TCP packet is received, the device reboots immediately. This plugin only works with Tenable.ot. Please visit...
Rockwell Automation Allen-Bradley MicroLogix 1100 and 1400 Reusing a Nonce, Key Pair in Encryption (CVE-2017-7902)
A Reusing a Nonce, Key Pair in Encryption issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 programmable-logic controllers 1763-L16AWA, Series A and B, Version 16.00 and prior versions; 1763-L16BBB, Series A and B, Version 16.00 and prior versions; 1763-L16BWA, Series A an...
Beckhoff ADS Protocol Inadequate Encryption Strength (CVE-2017-16726)
Beckhoff TwinCAT supports communication over ADS. ADS is a protocol for industrial automation in protected environments. ADS has not been designed to achieve security purposes and therefore does not include any encryption algorithms because of their negative effect on performance and throughput. ...
Beckhoff ADS Router Use of a Broken or Risky Cryptographic Algorithm (CVE-2017-16718)
Beckhoff TwinCAT 3 supports communication over ADS. ADS is a protocol for industrial automation in protected environments. This protocol uses user configured routes, that can be edited remotely via ADS. This special command supports encrypted authentication with username/password. The encryption...
Rockwell Automation Micrologix Improper Access Control (CVE-2017-14467)
An exploitable access control vulnerability exists in the data, program, and function file permissions functionality of Allen Bradley Micrologix 1400 Series B FRN 21.2 and before. A specially crafted packet can cause a read or write operation resulting in disclosure of sensitive information,...
Debian: Security Advisory (DLA-2910-1)
The remote host is missing an update for the Debian SPDX-FileCopyrightText: 2022 Greenbone AG Some text descriptions might be excerpted from a referenced sources, and are Copyright C by the respective right holders. SPDX-License-Identifier: GPL-2.0-only ifdescription...