Lucene search
K

7 matches found

Circl
Circl
added 2025/07/24 11:35 p.m.1 views

CVE-2014-8514

creationtimestamp| type| source ---|---|--- 2025-07-24 23:35:46+00:00| seen| Telegram/P4Fx1e4brLs0o50aOl3IKCUGzYxzeKJbGJmygAKRXq-qUJ0...

7.5CVSS4.8AI score0.04003EPSS
Exploits0
NVD
NVD
added 2014/12/27 3:59 p.m.36 views

CVE-2014-8514

Buffer overflow in an ActiveX control in MDraw30.ocx in Schneider Electric ProClima before 6.1.7 allows remote attackers to execute arbitrary code via unspecified vectors, a different vulnerability than CVE-2014-8513 and CVE-2014-9188. NOTE: this may be clarified later based on details provided b...

7.5CVSS7.7AI score0.04003EPSS
Exploits0References3
Prion
Prion
added 2014/12/27 3:59 p.m.24 views

Buffer overflow

Buffer overflow in an ActiveX control in MDraw30.ocx in Schneider Electric ProClima before 6.1.7 allows remote attackers to execute arbitrary code via unspecified vectors, a different vulnerability than CVE-2014-8514 and CVE-2014-9188. NOTE: this may be clarified later based on details provided b...

7.5CVSS8.2AI score0.06121EPSS
Exploits0References2Affected Software1
Prion
Prion
added 2014/12/27 3:59 p.m.14 views

Buffer overflow

Buffer overflow in an ActiveX control in MDraw30.ocx in Schneider Electric ProClima before 6.1.7 allows remote attackers to execute arbitrary code via unspecified vectors, a different vulnerability than CVE-2014-8513 and CVE-2014-8514. NOTE: this may be clarified later based on details provided b...

9CVSS8.2AI score0.06121EPSS
Exploits0References2Affected Software1
CVE
CVE
added 2014/12/27 3:0 p.m.56 views

CVE-2014-8514

Schneider Electric ProClima (MDraw30.ocx ActiveX control) has a buffer overflow vulnerability in versions before 6.1.7, allowing remote code execution via unspecified vectors. This CVE is linked to the ProClima family; no exploit details are provided here. Upgrade to 6.1.7 or later to mitigate.

7.5CVSS7.9AI score0.04003EPSS
Exploits0References3Affected Software1
Cvelist
Cvelist
added 2014/12/27 3:0 p.m.38 views

CVE-2014-8514

Buffer overflow in an ActiveX control in MDraw30.ocx in Schneider Electric ProClima before 6.1.7 allows remote attackers to execute arbitrary code via unspecified vectors, a different vulnerability than CVE-2014-8513 and CVE-2014-9188. NOTE: this may be clarified later based on details provided b...

7.7AI score0.04003EPSS
Exploits0References3
ICS
ICS
added 2014/09/18 6:0 a.m.66 views

Schneider Electric ProClima Command Injection Vulnerabilities

OVERVIEW NCCIC/ICS-CERT received a report from HP’s Zero Day Initiative ZDI concerning command injection vulnerabilities in Schneider Electric’s ProClima software package. These vulnerabilities were reported to ZDI by security researchers Ariele Caltabiano, Andrea Micalizzi, and Brian Gorenc...

10CVSS7.7AI score0.04436EPSS
Exploits0References10