CVE-2020-1811
Summary: CVE-2020-1811 affects Huawei GaussDB 200 OLAP, version 6.5.1, where a vulnerability arises from insufficient input validation leading to a command-injection risk. The condition allows remote attackers with low privileges to send crafted commands to the affected GaussDB 200 device and pot...
CVE-2020-1811
GaussDB 200 with version of 6.5.1 have a command injection vulnerability. Due to insufficient input validation, remote attackers with low permissions could exploit this vulnerability by sending crafted commands to the affected device. Successful exploit could allow an attacker to execute commands...
CVE-2020-1853
GaussDB 200 with version of 6.5.1 have a path traversal vulnerability. Due to insufficient input path validation, an authenticated attacker can traverse directories and download files to a specific directory. Successful exploit may cause information leakage...
CVE-2020-1853
GaussDB 200 with version of 6.5.1 have a path traversal vulnerability. Due to insufficient input path validation, an authenticated attacker can traverse directories and download files to a specific directory. Successful exploit may cause information leakage...
Path traversal
GaussDB 200 with version of 6.5.1 have a path traversal vulnerability. Due to insufficient input path validation, an authenticated attacker can traverse directories and download files to a specific directory. Successful exploit may cause information leakage...
CVE-2020-1853
Summary (CVE-2020-1853) : Huawei GaussDB 200 OLAP 6.5.1 is affected by a path traversal vulnerability caused by insufficient input path validation. An authenticated attacker can traverse directories and download files to a target directory, leading to information leakage. This issue is documented...
CVE-2020-1853
GaussDB 200 with version of 6.5.1 have a path traversal vulnerability. Due to insufficient input path validation, an authenticated attacker can traverse directories and download files to a specific directory. Successful exploit may cause information leakage...
Multiple Siemens Products Resource Management Error Vulnerability
Siemens SCALANCE X-200IRT and SCALANCE XB-200 are both products of Siemens, Germany.SCALANCE X-200IRT is an industrial grade Ethernet switch.SCALANCE XB-200 is a managed industrial Ethernet switch. A resource management error vulnerability exists in multiple Siemens products, where a program fail...
Design/Logic Flaw
A vulnerability has been identified in SCALANCE S602 All versions V4.1, SCALANCE S612 All versions V4.1, SCALANCE S623 All versions V4.1, SCALANCE S627-2M All versions V4.1, SCALANCE X-200 switch family incl. SIPLUS NET variants All versions 5.2.4, SCALANCE X-200IRT switch family incl. SIPLUS NET...
CVE-2019-13924
CVE-2019-13924 affects Siemens SCALANCE X and S switches. The root issue is that the admin web interface does not send the X-Frame-Options header, enabling clickjacking where an attacker could trick a logged-in administrator into performing actions via a malicious page. Affected families and vers...
PT-2020-9414 · Siemens · Scalance X-200Irt Switch Family +5
Name of the Vulnerable Software and Affected Versions: SCALANCE S602 versions prior to V4.1 SCALANCE S612 versions prior to V4.1 SCALANCE S623 versions prior to V4.1 SCALANCE S627-2M versions prior to V4.1 SCALANCE X-200 switch family versions prior to 5.2.4 SCALANCE X-200IRT switch family versio...
The vulnerability of Siemens industrial switches Siemens SCALANCE X-200, SCALANCE X-200IRT, and SCALANCE X-300 allows attackers to execute cross-site scripting attacks (XSS).
The vulnerability of Siemens industrial switches SCalance X-200, SCALANCE X-200IRT, and SCALANCE X-300 relates to the lack of measures taken to protect the website structure. Exploiting this vulnerability allows a malicious actor to perform cross-site scripting attacks XSS remotely...
CVE-2020-6964
The CVE-2020-6964 entry corresponds to GE Healthcare vulnerabilities affecting CARESCAPE Telemetry Server, ApexPro Telemetry Server, CIC, and CSCS (and related monitor endpoints) where the integrated service for keyboard switching could allow attackers to obtain remote keyboard input access witho...
Security Advisory - Command Injection Vulnerability in GaussDB 200
There is a command injection vulnerability in GaussDB 200. The software constructs part of a command using external input from users, but the software does not sufficiently validate the user input. Successful exploit could allow the attacker to inject certain commands. Vulnerability ID:...
[SECURITY] Fedora 31 Update: kernel-5.4.12-200.fc31
The kernel meta package...
Security Advisory - Command Injection Vulnerability in GaussDB 200 Product
There is a command injection vulnerability in GaussDB 200 product. Due to insufficient input validation, remote attackers with low permissions could exploit this vulnerability by sending crafted commands to the affected device. Successful exploit could allow an attacker to execute commands...
Huawei GaussDB 200 Command Injection Vulnerability
Huawei GaussDB 200 is a distributed parallel relational database system developed by Huawei China based on the open source database Postgres-XC. A command injection vulnerability exists in Huawei GaussDB 200 version 6.5.1, which arises from a program that fails to adequately perform input...
SIEMENS SIMATIC S7-200 Smart suffers from weak password vulnerability
Siemens is a leading global technology company providing solutions for customers in the areas of power generation and transmission and distribution, infrastructure, industrial automation, drives and software through innovations in electrification, automation and digitalization. A weak password...
WAGO PFC 200 'I/O-Check' Buffer Overflow Vulnerability
The WAGO PFC 200 and WAGO PFC 100 are both programmable logic controllers PLCs from WAGO Germany. A buffer overflow vulnerability exists in the 'I/O-Check' function in the WAGO PFC 200 and PFC100. The vulnerability originates when a networked system or product performs an operation on memory...
EulerOS 2.0 SP5 : NetworkManager (EulerOS-SA-2019-2698)
According to the version of the NetworkManager packages installed, the EulerOS installation on the remote host is affected by the following vulnerability : - GNOME NetworkManager version 1.10.2 and earlier contains a Information Exposure CWE-200 vulnerability in DNS resolver that can result in...