CVE-2023-22611
A CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists that could cause information disclosure when specific messages are sent to the server over the database server TCP port. Affected Products: EcoStruxure Geo SCADA Expert 2019 - 2021 formerly known as...
CVE-2023-22611
A CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists that could cause information disclosure when specific messages are sent to the server over the database server TCP port. Affected Products: EcoStruxure Geo SCADA Expert 2019 - 2021 formerly known as...
CVE-2023-22611
CVE-2023-22611 describes an information disclosure vulnerability (CWE-200) in EcoStruxure Geo SCADA Expert 2019–2021 (formerly ClearSCADA) where sensitive data could be exposed via specific messages sent to the database server TCP port. The CVSSv3.1 vector (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N) yi...
Siemens SCALANCE X-200 switches Insufficient Entropy Source (CVE-2013-5709)
The authentication implementation in the web server on Siemens SCALANCE X-200 switches with firmware before 5.0.0 does not use a sufficient source of entropy for generating values of random numbers, which makes it easier for remote attackers to hijack sessions by predicting a value. This plugin...
Siemens SCALANCE X Products Heap-Based Buffer Overflow (CVE-2020-25226)
A vulnerability has been identified in SCALANCE X-200 switch family incl. SIPLUS NET variants All versions V5.2.5, SCALANCE X-200IRT switch family incl. SIPLUS NET variants All versions V5.5.0. The web server of the affected devices contains a vulnerability that may lead to a buffer overflow...
Siemens SCALANCE X-200 and X-200IRT Families Improper Neutralization of Input During Web Page Generation (CVE-2022-40631)
A vulnerability has been identified in SCALANCE X200-4P IRT All versions V5.5.0, SCALANCE X201-3P IRT All versions V5.5.0, SCALANCE X201-3P IRT PRO All versions V5.5.0, SCALANCE X202-2IRT All versions V5.5.0, SCALANCE X202-2P IRT All versions V5.5.0, SCALANCE X202-2P IRT PRO All versions V5.5.0,...
Siemens SCALANCE X Products Missing Authentication For Critical Function (CVE-2020-15799)
A vulnerability has been identified in SCALANCE X-200 switch family incl. SIPLUS NET variants All versions V5.2.5, SCALANCE X-200IRT switch family incl. SIPLUS NET variants All versions V5.5.0. The vulnerability could allow an unauthenticated attacker to reboot the device over the network by usin...
Siemens SCALANCE X Switches Use of Hard-Coded Cryptographic Key (CVE-2020-28391)
A vulnerability has been identified in SCALANCE X-200 switch family incl. SIPLUS NET variants All versions V5.2.5, SCALANCE X-200IRT switch family incl. SIPLUS NET variants All versions V5.5.0, SCALANCE X-200RNA switch family All versions V3.2.7. Devices create a new unique key upon factory reset...
Fedora 37 : kernel (2023-0597579983)
The remote Fedora 37 host has a package installed that is affected by multiple vulnerabilities as referenced in the FEDORA-2023-0597579983 advisory. The 6.1.7 stable kernel update contains a number of important fixes across the tree. Tenable has extracted the preceding description block directly...
JVN#72418815: Pgpool-II vulnerable to information disclosure
Pgpool-II is cluster management tool. Pgpool-II contains an information disclosure vulnerability CWE-200 in its watchdog function. Note that, only systems that meet all of the following setting requirements are affected by this vulnerability. Watchdog function is enabled usewatchdog = on "query...
Design/Logic Flaw
SAUTER Controls Nova 200–220 Series with firmware version 3.3-006 and prior and BACnetstac version 4.2.1 and prior allows the execution of commands without credentials. As Telnet and file transfer protocol FTP are the only protocols available for device management, an unauthorized user could acce...
CVE-2023-0052
SAUTER Controls Nova 200–220 Series (firmware 3.3-006 and earlier) and BACnetstac 4.2.1 and earlier are affected by CVE-2023-0052 due to missing authentication for a critical function, allowing command execution without credentials. Telemetry shows Telnet and FTP are the only device-management pr...
CVE-2023-0052 SAUTER Controls Nova 200–220 Series Missing Authentication for Critical Function
SAUTER Controls Nova 200–220 Series with firmware version 3.3-006 and prior and BACnetstac version 4.2.1 and prior allows the execution of commands without credentials. As Telnet and file transfer protocol FTP are the only protocols available for device management, an unauthorized user could acce...
CVE-2020-22655
In Ruckus R310 10.5.1.0.199, Ruckus R500 10.5.1.0.199, Ruckus R600 10.5.1.0.199, Ruckus T300 10.5.1.0.199, Ruckus T301n 10.5.1.0.199, Ruckus T301s 10.5.1.0.199, SmartCell Gateway 200 SCG200 before 3.6.2.0.795, SmartZone 100 SZ-100 before 3.6.2.0.795, SmartZone 300 SZ300 before 3.6.2.0.795, Virtua...
CVE-2020-22656
In Ruckus R310 10.5.1.0.199, Ruckus R500 10.5.1.0.199, Ruckus R600 10.5.1.0.199, Ruckus T300 10.5.1.0.199, Ruckus T301n 10.5.1.0.199, Ruckus T301s 10.5.1.0.199, SmartCell Gateway 200 SCG200 before 3.6.2.0.795, SmartZone 100 SZ-100 before 3.6.2.0.795, SmartZone 300 SZ300 before 3.6.2.0.795, Virtua...
CVE-2020-22658
In Ruckus R310 10.5.1.0.199, Ruckus R500 10.5.1.0.199, Ruckus R600 10.5.1.0.199, Ruckus T300 10.5.1.0.199, Ruckus T301n 10.5.1.0.199, Ruckus T301s 10.5.1.0.199, SmartCell Gateway 200 SCG200 before 3.6.2.0.795, SmartZone 100 SZ-100 before 3.6.2.0.795, SmartZone 300 SZ300 before 3.6.2.0.795, Virtua...
CVE-2020-22657
In Ruckus R310 10.5.1.0.199, Ruckus R500 10.5.1.0.199, Ruckus R600 10.5.1.0.199, Ruckus T300 10.5.1.0.199, Ruckus T301n 10.5.1.0.199, Ruckus T301s 10.5.1.0.199, SmartCell Gateway 200 SCG200 before 3.6.2.0.795, SmartZone 100 SZ-100 before 3.6.2.0.795, SmartZone 300 SZ300 before 3.6.2.0.795, Virtua...
Code injection
In Ruckus R310 10.5.1.0.199, Ruckus R500 10.5.1.0.199, Ruckus R600 10.5.1.0.199, Ruckus T300 10.5.1.0.199, Ruckus T301n 10.5.1.0.199, Ruckus T301s 10.5.1.0.199, SmartCell Gateway 200 SCG200 before 3.6.2.0.795, SmartZone 100 SZ-100 before 3.6.2.0.795, SmartZone 300 SZ300 before 3.6.2.0.795, Virtua...
PT-2023-11633 · Ruckus · Smartcell Gateway 200 +12
Name of the Vulnerable Software and Affected Versions: Ruckus R310 version 10.5.1.0.199 Ruckus R500 version 10.5.1.0.199 Ruckus R600 version 10.5.1.0.199 Ruckus T300 version 10.5.1.0.199 Ruckus T301n version 10.5.1.0.199 Ruckus T301s version 10.5.1.0.199 SmartCell Gateway 200 SCG200 versions prio...
PT-2023-11631 · Ruckus · Smartcell Gateway 200 +12
Name of the Vulnerable Software and Affected Versions: Ruckus R310 version 10.5.1.0.199 Ruckus R500 version 10.5.1.0.199 Ruckus R600 version 10.5.1.0.199 Ruckus T300 version 10.5.1.0.199 Ruckus T301n version 10.5.1.0.199 Ruckus T301s version 10.5.1.0.199 SmartCell Gateway 200 SCG200 versions prio...