1261 matches found
CVE-2023-23458 Sunell DVR – Exposure of Sensitive Information
Sunell DVR, latest version, CWE-200: Exposure of Sensitive Information to an Unauthorized Actor through an unspecified request...
CVE-2023-23458
Sunell DVR (latest version) is affected by CVE-2023-23458, which involves CWE-200: Exposure of Sensitive Information to an Unauthorized Actor from an unspecified request. The NVD entry documents a network-accessible issue with low attack complexity and low privileges required, leading to potentia...
CVE-2023-23458 Sunell DVR – Exposure of Sensitive Information
Sunell DVR, latest version, CWE-200: Exposure of Sensitive Information to an Unauthorized Actor through an unspecified request...
WAGO I/O-CHECK Missing Authentication For Critical Function (CVE-2019-5077)
An exploitable denial-of-service vulnerability exists in the iocheckd service 'I/O-Chec'' functionality of WAGO PFC 200 Firmware versions 03.01.0713 and 03.00.3912, and WAGO PFC 100 Firmware version 03.00.3912. A specially crafted set of packets can cause a denial of service, resulting in the...
Wago PFC200 iocheckd service 'I/O-Check' cache Code Execution (CVE-2019-5181)
An exploitable stack buffer overflow vulnerability vulnerability exists in the iocheckd service I/O-Check' functionality of WAGO PFC 200 Firmware version 03.02.0214. A specially crafted XML cache file written to a specific location on the device can cause a stack buffer overflow, resulting in cod...
Wago PFC200 iocheckd service 'I/O-Check' cache DNS code execution vulnerability (CVE-2019-5166)
An exploitable stack buffer overflow vulnerability exists in the iocheckd service I/O-Check' functionality of WAGO PFC 200 version 03.02.0214. A specially crafted XML cache file written to a specific location on the device can cause a stack buffer overflow, resulting in code execution. An attacke...
Wago PFC200 iocheckd service 'I/O-Check' cache Code Execution (CVE-2019-5178)
An exploitable stack buffer overflow vulnerability vulnerability exists in the iocheckd service I/O-Check' functionality of WAGO PFC 200 Firmware version 03.02.0214. An attacker can send a specially crafted packet to trigger the parsing of this cache file. The destination buffer sp+0x440 is...
Wago PFC200 iocheckd service 'I/O-Check' cache Command Injection (CVE-2019-5167)
An exploitable command injection vulnerability exists in the iocheckd service I/O-Check' function of the WAGO PFC 200 version 03.02.0214. At 0x1e3f0 the extracted dns value from the xml file is used as an argument to /etc/config-tools/editdnsserver %s dns-server-nr=%d dns- server-name= using...
Wago PFC 200 Web-Based Management Code Execution (CVE-2020-6090)
An exploitable code execution vulnerability exists in the Web-Based Management WBM functionality of WAGO PFC 200 03.03.1015. A specially crafted series of HTTP requests can cause code execution resulting in remote code execution. An attacker can make an authenticated HTTP request to trigger this...
CVE-2021-37492
An issue discovered in src/wallet/wallet.cpp in Ravencoin Core 4.3.2.1 and earlier allows attackers to view sensitive information via CWallet::CreateTransactionAll function...
[SECURITY] Fedora 37 Update: kernel-6.1.9-200.fc37
The kernel meta package...
Information disclosure
A CWE-200: Information Exposure vulnerability exists that could cause the exposure of sensitive information stored on the memory of the controller when communicating over the Modbus TCP protocol. Affected Products: Modicon M340 CPU part numbers BMXP34 Versions prior to V3.30, Modicon M580 CPU par...
CVE-2021-22786
Schneider Electric CVE-2021-22786 is an information-exposure vulnerability in Modicon controllers over Modbus TCP. Affected products/versions: Modicon M340 CPU (BMXP34*) prior to V3.30, M580 CPU (BMEP*/BMEH*) prior to SV3.20, MC80 (BMKC80) prior to V1.6, M580 Safety (BMEP58*/BMEH58*) all versions...
CVE-2023-22611
A CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists that could cause information disclosure when specific messages are sent to the server over the database server TCP port. Affected Products: EcoStruxure Geo SCADA Expert 2019 - 2021 formerly known as...
CVE-2023-22611
CVE-2023-22611 describes an information disclosure vulnerability (CWE-200) in EcoStruxure Geo SCADA Expert 2019–2021 (formerly ClearSCADA) where sensitive data could be exposed via specific messages sent to the database server TCP port. The CVSSv3.1 vector (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N) yi...
CVE-2023-22611
A CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists that could cause information disclosure when specific messages are sent to the server over the database server TCP port. Affected Products: EcoStruxure Geo SCADA Expert 2019 - 2021 formerly known as...
Siemens SCALANCE X-200 switches Insufficient Entropy Source (CVE-2013-5709)
The authentication implementation in the web server on Siemens SCALANCE X-200 switches with firmware before 5.0.0 does not use a sufficient source of entropy for generating values of random numbers, which makes it easier for remote attackers to hijack sessions by predicting a value. This plugin...
Siemens SCALANCE X Products Missing Authentication For Critical Function (CVE-2020-15799)
A vulnerability has been identified in SCALANCE X-200 switch family incl. SIPLUS NET variants All versions V5.2.5, SCALANCE X-200IRT switch family incl. SIPLUS NET variants All versions V5.5.0. The vulnerability could allow an unauthenticated attacker to reboot the device over the network by usin...
Siemens SCALANCE X-200 and X-200IRT Families Improper Neutralization of Input During Web Page Generation (CVE-2022-40631)
A vulnerability has been identified in SCALANCE X200-4P IRT All versions V5.5.0, SCALANCE X201-3P IRT All versions V5.5.0, SCALANCE X201-3P IRT PRO All versions V5.5.0, SCALANCE X202-2IRT All versions V5.5.0, SCALANCE X202-2P IRT All versions V5.5.0, SCALANCE X202-2P IRT PRO All versions V5.5.0,...
Siemens SCALANCE X Switches Use of Hard-Coded Cryptographic Key (CVE-2020-28391)
A vulnerability has been identified in SCALANCE X-200 switch family incl. SIPLUS NET variants All versions V5.2.5, SCALANCE X-200IRT switch family incl. SIPLUS NET variants All versions V5.5.0, SCALANCE X-200RNA switch family All versions V3.2.7. Devices create a new unique key upon factory reset...