108 matches found
Information disclosure
A vulnerability has been identified in NX 1953 Series All versions V1973.3700, NX 1980 Series All versions V1988, Solid Edge SE2021 All versions SE2021MP8. The affected application is vulnerable to information disclosure by unexpected access to an uninitialized pointer while parsing user-supplied...
Design/Logic Flaw
A vulnerability has been identified in NX 1953 Series All versions V1973.3700, NX 1980 Series All versions V1988, Solid Edge SE2021 All versions SE2021MP8. The affected application contains a use-after-free vulnerability while parsing OBJ files. An attacker could leverage this vulnerability to...
Out-of-bounds
A vulnerability has been identified in NX 1980 Series All versions V1984, Solid Edge SE2021 All versions SE2021MP8. The affected application is vulnerable to an out of bounds read past the end of an allocated buffer when parsing JT files. An attacker could leverage this vulnerability to leak...
CVE-2021-41538
A vulnerability has been identified in NX 1953 Series All versions V1973.3700, NX 1980 Series All versions V1988, Solid Edge SE2021 All versions SE2021MP8. The affected application is vulnerable to information disclosure by unexpected access to an uninitialized pointer while parsing user-supplied...
CVE-2021-41538
CVE-2021-41538 : Siemens Solid Edge/NX OBJ parsing uninitialized pointer information disclosure. Affected products and versions include: NX 1953 Series (all versions < V1973.3700) and NX 1980 Series (all versions < V1988); Solid Edge SE2021 (all versions = V1973.3700, NX 1980 >= V1988, a...
CVE-2021-41535
A vulnerability has been identified in NX 1953 Series All versions V1973.3700, NX 1980 Series All versions V1988, Solid Edge SE2021 All versions SE2021MP8. The affected application contains a use-after-free vulnerability while parsing OBJ files. An attacker could leverage this vulnerability to...
CVE-2021-41535
Siemens Siemens NX 1953 Series (before v1973.3700), NX 1980 Series (before v1988), and Solid Edge SE2021 (before SE2021MP8) have a use-after-free vulnerability in OBJ file parsing that could allow code execution in the current process (ZDI-CAN-13771). Public disclosures (ZDI-21-1119, RH Red Hat a...
CVE-2021-41534
A vulnerability has been identified in NX 1980 Series All versions V1984, Solid Edge SE2021 All versions SE2021MP8. The affected application is vulnerable to an out of bounds read past the end of an allocated buffer when parsing JT files. An attacker could leverage this vulnerability to leak...
CVE-2021-41534
CVE-2021-41534 affects Siemens NX 1980 Series (all versions before v1984) and Solid Edge SE2021 (all versions before SE2021MP8). Root cause: an out-of-bounds read past the end of an allocated buffer during JT file parsing, leading to potential information disclosure within the process. Mitigation...
CVE-2021-41533
Siemens NX 1980 Series and Solid Edge SE2021 are affected by CVE-2021-41533 due to an out-of-bounds read when parsing JT files, enabling potential information disclosure within the current process. Siemens fixes are available: update NX 1980 Series to v1984+ and SE2021 to SE2021MP8+. The issue wa...
CVE-2021-41533
A vulnerability has been identified in NX 1980 Series All versions V1984, Solid Edge SE2021 All versions SE2021MP8. The affected application is vulnerable to an out of bounds read past the end of an allocated buffer when parsing JT files. An attacker could leverage this vulnerability to leak...
CVE-2021-37202
A vulnerability has been identified in NX 1980 Series All versions V1984, Solid Edge SE2021 All versions SE2021MP8. The IFC adapter in affected application contains a use-after-free vulnerability that could be triggered while parsing user-supplied IFC files. An attacker could leverage this...
CVE-2021-37202
A vulnerability has been identified in NX 1980 Series All versions V1984, Solid Edge SE2021 All versions SE2021MP8. The IFC adapter in affected application contains a use-after-free vulnerability that could be triggered while parsing user-supplied IFC files. An attacker could leverage this...
CVE-2021-37203
A vulnerability has been identified in NX 1980 Series All versions V1984, Solid Edge SE2021 All versions SE2021MP8. The plmxmlAdapterIFC.dll contains an out-of-bounds read while parsing user supplied IFC files which could result in a read past the end of an allocated buffer. This could allow an...
CVE-2021-37203
A vulnerability has been identified in NX 1980 Series All versions V1984, Solid Edge SE2021 All versions SE2021MP8. The plmxmlAdapterIFC.dll contains an out-of-bounds read while parsing user supplied IFC files which could result in a read past the end of an allocated buffer. This could allow an...
Design/Logic Flaw
A vulnerability has been identified in NX 1980 Series All versions V1984, Solid Edge SE2021 All versions SE2021MP8. The plmxmlAdapterIFC.dll contains an out-of-bounds read while parsing user supplied IFC files which could result in a read past the end of an allocated buffer. This could allow an...
Design/Logic Flaw
A vulnerability has been identified in NX 1980 Series All versions V1984, Solid Edge SE2021 All versions SE2021MP8. The IFC adapter in affected application contains a use-after-free vulnerability that could be triggered while parsing user-supplied IFC files. An attacker could leverage this...
CVE-2021-37203
A vulnerability has been identified in NX 1980 Series All versions V1984, Solid Edge SE2021 All versions SE2021MP8. The plmxmlAdapterIFC.dll contains an out-of-bounds read while parsing user supplied IFC files which could result in a read past the end of an allocated buffer. This could allow an...
CVE-2021-37203
CVE-2021-37203 concerns Siemens NX/NX 1980 Series and Solid Edge SE2021 where the plmxmlAdapterIFC.dll performs an out-of-bounds read while parsing user-supplied IFC files. This can cause a denial-of-service or memory information leakage. Affected: NX 1980 Series (all versions before V1984) and S...
CVE-2021-37202
Siemens NX 1980 Series (all versions before v1984) and Solid Edge SE2021 (before SE2021MP8) are affected by CVE-2021-37202 due to a use-after-free vulnerability in the IFC adapter when parsing user-supplied IFC files. This could allow code execution in the context of the current process. Related ...