Lucene search
+L

14 matches found

osv_cve
osv_cve
•added 2022/02/24 7:15 p.m.•19 views

CVE-2020-14502

The web interface of the 1734-AENTR communication module is vulnerable to stored XSS. A remote, unauthenticated attacker could store a malicious script within the web interface that, when executed, could modify some string values on the homepage of the web interface...

6.1CVSS5.8AI score0.01008EPSS
SaveExploits0References1
NVD
NVD
•added 2022/02/24 7:15 p.m.•24 views

CVE-2020-14504

The web interface of the 1734-AENTR communication module mishandles authentication for HTTP POST requests. A remote, unauthenticated attacker can send a crafted request that may allow for modification of the configuration settings...

5.3CVSS0.01266EPSS
SaveExploits0References1
NVD
NVD
•added 2022/02/24 7:15 p.m.•22 views

CVE-2020-14502

The web interface of the 1734-AENTR communication module is vulnerable to stored XSS. A remote, unauthenticated attacker could store a malicious script within the web interface that, when executed, could modify some string values on the homepage of the web interface...

6.1CVSS0.01008EPSS
SaveExploits0References1
Prion
Prion
•added 2022/02/24 7:15 p.m.•26 views

Cross site scripting

The web interface of the 1734-AENTR communication module is vulnerable to stored XSS. A remote, unauthenticated attacker could store a malicious script within the web interface that, when executed, could modify some string values on the homepage of the web interface...

4.3CVSS6.1AI score0.01008EPSS
SaveExploits0References1Affected Software2
Prion
Prion
•added 2022/02/24 7:15 p.m.•24 views

Authentication flaw

The web interface of the 1734-AENTR communication module mishandles authentication for HTTP POST requests. A remote, unauthenticated attacker can send a crafted request that may allow for modification of the configuration settings...

5CVSS5.7AI score0.01266EPSS
SaveExploits0References1Affected Software2
Cvelist
Cvelist
•added 2022/02/24 6:26 p.m.•50 views

CVE-2020-14502

The web interface of the 1734-AENTR communication module is vulnerable to stored XSS. A remote, unauthenticated attacker could store a malicious script within the web interface that, when executed, could modify some string values on the homepage of the web interface...

6.2AI score0.01008EPSS
SaveExploits0References1
CVE
CVE
•added 2022/02/24 6:26 p.m.•78 views

CVE-2020-14502

Rockwell Automation 1734-AENTR Series B/C are affected by CVE-2020-14502 due to a stored XSS in the web interface. The vulnerability allows a remote, unauthenticated attacker to store a script that can modify homepage text. Technical details are documented in ICS advisory ICSA-21-063-01, which li...

6.1CVSS6.2AI score0.01008EPSS
SaveExploits0References1Affected Software1
Positive Technologies
Positive Technologies
•added 2022/02/24 12:00 a.m.•6 views

PT-2022-8571

Name of the Vulnerable Software and Affected Versions 1734-AENTR communication module affected versions not specified Description The web interface of the communication module is vulnerable to stored XSS, allowing a remote, unauthenticated attacker to store a malicious script that, when executed,...

6.1CVSS0.01008EPSS
SaveExploits0References4
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2022/02/24 12:00 a.m.•8 views

CVE-2020-14504: Improper Access Control

The web interface of the 1734-AENTR communication module mishandles authentication for HTTP POST requests. A remote, unauthenticated attacker can send a crafted request that may allow for modification of the configuration settings...

5.3CVSS6AI score0.01266EPSS
SaveExploits0References4
Positive Technologies
Positive Technologies
•added 2022/02/24 12:00 a.m.•8 views

PT-2022-8572

Name of the Vulnerable Software and Affected Versions 1734-AENTR communication module affected versions not specified Description The web interface of the 1734-AENTR communication module mishandles authentication for HTTP POST requests, allowing a remote, unauthenticated attacker to send a crafte...

5.3CVSS0.01266EPSS
SaveExploits0References4
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2022/02/24 12:00 a.m.•10 views

CVE-2020-14502: Improper Neutralization of Input During Web Page Generation

The web interface of the 1734-AENTR communication module is vulnerable to stored XSS. A remote, unauthenticated attacker could store a malicious script within the web interface that, when executed, could modify some string values on the homepage of the web interface...

6.1CVSS6.3AI score0.01008EPSS
SaveExploits0References3
CNNVD
CNNVD
•added 2021/03/04 12:00 a.m.•25 views

Rockwell Automation 1734-AENTR Authorization Issue Vulnerability

The Rockwell Automation 1734-AENTR is an industrial device from Rockwell Automation, Inc. It provides an industrial control system. The Rockwell Automation 1734-AENTR suffers from an authorization issue vulnerability that arises from an unauthenticated attacker being able to send a crafted reques...

5.3CVSS5.8AI score0.01266EPSS
SaveExploits0References4
CNNVD
CNNVD
•added 2021/03/04 12:00 a.m.•21 views

Rockwell Automation 1734-AENTR Cross-site Scripting Vulnerability

The Rockwell Automation 1734-AENTR is an industrial device from Rockwell Automation, Inc. It provides an industrial control system. The 1734-AENTR suffers from a cross-site scripting vulnerability that originates in the web interface of the communication module that is susceptible to an attacked...

6.1CVSS6AI score0.01008EPSS
SaveExploits0References4
ICS
ICS
•added 2021/03/04 12:00 a.m.•91 views

Rockwell Automation 1734-AENTR Series B and Series C

1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: Rockwell Automation Equipment: 1734-AENTR Series B and Series C Vulnerabilities: Improper Access Control, Cross-site Scripting 2. RISK EVALUATION Successful exploitation of these vulnerabilities...

6.1CVSS6.5AI score0.01266EPSS
SaveExploits0References5
Rows per page