21 matches found
CVE-2026-24437
Shenzhen Tenda W30E V2 firmware versions up to and including V16.01.0.195037 serve sensitive administrative content without appropriate cache-control directives. As a result, browsers may store credential-bearing responses locally, exposing them to subsequent unauthorized access...
CVE-2026-24436
Shenzhen Tenda W30E V2 firmware versions up to and including V16.01.0.195037 do not enforce rate limiting or account lockout mechanisms on authentication endpoints. This allows attackers to perform unrestricted brute-force attempts against administrative credentials...
CVE-2026-24435
Shenzhen Tenda W30E V2 firmware versions up to and including V16.01.0.195037 implement an insecure Cross-Origin Resource Sharing CORS policy on authenticated administrative endpoints. The device sets Access-Control-Allow-Origin: in combination with Access-Control-Allow-Credentials: true, allowing...
CVE-2026-24436
Shenzhen Tenda W30E V2 firmware versions up to and including V16.01.0.195037 do not enforce rate limiting or account lockout mechanisms on authentication endpoints. This allows attackers to perform unrestricted brute-force attempts against administrative credentials...
CVE-2026-24437
Shenzhen Tenda W30E V2 firmware versions up to and including V16.01.0.195037 serve sensitive administrative content without appropriate cache-control directives. As a result, browsers may store credential-bearing responses locally, exposing them to subsequent unauthorized access...
CVE-2026-24439
Shenzhen Tenda W30E V2 firmware versions up to and including V16.01.0.195037 fail to include the X-Content-Type-Options: nosniff response header on web management interfaces. As a result, browsers that perform MIME sniffing may incorrectly interpret attacker-influenced responses as executable...
CVE-2026-24430
Shenzhen Tenda W30E V2 firmware versions up to and including V16.01.0.195037 disclose sensitive account credentials in cleartext within HTTP responses generated by the maintenance interface. Because the management interface is accessible over unencrypted HTTP by default, credentials may be expose...
CVE-2026-24429
Shenzhen Tenda W30E V2 firmware versions up to and including V16.01.0.195037 ship with a predefined default password for a built-in authentication account that is not required to be changed during initial configuration. An attacker can leverage these default credentials to gain authenticated acce...
EUVD-2026-4675
Shenzhen Tenda W30E V2 firmware versions up to and including V16.01.0.195037 implement an insecure Cross-Origin Resource Sharing CORS policy on authenticated administrative endpoints. The device sets Access-Control-Allow-Origin: in combination with Access-Control-Allow-Credentials: true, allowing...
CVE-2026-24432
Shenzhen Tenda W30E V2 firmware up to 16.01.0.19(5037) lacks CSRF protections on administrative endpoints, including password changes. An attacker could craft requests that, when triggered by an authenticated user’s browser, modify admin passwords and other settings. Root cause: missing CSRF prot...
CVE-2026-24431 Tenda W30E V2 Web UI Reveals Passwords in Cleartext
Shenzhen Tenda W30E V2 firmware versions up to and including V16.01.0.195037 display stored user account passwords in plaintext within the administrative web interface. Any user with access to the affected management pages can directly view credentials...
CVE-2026-24431 Tenda W30E V2 Web UI Reveals Passwords in Cleartext
Shenzhen Tenda W30E V2 firmware versions up to and including V16.01.0.195037 display stored user account passwords in plaintext within the administrative web interface. Any user with access to the affected management pages can directly view credentials...
CVE-2026-24437
Shenzhen Tenda W30E V2 firmware versions up to and including V16.01.0.195037 serve sensitive administrative content without appropriate cache-control directives. As a result, browsers may store credential-bearing responses locally, exposing them to subsequent unauthorized access...
CVE-2026-24436 Tenda W30E V2 Lacks Rate Limiting on Authentication
Shenzhen Tenda W30E V2 firmware versions up to and including V16.01.0.195037 do not enforce rate limiting or account lockout mechanisms on authentication endpoints. This allows attackers to perform unrestricted brute-force attempts against administrative credentials...
CVE-2026-24436 Tenda W30E V2 Lacks Rate Limiting on Authentication
Shenzhen Tenda W30E V2 firmware versions up to and including V16.01.0.195037 do not enforce rate limiting or account lockout mechanisms on authentication endpoints. This allows attackers to perform unrestricted brute-force attempts against administrative credentials...
CVE-2026-24428
The CVE-2026-24428 entry concerns Shenzhen Tenda W30E V2 firmware (up to and including V16.01.0.19(5037)) with an authorization flaw in the user management API. The concrete detail across sources is that a low-privileged authenticated user can alter the administrator password by sending a crafted...
PT-2026-4803
Shenzhen Tenda W30E V2 firmware versions up to and including V16.01.0.195037 fail to include the X-Content-Type-Options: nosniff response header on web management interfaces. As a result, browsers that perform MIME sniffing may incorrectly interpret attacker-influenced responses as executable...
EUVD-2025-27412
Malicious code in bioql PyPI...
EUVD-2025-27414
Malicious code in bioql PyPI...
EUVD-2025-27291
Malicious code in bioql PyPI...