9 matches found
CVE-2025-15218 Tenda AC10U POST Request Parameter AdvSetLanip fromadvsetlanip buffer overflow
A weakness has been identified in Tenda AC10U 15.03.06.48/15.03.06.49. Affected by this vulnerability is the function fromadvsetlanip of the file /goform/AdvSetLanip of the component POST Request Parameter Handler. Executing a manipulation of the argument lanMask can lead to buffer overflow. The...
CVE-2025-15215
A vulnerability was determined in Tenda AC10U 15.03.06.48/15.03.06.49. This affects the function formSetPPTPUserList of the file /goform/setPptpUserList of the component HTTP POST Request Handler. This manipulation of the argument list causes buffer overflow. It is possible to initiate the attack...
CVE-2025-15215 Tenda AC10U HTTP POST Request setPptpUserList formSetPPTPUserList buffer overflow
A vulnerability was determined in Tenda AC10U 15.03.06.48/15.03.06.49. This affects the function formSetPPTPUserList of the file /goform/setPptpUserList of the component HTTP POST Request Handler. This manipulation of the argument list causes buffer overflow. It is possible to initiate the attack...
Tenda AC10U 安全漏洞
Tenda AC10U is a wireless router from Tenda China. A security vulnerability exists in Tenda AC10U version 15.03.06.48 and 15.03.06.49, which originates from an incorrect operation of the parameter list in the file /goform/setPptpUserList, which may result in a buffer overflow...
PT-2025-53836
Name of the Vulnerable Software and Affected Versions Tenda AC10U versions 15.03.06.48 through 15.03.06.49 Description A buffer overflow issue exists in the formSetPPTPUserList function within the HTTP POST Request Handler component, specifically in the /goform/setPptpUserList file of the Tenda...
PT-2024-2344 · Tenda · Tenda Ac10
Name of the Vulnerable Software and Affected Versions: Tenda AC10U version 15.03.06.48 Description: A critical issue has been found in the function formSetCfm of the file goform/setcfm, where the manipulation of the argument funcpara1 leads to a stack-based buffer overflow. This can be exploited...
CVE-2024-2711
CVE-2024-2711 affects Tenda AC10U firmware 15.03.06.48. The vulnerability is in the addWifiMacFilter function located at /goform/addWifiMacFilter, where manipulating the deviceMac argument leads to a stack-based buffer overflow. Attacks may be launched remotely, and the exploit has been publicly ...
PT-2024-2350 · Tenda · Tenda Ac10
Name of the Vulnerable Software and Affected Versions: Tenda AC10U version 15.03.06.48 Description: A critical issue affects the addWifiMacFilter function of the file /goform/addWifiMacFilter, leading to a stack-based buffer overflow when the deviceMac argument is manipulated. This can be exploit...
PT-2024-2394 · Tenda · Tenda Ac10
Name of the Vulnerable Software and Affected Versions: Tenda AC10U versions 15.03.06.48 through 15.03.06.49 Description: A critical issue affects the function formSetSambaConf of the file /goform/setsambacfg. The manipulation of the argument usbName leads to os command injection. The attack may b...