23 matches found
CVE-2026-12031 vulnerabilities
Vulnerabilities for packages: chromium...
CVE-2026-12031 vulnerabilities
Vulnerabilities for packages: chromium...
Chromium: CVE-2026-12031 Inappropriate implementation Views
This CVE was assigned by Chrome. Microsoft Edge Chromium-based ingests Chromium, which addresses this vulnerability. Please see Google Chrome Releases for more information...
chromedriver-149.0.7827.114-1.1 on GA media (moderate)
chromedriver-149.0.7827.114-1.1 on GA media Announcement ID: openSUSE-SU-2026:11029-1 Rating: moderate Cross-References: CVE-2026-12007 CVE-2026-12008 CVE-2026-12009 CVE-2026-12010 CVE-2026-12011 CVE-2026-12012 CVE-2026-12013 CVE-2026-12014 CVE-2026-12015 CVE-2026-12016 CVE-2026-12017...
DEBIAN-CVE-2026-12031
Inappropriate implementation in Views in Google Chrome on Windows prior to 149.0.7827.115 allowed a remote attacker who had compromised the renderer process to potentially perform a sandbox escape via a crafted HTML page. Chromium security severity: High...
CVE-2026-12031
Inappropriate implementation in Views in Google Chrome on Windows prior to 149.0.7827.115 allowed a remote attacker who had compromised the renderer process to potentially perform a sandbox escape via a crafted HTML page. Chromium security severity: High...
CVE-2026-12031
Inappropriate implementation in Views in Google Chrome on Windows prior to 149.0.7827.115 allowed a remote attacker who had compromised the renderer process to potentially perform a sandbox escape via a crafted HTML page. Chromium security severity: High...
CVE-2026-12031
creationtimestamp| type| source ---|---|--- 2026-06-11 18:00:00+00:00| seen| https://www.hkcert.org/security-bulletin/google-chrome-multiple-vulnerabilities20260612 2026-06-12 04:00:40+00:00| seen| https://bsky.app/profile/thehackerwire.bsky.social/post/3mo2u4ktdqu2y 2026-06-12 05:14:42+00:00|...
RHSA-2026:12031 Red Hat Security Advisory: runc security update
Bulletin has no description...
CVE-2025-12031
creationtimestamp| type| source ---|---|--- 2025-10-21 17:42:11+00:00| seen| Telegram/HZRbfh6jT8ivaDwsimhW1YHLICjtgz2zMyIiRWvdppLQYjY...
CVE-2024-12031
CVE-2024-12031 refers to the Advanced Floating Content plugin for WordPress. The vulnerability is an SQL Injection caused by insufficient escaping of user input in the floating_content_duplicate_post path and by improper query construction (insufficient use of query preparation). The advisory not...
CVE-2024-12031 Advanced Floating Content <= 3.8.2 - Authenticated (Subscriber+) SQL Injection
The Advanced Floating Content plugin for WordPress is vulnerable to SQL Injection via the 'floatingcontentduplicatepost' function in all versions up to, and including, 3.8.2 due to insufficient escaping on the user supplied parameter and lack of sufficient preparation on the existing SQL query...
CVE-2024-12031 Advanced Floating Content <= 3.8.2 - Authenticated (Subscriber+) SQL Injection
The Advanced Floating Content plugin for WordPress is vulnerable to SQL Injection via the 'floatingcontentduplicatepost' function in all versions up to, and including, 3.8.2 due to insufficient escaping on the user supplied parameter and lack of sufficient preparation on the existing SQL query...
VulnCheck KEV: CVE-2018-12031
Local file inclusion in Eaton Intelligent Power Manager v1.6 allows an attacker to include a file via server/nodeupgradesrv.js directory traversal with the firmware parameter in a downloadFirmware action...
Rockwell (CVE-2020-12031) (deprecated)
Plugin deprecated because factorytalk is not detectable in this way This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 70300 C Tenable Network Security, Inc. @DEPRECATED@ Disabled on 2023/03/10. Deprecated because...
CVE-2020-12031 Rockwell Automation FactoryTalk View SE
In all versions of FactoryTalk View SE, after bypassing memory corruption mechanisms found in the operating system, a local, authenticated attacker may corrupt the associated memory space allowing for arbitrary code execution. Rockwell Automation recommends applying patch 1126290. Before installi...
CVE-2020-12031
CVE-2020-12031 affects all versions of Rockwell Automation’s FactoryTalk View SE. The vulnerability arises after bypassing the OS memory corruption mitigations, allowing a local, authenticated attacker to corrupt the target memory space and achieve arbitrary code execution. Multiple connected sou...
Eaton Intelligent Power Manager 1.6 - Directory Traversal
Exploit Title: Eaton Intelligent Power Manager 1.6 - Directory Traversal Date: 2018-09-29 Exploit Author: Emre ÖVÜNÇ Vendor Homepage: https://powerquality.eaton.com/ Software Link: https://powerquality.eaton.com/Support/Software-Drivers/default.asp?cx=-999 Version: v1.6 Tested on: Windows...