186 matches found
CVE-2021-0060
Insufficient compartmentalization in HECI subsystem for the IntelR SPS before versions SPSE504.01.04.516.0, SPSE504.04.04.033.0, SPSE504.04.03.281.0, SPSE503.01.03.116.0, SPSE305.01.04.309.0, SPS02.04.00.101.0, SPSSoC-A05.00.03.114.0, SPSSoC-X04.00.04.326.0, SPSSoC-X03.00.03.117.0,...
CVE-2021-0060
Insufficient compartmentalization in HECI subsystem for the IntelR SPS before versions SPSE504.01.04.516.0, SPSE504.04.04.033.0, SPSE504.04.03.281.0, SPSE503.01.03.116.0, SPSE305.01.04.309.0, SPS02.04.00.101.0, SPSSoC-A05.00.03.114.0, SPSSoC-X04.00.04.326.0, SPSSoC-X03.00.03.117.0,...
CVE-2021-0060
CVE-2021-0060 affects Intel Chipset Firmware’s Server Platform Services (SPS) HECI, where insufficient compartmentalization could let an authenticated user escalate privileges with physical access. Affected products include Intel SPS firmwares, before versions SPS_E5_04.01.04.516.0, SPS_E5_04.04....
2021.2 IPU – Intel® Chipset Firmware Advisory
Summary: Potential security vulnerabilities in some Intel® Chipset Firmware in Intel® Server Platform Services SPS, Intel® Active Management Technology AMT and the Intel Power Management Controller PMC may allow escalation of privilege or denial of service. Intel is releasing firmware updates to...
Mageia: Security Advisory (MGASA-2015-0060)
The remote host is missing an update for the SPDX-FileCopyrightText: 2022 Greenbone AG Some text descriptions might be excerpted from a referenced sources, and are Copyright C by the respective right holders. SPDX-License-Identifier: GPL-2.0-only ifdescription...
Mageia: Security Advisory (MGASA-2014-0205)
The remote host is missing an update for the SPDX-FileCopyrightText: 2022 Greenbone AG Some text descriptions might be excerpted from a referenced sources, and are Copyright C by the respective right holders. SPDX-License-Identifier: GPL-2.0-only ifdescription...
SUSE: Security Advisory (SUSE-SU-2022:0060-1)
The remote host is missing an update for the SPDX-FileCopyrightText: 2022 Greenbone AG Some text descriptions might be excerpted from a referenced sources, and are Copyright C by the respective right holders. SPDX-License-Identifier: GPL-2.0-only ifdescription...
SUSE: Security Advisory (SUSE-SU-2014:0461-1)
The remote host is missing an update for the SPDX-FileCopyrightText: 2021 Greenbone AG Some text descriptions might be excerpted from a referenced sources, and are Copyright C by the respective right holders. SPDX-License-Identifier: GPL-2.0-only ifdescription...
SUSE: Security Advisory (SUSE-SU-2021:0060-1)
The remote host is missing an update for the SPDX-FileCopyrightText: 2021 Greenbone AG Some text descriptions might be excerpted from a referenced sources, and are Copyright C by the respective right holders. SPDX-License-Identifier: GPL-2.0-only ifdescription...
SUSE: Security Advisory (SUSE-SU-2019:0060-1)
The remote host is missing an update for the SPDX-FileCopyrightText: 2021 Greenbone AG Some text descriptions might be excerpted from a referenced sources, and are Copyright C by the respective right holders. SPDX-License-Identifier: GPL-2.0-only ifdescription...
NewStart CGSL CORE 5.04 / MAIN 5.04 : rpm Multiple Vulnerabilities (NS-SA-2020-0039)
The remote NewStart CGSL host, running version CORE 5.04 / MAIN 5.04, has rpm packages installed that are affected by multiple vulnerabilities: - RPM 4.4.x through 4.9.x, probably before 4.9.1.2, allows remote attackers to cause a denial of service memory corruption and possibly execute arbitrary...
CVE-2020-0060
CVE-2020-0060 is documented as a SQL injection-based permission bypass in Android 10. The affected components are the SmsProvider.java and MmsSmsProvider.java query paths, enabling a local information disclosure with system-level privileges and no user interaction required for exploitation. The v...
Juniper JSA10970
The version of tested product installed on the remote host is prior to tested version. It is, therefore, affected by a vulnerability as referenced in the JSA10970 advisory. Note that Nessus has not tested for this issue but has instead relied only on the application's self- reported version numbe...
Junos OS: processing of specific transit IP packets in flowd, leading to Denial of Service (JSA10959)
The version of Junos OS installed on the remote host is prior to 15.1X49-D171 or 18.4R2. It is, therefore, affected by a vulnerability as referenced in the JSA10959 advisory. Note that Nessus has not tested for this issue but has instead relied only on the application's self-reported version...
CVE-2019-0060 Junos OS: SRX Series: flowd process crash due to processing of specific transit IP packets
The flowd process, responsible for forwarding traffic in SRX Series services gateways, may crash and restart when processing specific transit IP packets through an IPSec tunnel. Continued processing of these packets may result in an extended Denial of Service DoS condition. This issue only occurs...
CVE-2019-0060
The vulnerability CVE-2019-0060 affects Juniper Junos OS on SRX Series where the flowd process may crash and restart while processing specific transit IP packets through an IPSec tunnel, potentially causing a Denial of Service (DoS). Affected versions include Junos OS 15.1X49 prior to 15.1X49-D17...
Beckhoff C6240-0060 Industrial Computer Detection
Binary data 763441.prm...
Beckhoff C6930-0060 Industrial Computer Detection
Binary data 763477.prm...