20015 matches found
Mitsubishi Electric MELSEC iQ-F Series (Update B)
1. EXECUTIVE SUMMARY CVSS v3 8.6 ATTENTION: Exploitable remotely/low attack complexity Vendor: Mitsubishi Electric Equipment: MELSEC iQ-F Series Vulnerabilities: Improper Input Validation 2. UPDATE INFORMATION This updated advisory is a follow-up to the original advisory titled ICSA-22-139-01...
f-rates.com Cross Site Scripting vulnerability OBB-3198190
Following the coordinated and responsible vulnerability disclosure guidelines of the ISO 29147 standard, Open Bug Bounty has: a. verified the vulnerability and confirmed its existence; b. notified the website operator about its existence. Technical details of the vulnerability are currently hidde...
SUSE CVE-2006-4262
Multiple buffer overflows in cscope 15.5 and earlier allow user-assisted attackers to cause a denial of service crash and possibly execute arbitrary code via multiple vectors including 1 a long pathname that is not properly handled during file list parsing, 2 long pathnames that result from path...
SUSE CVE-2010-3906
Cross-site scripting XSS vulnerability in Gitweb 1.7.3.3 and earlier allows remote attackers to inject arbitrary web script or HTML via the 1 f and 2 fp parameters...
SUSE CVE-2014-10402
An issue was discovered in the DBI module through 1.643 for Perl. DBD::File drivers can open files from folders other than those specifically passed via the fdir attribute in the data source name DSN. NOTE: this issue exists because of an incomplete fix for CVE-2014-10401...
SUSE CVE-2018-20961
In the Linux kernel before 4.16.4, a double free vulnerability in the fmidisetalt function of drivers/usb/gadget/function/fmidi.c in the fmidi driver may allow attackers to cause a denial of service or possibly have unspecified other impact...
SUSE CVE-2019-18786
In the Linux kernel through 5.3.8, f-fmt.sdr.reserved is uninitialized in rcardrifgfmtsdrcap in drivers/media/platform/rcardrif.c, which could cause a memory disclosure problem...
CVE-2022-33323
CVE-2022-33323 affects Mitsubishi Electric MELFA MELFA SD/SQ and F-Series robot controllers. Root cause: active debug code enables an authentication bypass allowing a remote, unauthenticated telnet login to gain unauthorized access. Affected firmware versions include S7x/R7x and prior; fixes are ...
CVE-2022-33323 Authentication Bypass Vulnerability in Robot Controller of MELFA SD/SQ series and F-series
Active Debug Code vulnerability in robot controller of Mitsubishi Electric Corporation industrial robot MELFA SD/SQ Series and MELFA F-Series allows a remote unauthenticated attacker to gain unauthorized access by authentication bypass through an unauthorized telnet login. As for the affected mod...
PT-2023-1355 · Mitsubishi · Melfa Sd/Sq Series +1
Name of the Vulnerable Software and Affected Versions: Mitsubishi Electric Corporation industrial robot MELFA SD/SQ Series and MELFA F-Series affected versions not specified Description: The issue concerns a remote unauthenticated attacker gaining unauthorized access through an unauthorized telne...
PHOENIX CONTACT PLCNext AXC F 2152 Channel Accessible By Non-Endpoint (CVE-2019-10997)
An issue was discovered on Phoenix Contact AXC F 2152 No.2404267 before 2019.0 LTS and AXC F 2152 STARTERKIT No.1046568 before 2019.0 LTS devices. Protocol Fuzzing on PC WORX Engineer by a man in the middle attacker stops the PLC service. The device must be rebooted, or the PLC service must be...
PHOENIX CONTACT PLCNext AXC F 2152 Improper Access Control (CVE-2019-10998)
An issue was discovered on Phoenix Contact AXC F 2152 No.2404267 before 2019.0 LTS and AXC F 2152 STARTERKIT No.1046568 before 2019.0 LTS devices. Unlimited physical access to the PLC may lead to a manipulation of SD cards data. SD card manipulation may lead to an authentication bypass opportunit...
CVE-2022-40267
Predictable Seed in Pseudo-Random Number Generator PRNG vulnerability in Mitsubishi Electric Corporation MELSEC iQ-F Series FX5U-xMy/z x=32,64,80, y=T,R, z=ES,DS,ESS,DSS with serial number 17X or later, and versions 1.280 and prior, Mitsubishi Electric Corporation MELSEC iQ-F Series FX5U-xMy/z...
CVE-2022-40267
The CVE-2022-40267 issue is an authentication bypass in Mitsubishi Electric MELSEC iQ-F/iQ-R Series web servers caused by a Predictable Seed in the PRNG used for session identifiers. TALOS details show an LCG-based generator that seeds future values with previously produced random numbers, enabli...
CVE-2022-40267 Authentication Bypass Vulnerability in Web Server Function on MELSEC Series
Predictable Seed in Pseudo-Random Number Generator PRNG vulnerability in Mitsubishi Electric Corporation MELSEC iQ-F Series FX5U-xMy/z x=32,64,80, y=T,R, z=ES,DS,ESS,DSS with serial number 17X or later, and versions 1.280 and prior, Mitsubishi Electric Corporation MELSEC iQ-F Series FX5U-xMy/z...
PT-2023-13779 · Mitsubishi · Melsec Iq-F Series Fx5Uc-32Mr/Ds-Ts +4
Name of the Vulnerable Software and Affected Versions: Mitsubishi Electric Corporation MELSEC iQ-F Series FX5U-xMy/z versions 1.280 and prior Mitsubishi Electric Corporation MELSEC iQ-F Series FX5U-xMy/z versions 1.074 and prior Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UC-xMy/z...
PT-2023-34148 · Linux · Linux Kernel
Name of the Vulnerable Software and Affected Versions: Linux Kernel versions prior to v5.15.86 Description: A refcount leak was discovered in the f hid gadget of the Linux Kernel. The issue was introduced in version v3.19 and is fixed in version v5.15.86. The actual impact and attack plausibility...
Mitsubishi Electric MELSEC iQ-F, iQ-R Series
1. EXECUTIVE SUMMARY CVSS v3 5.9 ATTENTION: Exploitable remotely Vendor: Mitsubishi Electric Equipment: MELSEC iQ-F and iQ-R Series products Vulnerability: Predictable Seed in Pseudo-Random Number Generator PRNG 2. UPDATE OR REPOSTED INFORMATION This updated advisory is a follow-up to the...
CVE-2022-46360
Out-of-bounds read vulnerability in V-SFT v6.1.7.0 and earlier and TELLUS v4.0.12.0 and earlier allows a local attacker to obtain the information and/or execute arbitrary code by having a user to open a specially crafted image file...