1980 matches found
CVE-2019-25721: Uncontrolled Resource Consumption
Dräger Infinity M300 patient worn monitors with software version VG2.3.1 and earlier contain a network-based denial of service vulnerability that allows network-adjacent attackers to repeatedly trigger device reboots by sending malicious requests over the Infinity Network. Attackers can exploit...
CVE-2024-14036: Uncontrolled Resource Consumption
Dräger Core 1.0.5 and Dräger M540 Converter Service 1.0.9 contain a denial of service vulnerability that allows network-adjacent attackers to trigger high CPU load by sending specially crafted, unencrypted SDC messages during the discovery process. Attackers with access to the hospital network ca...
CVE-2026-49144: Improper Limitation of a Pathname to a Restricted Directory
BrowserStack Runner through 0.9.5 contains a path traversal vulnerability in the default HTTP handler in lib/server.js that allows unauthenticated network-adjacent attackers to read arbitrary files. Attackers can exploit the unauthenticated HTTP server bound on all interfaces to traverse outside...
Missing Authentication for Critical Function
Overview 9router is a 9Router CLI - Start and manage 9Router server Affected versions of this package are vulnerable to Missing Authentication for Critical Function due to exposing two unauthenticated API endpoints that, when chained together, allow any network-adjacent attacker to execute...
PT-2026-40779
A denial of service DoS vulnerability in Palo Alto Networks Prisma SD-WAN ION devices enables an unauthenticated attacker in a network adjacent to a Prisma SD-WAN ION device to cause a system disruption by sending a specially crafted IPv6 packet...
CVE-2026-4156 ChargePoint Home Flex OCPP getpreq Stack-based Buffer Overflow Remote Code Execution Vulnerability
ChargePoint Home Flex OCPP getpreq Stack-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of ChargePoint Home Flex EV chargers. Authentication is not required to exploit this...
CVE-2026-4156: Stack-based Buffer Overflow
ChargePoint Home Flex OCPP getpreq Stack-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of ChargePoint Home Flex EV chargers. Authentication is not required to exploit this...
CVE-2026-4157: Improper Neutralization of Special Elements used in an OS Command
ChargePoint Home Flex revssh Service Command Injection Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of ChargePoint Home Flex devices. Authentication is not required to exploit this vulnerability. The...
linux-pam: Plaintext password recovery via timing discrepancy in pam_userdb module
A flaw was found in Linux-PAM's pamuserdb module. This vulnerability, categorized as an Observable Timing Discrepancy CWE-208, allows a local or network-adjacent attacker to recover plaintext passwords. By repeatedly attempting authentication and measuring response-timing differences during...
PT-2026-31783
Name of the Vulnerable Software and Affected Versions PraisonAI versions prior to 4.5.128 Description PraisonAI is a multi-agent teams system. The /api/v1/runs endpoint accepts an arbitrary webhook url in the request body without URL validation. Upon job completion success or failure, the server...
CVE-2026-2491
Socomec DIRIS A-40 HTTP API Authentication Bypass Vulnerability. This vulnerability allows network-adjacent attackers to bypass authentication on affected installations of Socomec DIRIS A-40 power monitoring devices. Authentication is not required to exploit this vulnerability. The specific flaw...
CVE-2026-3557
Philips Hue Bridge happairverifyhandler Sub-TLV Parsing Heap-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Philips Hue Bridge. Although authentication is required to exploit th...
EUVD-2026-12160
Philips Hue Bridge HomeKit Accessory Protocol Static Nonce Authentication Bypass Vulnerability. This vulnerability allows network-adjacent attackers to bypass authentication on affected installations of Philips Hue Bridge. Authentication is not required to exploit this vulnerability. The specific...
EUVD-2026-12162
Philips Hue Bridge hkhap characteristics Heap-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Philips Hue Bridge. Although authentication is required to exploit this vulnerabilit...
CVE-2026-3562
Philips Hue Bridge hkhap Ed25519 Signature Verification Authentication Bypass Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Philips Hue Bridge. Authentication is not required to exploit this vulnerability. The specific...
CVE-2026-3559: Reusing a Nonce, Key Pair in Encryption
Philips Hue Bridge HomeKit Accessory Protocol Static Nonce Authentication Bypass Vulnerability. This vulnerability allows network-adjacent attackers to bypass authentication on affected installations of Philips Hue Bridge. Authentication is not required to exploit this vulnerability. The specific...
CVE-2026-3558: Missing Authentication for Critical Function
Philips Hue Bridge HomeKit Accessory Protocol Transient Pairing Mode Authentication Bypass Vulnerability. This vulnerability allows network-adjacent attackers to bypass authentication on affected installations of Philips Hue Bridge. Authentication is not required to exploit this vulnerability. Th...
CVE-2026-3556: Heap-based Buffer Overflow
Philips Hue Bridge HomeKit Pair-Setup Heap-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Philips Hue Bridge. Authentication is not required to exploit this vulnerability. The...
CVE-2026-3555: Heap-based Buffer Overflow
Philips Hue Bridge Zigbee Stack Custom Command Handler Heap-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Philips Hue Bridge. User interaction is required to exploit this...
CVE-2026-3560: Heap-based Buffer Overflow
Philips Hue Bridge HomeKit hkhappairstorageput Heap-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Philips Hue Bridge. Authentication is not required to exploit this...