62 matches found
CVE-2019-5013
An exploitable privilege escalation vulnerability exists in the Wacom, driver version 6.3.32-3, update helper service in the start/stopLaunchDProcess command. The command takes a user-supplied string argument and executes launchctl under root context. A user with local access can use this...
Siemens SIMATIC S7-300 PLC Privilege Bypass Vulnerability
The Siemens SIMATIC S7-300 CPU is a modular general-purpose controller from Siemens for the manufacturing industry. The Siemens SIMATIC S7-300 PLC module is vulnerable to an unauthorized, execute CPU attack via privilege bypass. An attacker can construct special application layer data messages th...
Privilege Bypass Vulnerability in Schneider Electric P3420 PLC Module
Schneider Electric Modicon M340 PLC is a programmable controller product of Schneider Electric France. A privilege bypass vulnerability exists in the Schneider Electric P3420 PLC module. An attacker can cause the PLC to start and stop by constructing PLC start-stop data messages using private...
PT-2019-16789 · Crestron · Crestron Am-100 +1
Name of the Vulnerable Software and Affected Versions: Crestron AM-100 version 1.6.0.2 Crestron AM-101 version 2.7.0.2 Description: The issue allows a remote, unauthenticated attacker to act as a moderator for a slide show by sending crafted HTTP POST requests to the "conference.cgi" endpoint. Th...
PT-2019-19883
Name of the Vulnerable Software and Affected Versions Screen Stream versions through 3.0.15 Description The issue allows remote attackers to cause a denial of service via many simultaneous "/start-stop" requests. Recommendations For versions through 3.0.15, update to a version that contains a fix...
CVE-2019-9833: Undefined Security Weakness
The Screen Stream application through 3.0.15 for Android allows remote attackers to cause a denial of service via many simultaneous /start-stop requests...
Remote Control Vulnerability in MAC1100 PLCs
The MAC1100 PLC Programmable Logic Controller PLC is a product in the Dalian Computer Control DCCE Programmable Logic Controller PLC series. A remote control vulnerability exists in the MAC1100 PLC. An attacker can use the vulnerability to remotely and directly control the start and stop of the...
PT-2018-17168
Name of the Vulnerable Software and Affected Versions: Qualcomm Android for MSM versions prior to security patch level 2018-04-05 Firefox OS for MSM versions prior to security patch level 2018-04-05 QRD Android versions prior to security patch level 2018-04-05 Description: The issue arises from t...
CVE-2017-18240
The Gentoo app-admin/collectd package before 5.7.2-r1 sets the ownership of PID file directory to the collectd account, which might allow local users to kill arbitrary processes by leveraging access to this account for PID file modification before a root script sends a SIGKILL when the service is...
ICMPExfil - Exfiltrate data with ICMP
ICMP Exfil allows you to transmit data via valid ICMP packets. You use the client script to pass in data you wish to exfiltrate, then on the device you're transmitting to you run the server. Anyone watching-- human or security system-- will just see valid ICMP packets, there's nothing malicious...
Siemens 300/400 Series PLC Remote Control Vulnerability
Programmable controller PLC is developed on the basis of relay control and computer control, and gradually developed into a new type of industrial automatic control device based on microprocessor and integrating modern technologies such as computer technology, automatic control technology and...
Siemens Simatic S7 1200 CPU Command Module (MSF) Exploit
Exploit for hardware platform in category remote exploits Exploit Title: Simatic S7 1200 CPU command module Date: 15-12-2015 Exploit Author: Nguyen Manh Hung Vendor Homepage: http://www.siemens.com/ Tested on: Siemens Simatic S7-1214C CVE : None require 'msf/core' class Metasploit3 'Simatic S7-12...
Siemens Simatic S7 1200 - CPU Command Module (Metasploit)
Siemens Simatic S7 1200 - CPU Command Module Metasploit Exploit Title: Simatic S7 1200 CPU command module Date: 15-12-2015 Exploit Author: Nguyen Manh Hung Vendor Homepage: http://www.siemens.com/ Tested on: Siemens Simatic S7-1214C CVE : None require 'msf/core' class Metasploit3 'Simatic S7-1200...
CVE-2015-5011
IBM WebSphere Message Broker 8 before 8.0.0.6 and Integration Bus 9 before 9.0.0.4 do not check authorization for MQSISTARTMSGFLOW and MQSISTOPMSGFLOW commands, which allows local users to bypass intended access restrictions, and start or stop a service, by issuing a command...
Multiple Cross-Site Request Forgery Vulnerabilities in Landesk Management Suite
LANDESK Management Suite is a set of IT systems management solutions from the U.S. company LANDESK. A cross-site request forgery vulnerability exists in LANDESK Management Suite 9, which allows remote attackers to construct malicious URIs, trick users into parsing them, and perform malicious...
Siemens Simatic S7-300/400 CPU START/STOP Module
No description provided by source...
Siemens Simatic S7-1200 CPU START/STOP Module
No description provided by source...
Siemens Simatic S7-1200 - CPU STARTSTOP Module (Metasploit)
Siemens Simatic S7-1200 - CPU STARTSTOP Module Metasploit Exploit Title: Siemens Simatic S7 1200 CPU command module Date: 7-13-2012 Exploit Author: Dillon Beresford Vendor Homepage: http://www.siemens.com/ Tested on: Siemens Simatic S7-1200 PLC CVE : None require 'msf/core' class Metasploit3...
CVE-2011-1402
Mahara before 1.3.6 allows remote authenticated users to bypass intended access restrictions, and suspend a user account, edit a view, visit a view, edit a plan artefact, read a plans block, read a plan artefact, edit a blog, read a blog block, read a blog artefact, or access a block, via a reque...
CVE-2011-1402
Mahara before 1.3.6 allows remote authenticated users to bypass intended access restrictions, and suspend a user account, edit a view, visit a view, edit a plan artefact, read a plans block, read a plan artefact, edit a blog, read a blog block, read a blog artefact, or access a block, via a reque...