CVE-2017-16751
CVE-2017-16751 affects Delta Electronics’ Delta Industrial Automation Screen Editor (version 2.00.23.00 or prior). The vulnerability is a stack-based buffer overflow triggered while parsing .dpb project files , which could allow an attacker to execute arbitrary code. Multiple connected sources co...
CVE-2017-16747
An Out-of-bounds Write issue was discovered in Delta Electronics Delta Industrial Automation Screen Editor, Version 2.00.23.00 or prior. Specially crafted .dpb files may cause the system to write outside the intended buffer area...
CVE-2017-16747
CVE-2017-16747 affects Delta Electronics’ Delta Industrial Automation Screen Editor (Version 2.00.23.00 and earlier). The vulnerability is an out-of-bounds write while processing specially crafted .dpb project files, potentially allowing remote code execution or program crashes. Public exploitati...
CVE-2017-16749
A Use-after-Free issue was discovered in Delta Electronics Delta Industrial Automation Screen Editor, Version 2.00.23.00 or prior. Specially crafted .dpb files could exploit a use-after-free vulnerability...
CVE-2017-16745
Delta Electronics’ Delta Industrial Automation Screen Editor (Version 2.00.23.00 and earlier) contains a type confusion vulnerability in the DPB project file parsing, specifically involving the CThemeWnd handling. Exploitation with specially crafted DPB files could allow remote code execution. Pu...
CVE-2017-16749
Delta Electronics Delta Industrial Automation Screen Editor (v2.00.23.00 or earlier) contains a Use-after-Free in the DPB project file parser (CDocument path). Exploitation requires user interaction and is locally scoped (AV:L, UI:R). Successful exploitation could allow arbitrary code execution. ...
CVE-2018-8721
Zoho ManageEngine EventLog Analyzer version 11.0 build 11000 has Stored XSS related to the index2.do?url=editAlertForm&tab=alert&alert=profile URI and the Edit Alert Profile screen...
PT-2018-6324
Name of the Vulnerable Software and Affected Versions: Delta Electronics Delta Industrial Automation Screen Editor versions 2.00.23.00 and prior Description: An Out-of-bounds Write issue was discovered, where specially crafted .dpb files may cause the system to write outside the intended buffer...
PT-2018-6327
Name of the Vulnerable Software and Affected Versions: Delta Electronics Delta Industrial Automation Screen Editor version 2.00.23.00 or prior Description: A Stack-based Buffer Overflow issue was discovered, caused by processing specially crafted .dpb files, which may allow an attacker to remotel...
CVE-2017-16747: Out-of-bounds Write
An Out-of-bounds Write issue was discovered in Delta Electronics Delta Industrial Automation Screen Editor, Version 2.00.23.00 or prior. Specially crafted .dpb files may cause the system to write outside the intended buffer area...
CVE-2017-16745: Access of Resource Using Incompatible Type
A Type Confusion issue was discovered in Delta Electronics Delta Industrial Automation Screen Editor, Version 2.00.23.00 or prior. An access of resource using incompatible type 'type confusion' vulnerability may allow an attacker to execute remote code when processing specially crafted .dpb files...
CVE-2017-16749: Use After Free
A Use-after-Free issue was discovered in Delta Electronics Delta Industrial Automation Screen Editor, Version 2.00.23.00 or prior. Specially crafted .dpb files could exploit a use-after-free vulnerability...
PT-2018-6326
Name of the Vulnerable Software and Affected Versions: Delta Electronics Delta Industrial Automation Screen Editor versions 2.00.23.00 and prior Description: A Use-after-Free issue was discovered, which can be exploited using specially crafted .dpb files. Recommendations: For versions 2.00.23.00...
PT-2018-6323
Name of the Vulnerable Software and Affected Versions: Delta Electronics Delta Industrial Automation Screen Editor versions 2.00.23.00 and prior Description: A Type Confusion issue may allow an attacker to execute remote code when processing specially crafted .dpb files. This occurs due to an...
CVE-2017-16751: Stack-based Buffer Overflow
A Stack-based Buffer Overflow issue was discovered in Delta Electronics Delta Industrial Automation Screen Editor, Version 2.00.23.00 or prior. Stack-based buffer overflow vulnerabilities caused by processing specially crafted .dpb files may allow an attacker to remotely execute arbitrary code...
Windows 2016 Target Devices are not booting after upgrade to Provisioning Services 7.15.1 or 7.16
After upgrading Windows2016 Target devices from Provisioning Services 7.15 to 7.15.1 or 7.16, the device could be stuck at Windows logo or black screen at boot time...
CVE-2018-7675
In NetIQ Sentinel before 8.1.x, a Sentinel user is logged into the Sentinel Web Interface. After performing some tasks within Sentinel the user does not log out but does go idle for a period of time. This in turn causes the interface to timeout so that it requires the user to re-authenticate. If...
Receiver for Windows 4.9LTSR/4.10 - Citrix HDX Engine Crash When Connecting to Linux VDA
This article is intended for Citrix administrators and technical teams only. Non-admin users must contact their company’s Help Desk/IT support team and can refer to CTX297149 for more information. When connecting from a client machine that has Receiver 4.9 LTSR or Receiver 4.10 upgraded from...
Someone hacked this advertising screen to mine Bitcoin
By Waqas The sudden surge in the price of Bitcoin encouraged the This is a post from HackRead.com Read the original post: Someone hacked this advertising screen to mine Bitcoin...
[20180504] - Core - Installer leaks plain text password to local user
The web install application would autofill password fields after either a form validation error or navigating to a previous install step, and displays the plain text password for the administrator account at the confirmation screen...