Lucene search
+L

4193 matches found

Malwarebytes
Malwarebytes
•added 2019/04/01 8:24 a.m.•91 views

A week in security (March 25 – 31)

Last week, we looked at plugin vulnerabilities, location tracking app problems, and talked about plain text password woes. We also looked at federal data privacy regulation and took a deep dive into BatMobi Adware. Other cybersecurity news Poisoned software update headache for ASUS Source: The...

0.3AI score
SaveExploits0
Prion
Prion
•added 2019/03/26 6:29 p.m.•32 views

Command injection

Data Leakage Attacks vulnerability in the web portal component when in an MDR pair in McAfee Network Security Management NSM 9.1 9.1.7.75 Update 4 and 9.2 9.2.7.31 Update2 allows administrators to view configuration information in plain text format via the GUI or GUI terminal commands...

1.9CVSS4.4AI score0.00211EPSS
SaveExploits0References2Affected Software1
CVE
CVE
•added 2019/03/26 5:23 p.m.•69 views

CVE-2019-3606

CVE-2019-3606 affects McAfee Network Security Manager (NSM) in the web portal component when running NSM 9.x with versions prior to 9.1.7.75 Update 4 or 9.2.7.31 Update2. The issue enables data leakage by allowing administrators to view configuration information in plain text via the GUI or GUI t...

7.7CVSS4.5AI score0.00211EPSS
SaveExploits0References2Affected Software1
Positive Technologies
Positive Technologies
•added 2019/03/26 12:00 a.m.•5 views

PT-2019-16635

Name of the Vulnerable Software and Affected Versions McAfee Network Security Management NSM versions 9.1 through 9.1.7.75 Update 4 McAfee Network Security Management NSM versions 9.2 through 9.2.7.31 Update2 Description The issue allows administrators to view configuration information in plain...

7.7CVSS0.00211EPSS
SaveExploits0References4
Prion
Prion
•added 2019/03/25 7:29 p.m.•24 views

Design/Logic Flaw

Wireless keys are stored in plain text on version 5 of the Hospira LifeCare PCA Infusion System. According to Hospira, version 3 of the LifeCare PCA Infusion System is not indicated for wireless use, is not shipped with wireless capabilities, and should not be modified to be used in a wireless...

5CVSS6.8AI score0.00771EPSS
SaveExploits0References1Affected Software1
NVD
NVD
•added 2019/03/25 7:29 p.m.•26 views

CVE-2015-1012

Wireless keys are stored in plain text on version 5 of the Hospira LifeCare PCA Infusion System. According to Hospira, version 3 of the LifeCare PCA Infusion System is not indicated for wireless use, is not shipped with wireless capabilities, and should not be modified to be used in a wireless...

7.5CVSS7.5AI score0.00771EPSS
SaveExploits0References1
Cvelist
Cvelist
•added 2019/03/25 6:20 p.m.•34 views

CVE-2015-1012

Wireless keys are stored in plain text on version 5 of the Hospira LifeCare PCA Infusion System. According to Hospira, version 3 of the LifeCare PCA Infusion System is not indicated for wireless use, is not shipped with wireless capabilities, and should not be modified to be used in a wireless...

7.5AI score0.00771EPSS
SaveExploits0References1
CVE
CVE
•added 2019/03/25 6:20 p.m.•63 views

CVE-2015-1012

The CVE-2015-1012 entry concerns the Hospira LifeCare PCA Infusion System. Vulnerabilities include cleartext storage of wireless network keys and hardcoded credentials, with multiple related issues (e.g., improper authorization, insufficient verification of data authenticity) that could enable un...

7.5CVSS7.5AI score0.00771EPSS
SaveExploits0References1Affected Software1
Prion
Prion
•added 2019/03/25 4:29 p.m.•29 views

Authorization

Wireless keys are stored in plain text on Hospira Plum A+ Infusion System version 13.4 and prior, Plum A+3 Infusion System version 13.6 and prior, and Symbiq Infusion System, version 3.13 and prior. Hospira recommends that customers close Port 20/FTP and Port 23/TELNET on the affected devices...

5CVSS6.6AI score0.01008EPSS
SaveExploits0References1Affected Software3
NVD
NVD
•added 2019/03/25 4:29 p.m.•36 views

CVE-2015-3952

Wireless keys are stored in plain text on Hospira Plum A+ Infusion System version 13.4 and prior, Plum A+3 Infusion System version 13.6 and prior, and Symbiq Infusion System, version 3.13 and prior. Hospira recommends that customers close Port 20/FTP and Port 23/TELNET on the affected devices...

7.5CVSS8AI score0.01008EPSS
SaveExploits0References1
Cvelist
Cvelist
•added 2019/03/25 3:42 p.m.•38 views

CVE-2015-3952

Wireless keys are stored in plain text on Hospira Plum A+ Infusion System version 13.4 and prior, Plum A+3 Infusion System version 13.6 and prior, and Symbiq Infusion System, version 3.13 and prior. Hospira recommends that customers close Port 20/FTP and Port 23/TELNET on the affected devices...

7.4AI score0.01008EPSS
SaveExploits0References1
CVE
CVE
•added 2019/03/25 3:42 p.m.•69 views

CVE-2015-3952

Summary: CVE-2015-3952 concerns information disclosure from Hospira infusion systems where wireless keys are stored in plain text. Affected products: Plum A+ Infusion System v13.4 and earlier, Plum A+3 Infusion System v13.6 and earlier, and Symbiq Infusion System v3.13 and earlier. Root cause: cl...

7.5CVSS7.3AI score0.01008EPSS
SaveExploits0References1Affected Software1
Positive Technologies
Positive Technologies
•added 2019/03/25 12:00 a.m.•5 views

PT-2019-7164

Name of the Vulnerable Software and Affected Versions Hospira LifeCare PCA Infusion System version 5 Description The issue concerns the storage of wireless keys in plain text. According to the information provided, version 3 of the system is not intended for wireless use and should not be modifie...

7.5CVSS0.00771EPSS
SaveExploits0References2
Jenkins Security Advisories
Jenkins Security Advisories
•added 2019/03/25 12:00 a.m.•36 views

Codebeamer Test Results Trend Updater Plugin stored password in plain text

Codebeamer Test Results Trend Updater Plugin stored username and password in its configuration unencrypted in jobs' config.xml files on the Jenkins controller. This password could be viewed by users with Extended Read permission, or access to the Jenkins controller file system. The plugin now...

4.3CVSS5.4AI score
SaveExploits0Affected Software1
Positive Technologies
Positive Technologies
•added 2019/03/25 12:00 a.m.•7 views

PT-2019-7181

Name of the Vulnerable Software and Affected Versions Hospira Plum A+ Infusion System versions 13.4 and prior Hospira Plum A+3 Infusion System versions 13.6 and prior Hospira Symbiq Infusion System versions 3.13 and prior Description The issue concerns the storage of wireless keys in plain text. ...

7.5CVSS0.01008EPSS
SaveExploits0References2
HackRead
HackRead
•added 2019/03/22 1:35 a.m.•123 views

Facebook stored 600m user passwords in plain text exposed to 20k employees

By Uzair Amir The company says it discovered the issue in January and there is no need to change passwords. The social media giant Facebook has revealed that its internal data storage systems saved user passwords in plain text that could be accessed by employees. The social media said an ongoing...

1.8AI score
SaveExploits0
ThreatPost
ThreatPost
•added 2019/03/21 5:14 p.m.•99 views

Facebook Stored Passwords in Plain Text For Years

Hundreds of millions of Facebook user passwords have been stored in plain text for years, the social media giant acknowledged on Thursday. KrebsOnSecurity, which first reported the news, said that specifically between 200 and 600 million passwords were stored in plain text as early as 2012, and...

7AI score
SaveExploits0References6
Krebs on Security
Krebs on Security
•added 2019/03/21 3:17 p.m.•36 views

Facebook Stored Hundreds of Millions of User Passwords in Plain Text for Years

Hundreds of millions of Facebook users had their account passwords stored in plain text and searchable by thousands of Facebook employees -- in some cases going back to 2012, KrebsOnSecurity has learned. Facebook says an ongoing investigation has so far found no indication that employees have...

7.2AI score
SaveExploits0
OSV
OSV
•added 2019/03/13 9:29 p.m.•13 views

CVE-2019-3716

RSA Archer versions, prior to 6.5 SP2, contain an information exposure vulnerability. The database connection password may get logged in plain text in the RSA Archer log files. An authenticated malicious local user with access to the log files may obtain the exposed password to use it in further...

7.8CVSS7.1AI score0.00377EPSS
SaveExploits0References2
OSV
OSV
•added 2019/03/13 9:29 p.m.•18 views

CVE-2019-3715

RSA Archer versions, prior to 6.5 SP1, contain an information exposure vulnerability. Users' session information is logged in plain text in the RSA Archer log files. An authenticated malicious local user with access to the log files may obtain the exposed information to use it in further attacks...

5.5CVSS6.7AI score0.00349EPSS
SaveExploits0References2