Lucene search
+L

3259 matches found

Prion
Prion
•added 2016/10/05 10:59 a.m.•25 views

Authentication flaw

Johnson & Johnson Animas OneTouch Ping devices mishandle acknowledgements, which makes it easier for remote attackers to bypass authentication via a custom communication protocol...

9.3CVSS7.5AI score0.04519EPSS
SaveExploits0References4
Prion
Prion
•added 2016/10/05 10:59 a.m.•37 views

Information disclosure

Johnson & Johnson Animas OneTouch Ping devices do not use encryption for certain data, which might allow remote attackers to obtain sensitive information by sniffing the network...

5CVSS6.8AI score0.02221EPSS
SaveExploits0References5
Cvelist
Cvelist
•added 2016/10/05 10:00 a.m.•37 views

CVE-2016-5686

Johnson & Johnson Animas OneTouch Ping devices mishandle acknowledgements, which makes it easier for remote attackers to bypass authentication via a custom communication protocol...

9.7AI score0.04519EPSS
SaveExploits0References4
CVE
CVE
•added 2016/10/05 10:00 a.m.•82 views

CVE-2016-5084

CVE-2016-5084 affects the Animas OneTouch Ping insulin pump system. Public details from ICS-CERT/URS indicate radio-frequency communications between the meter remote and pump transmit data in cleartext (CWE-319) and expose patient treatment/device data to unauthenticated remote listeners; related...

7.5CVSS7.8AI score0.02221EPSS
SaveExploits0References5Affected Software1
CVE
CVE
•added 2016/10/05 10:00 a.m.•63 views

CVE-2016-5085

CVE-2016-5085 affects the Animas OneTouch Ping insulin pump system. The vulnerability stems from use of a static or non-changing CRC32-derived value as an encryption key during the pairing/authentication handshake, enabling an unauthenticated remote attacker to sniff RF communications between the...

7.8CVSS8.1AI score0.03864EPSS
SaveExploits0References5Affected Software1
CVE
CVE
•added 2016/10/05 10:00 a.m.•67 views

CVE-2016-5086

The connected documents confirm CVE-2016-5086 affects the Animas OneTouch Ping insulin pump system, where a lack of protections in the custom radio-frequency protocol enables authentication bypass via capture‑replay. In practice, an unauthenticated remote attacker could replay captured commands t...

9.8CVSS9.6AI score0.04519EPSS
SaveExploits0References5Affected Software1
CVE
CVE
•added 2016/10/05 10:00 a.m.•59 views

CVE-2016-5686

The CVE-2016-5686 issue affects the Johnson & Johnson Animas OneTouch Ping insulin pump. It stems from a custom communication protocol that mishandles acknowledgements, allowing an unauthenticated remote attacker to spoof acknowledgement packets and bypass authentication. This could enable comman...

9.8CVSS9.5AI score0.04519EPSS
SaveExploits0References4Affected Software1
Cvelist
Cvelist
•added 2016/10/05 10:00 a.m.•45 views

CVE-2016-5086

Johnson & Johnson Animas OneTouch Ping devices allow remote attackers to bypass authentication via replay attacks...

9.8AI score0.04519EPSS
SaveExploits0References5
Cvelist
Cvelist
•added 2016/10/05 10:00 a.m.•45 views

CVE-2016-5085

Johnson & Johnson Animas OneTouch Ping devices do not properly generate random numbers, which makes it easier for remote attackers to spoof meters by sniffing the network and then engaging in an authentication handshake...

7.8AI score0.03864EPSS
SaveExploits0References5
Cvelist
Cvelist
•added 2016/10/05 10:00 a.m.•46 views

CVE-2016-5084

Johnson & Johnson Animas OneTouch Ping devices do not use encryption for certain data, which might allow remote attackers to obtain sensitive information by sniffing the network...

7.5AI score0.02221EPSS
SaveExploits0References5
Positive Technologies
Positive Technologies
•added 2016/10/05 12:00 a.m.•5 views

PT-2016-6236

Name of the Vulnerable Software and Affected Versions Johnson & Johnson Animas OneTouch Ping devices affected versions not specified Description The issue concerns the generation of random numbers in the devices, making it easier for remote attackers to spoof meters. This can be achieved by...

7.8CVSS0.03864EPSS
SaveExploits0References6
Positive Technologies
Positive Technologies
•added 2016/10/05 12:00 a.m.•7 views

PT-2016-6235

Name of the Vulnerable Software and Affected Versions Johnson & Johnson Animas OneTouch Ping devices affected versions not specified Description The issue concerns the lack of encryption for certain data in the devices, potentially allowing remote attackers to obtain sensitive information by...

7.5CVSS0.02221EPSS
SaveExploits0References6
Positive Technologies
Positive Technologies
•added 2016/10/05 12:00 a.m.•3 views

PT-2016-6640

Name of the Vulnerable Software and Affected Versions Johnson & Johnson Animas OneTouch Ping devices affected versions not specified Description The issue concerns the mishandling of acknowledgements in the custom communication protocol used by the devices, making it easier for remote attackers t...

9.8CVSS0.04519EPSS
SaveExploits0References5
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2016/10/05 12:00 a.m.•8 views

CVE-2016-5086: Improper Authentication

Johnson & Johnson Animas OneTouch Ping devices allow remote attackers to bypass authentication via replay attacks...

9.8CVSS5.8AI score0.04519EPSS
SaveExploits0References2
Positive Technologies
Positive Technologies
•added 2016/10/05 12:00 a.m.•3 views

PT-2016-6237

Name of the Vulnerable Software and Affected Versions Johnson & Johnson Animas OneTouch Ping devices affected versions not specified Description The issue allows remote attackers to bypass authentication via replay attacks. Recommendations At the moment, there is no information about a newer...

9.8CVSS0.04519EPSS
SaveExploits0References6
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2016/10/05 12:00 a.m.•8 views

CVE-2016-5084: Undefined Security Weakness

Johnson & Johnson Animas OneTouch Ping devices do not use encryption for certain data, which might allow remote attackers to obtain sensitive information by sniffing the network...

7.5CVSS5.9AI score0.02221EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2016/10/05 12:00 a.m.•7 views

CVE-2016-5686: Improper Authentication

Johnson & Johnson Animas OneTouch Ping devices mishandle acknowledgements, which makes it easier for remote attackers to bypass authentication via a custom communication protocol...

9.8CVSS5.8AI score0.04519EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2016/10/05 12:00 a.m.•8 views

CVE-2016-5085: Use of Insufficiently Random Values

Johnson & Johnson Animas OneTouch Ping devices do not properly generate random numbers, which makes it easier for remote attackers to spoof meters by sniffing the network and then engaging in an authentication handshake...

7.8CVSS5.9AI score0.03864EPSS
SaveExploits0References2
CERT
CERT
•added 2016/10/04 12:00 a.m.•51 views

Animas OneTouch Ping insulin pump contains multiple vulnerabilities

Overview The Animas OneTouch Ping insulin pump contains multiple vulnerabilities that may allow an unauthenticated remote attacker to obtain patient treatment or device data, or execute commands on the device. The attacker cannot obtain personally identifiable information. Description CWE-319:...

9.8CVSS9.4AI score0.04519EPSS
SaveExploits0References2
Kitploit
Kitploit
•added 2016/08/14 2:30 p.m.•675 views

Pentmenu - A simple Bash Script for Recon and DOS Attacks

A bash script inspired by pentbox. Designed to be a simple way to implement various network pentesting functions, including network attacks, using wherever possible readily available software commonly installed on most linux distributions without having to resort to multiple specialist tools. Sud...

5CVSS7AI score0.67189EPSS
SaveExploits1References2
Rows per page
Query Builder