Lucene search
+L

12524 matches found

Cvelist
Cvelist
•added 2022/06/15 5:35 p.m.•47 views

CVE-2017-20049

A vulnerability, was found in legacy Axis devices such as P3225 and M3005. This affects an unknown part of the component CGI Script. The manipulation leads to improper privilege management. It is possible to initiate the attack remotely...

9.6AI score0.01559EPSS
SaveExploits0References1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2022/06/15 12:00 a.m.•10 views

CVE-2017-20049: Improper Privilege Management

A vulnerability, was found in legacy Axis devices such as P3225 and M3005. This affects an unknown part of the component CGI Script. The manipulation leads to improper privilege management. It is possible to initiate the attack remotely...

10CVSS8AI score0.01559EPSS
SaveExploits0References2
Positive Technologies
Positive Technologies
•added 2022/06/15 12:00 a.m.•19 views

PT-2022-7922 · Axis · Axis Device

Name of the Vulnerable Software and Affected Versions: Axis devices affected versions not specified Description: A vulnerability was found in legacy Axis devices, affecting an unknown part of the component CGI Script. The manipulation leads to improper privilege management, and it is possible to...

10CVSS9.3AI score0.01559EPSS
SaveExploits0References4
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2022/06/14 12:00 a.m.•9 views

CVE-2022-31847: Direct Request

A vulnerability in /cgi-bin/ExportAllSettings.sh of WAVLINK WN579 X3 M79X3.V5030.180719 allows attackers to obtain sensitive router information via a crafted POST request...

7.5CVSS7.2AI score0.06555EPSS
SaveExploits3References2
GithubExploit
GithubExploit
•added 2022/06/13 9:11 p.m.•409 views

Exploit for OS Command Injection in Zyxel Usg_Flex_100W_Firmware

CVE-2022-30525 Zyxel Firewall Remote Command Injection A py...

10CVSS8.2AI score0.99944EPSS
SaveExploits27
OSV
OSV
•added 2022/06/13 6:15 p.m.•21 views

CVE-2022-33174

Power Distribution Units running on Powertek firmware multiple brands before 3.30.30 allows remote authorization bypass in the web interface. To exploit the vulnerability, an attacker must send an HTTP packet to the data retrieval interface /cgi/getparam.cgi with the tmpToken cookie set to an emp...

7.5CVSS5.8AI score0.14116EPSS
SaveExploits2References1
attackerkb
attackerkb
•added 2022/06/13 6:15 p.m.•12 views

CVE-2022-33174

Power Distribution Units running on Powertek firmware multiple brands before 3.30.30 allows remote authorization bypass in the web interface. To exploit the vulnerability, an attacker must send an HTTP packet to the data retrieval interface /cgi/getparam.cgi with the tmpToken cookie set to an emp...

9.8CVSS5.8AI score0.14116EPSS
SaveExploits2References3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2022/06/13 12:00 a.m.•11 views

CVE-2022-33175: Incorrect Permission Assignment for Critical Resource

Power Distribution Units running on Powertek firmware multiple brands before 3.30.30 have an insecure permissions setting on the user.token field that is accessible to everyone through the /cgi/getparam.cgi HTTP API. This leads to disclosing active session ids of currently logged-in administrator...

9.8CVSS8.2AI score0.01711EPSS
SaveExploits1References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2022/06/13 12:00 a.m.•7 views

CVE-2022-33174: Incorrect Authorization

Power Distribution Units running on Powertek firmware multiple brands before 3.30.30 allows remote authorization bypass in the web interface. To exploit the vulnerability, an attacker must send an HTTP packet to the data retrieval interface /cgi/getparam.cgi with the tmpToken cookie set to an emp...

9.8CVSS7.3AI score0.14116EPSS
SaveExploits2References2
CVE
CVE
•added 2022/06/11 1:26 p.m.•82 views

CVE-2021-41738

ZeroShell 3.9.5 is affected by a command injection in the /cgi-bin/kerbynet endpoint (IP parameter). An authenticated attacker could execute system commands through this parameter. Affected product/version: ZeroShell 3.9.5. Root cause: command injection via the IP parameter in kerbynet. Impact: p...

8.8CVSS8.7AI score0.01828EPSS
SaveExploits0References1Affected Software1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2022/06/11 12:00 a.m.•7 views

CVE-2021-41738: Improper Neutralization of Special Elements used in an OS Command

ZeroShell 3.9.5 has a command injection vulnerability in /cgi-bin/kerbynet IP parameter, which may allow an authenticated attacker to execute system commands...

8.8CVSS8AI score0.01828EPSS
SaveExploits0References2
CNVD
CNVD
•added 2022/06/09 12:00 a.m.•67 views

Barco Control Room Cross-Site Scripting Vulnerability

Barco Control Room is a visualization and collaboration solution from Barco Belgium. Used to build control rooms, a cross-site scripting vulnerability exists in the Barco Control Room Management Suite web application prior to version 3.14. The vulnerability stems from the URL parameter of the...

6.1CVSS2AI score0.00566EPSS
SaveExploits0References1
Exploit DB
Exploit DB
•added 2022/06/03 12:00 a.m.•266 views

Telesquare SDT-CW3B1 1.1.0 - OS Command Injection

!/usr/bin/python3 Exploit Title: Telesquare SDT-CW3B1 1.1.0 - OS Command Injection Date: 24th May 2022 Exploit Author: Bryan Leong Vendor Homepage: http://telesquare.co.kr/ CVE : CVE-2021-46422 Authentication Required: No import requests import argparse import sys from xml.etree import ElementTre...

10CVSS8.3AI score0.94425EPSS
SaveExploits21
attackerkb
attackerkb
•added 2022/06/02 10:00 p.m.•13 views

CVE-2022-31486

An authenticated attacker can send a specially crafted route to the “editroute.cgi” binary and have it execute shell commands. This vulnerability impacts products based on HID Mercury Intelligent Controllers LP1501, LP1502, LP2500, LP4502, and EP4502 which contain firmware versions prior to 1.303...

9CVSS5.7AI score0.01379EPSS
SaveExploits0References2
attackerkb
attackerkb
•added 2022/06/02 2:15 p.m.•15 views

CVE-2022-26972

Barco Control Room Management Suite web application, which is part of TransForm N before 3.14, is exposing a URL /cgi-bin endpoint. The URL parameters are not correctly sanitized, leading to reflected XSS...

6.1CVSS5.9AI score0.00566EPSS
SaveExploits0References3
OSV
OSV
•added 2022/06/02 2:15 p.m.•18 views

CVE-2022-26972

Barco Control Room Management Suite web application, which is part of TransForm N before 3.14, is exposing a URL /cgi-bin endpoint. The URL parameters are not correctly sanitized, leading to reflected XSS...

6.1CVSS6.4AI score0.00566EPSS
SaveExploits0References2
Positive Technologies
Positive Technologies
•added 2022/06/01 12:00 a.m.•3 views

PT-2022-18150

Name of the Vulnerable Software and Affected Versions Barco Control Room Management Suite web application version prior to 3.14 Description The issue is related to the exposure of a URL /cgi-bin endpoint in the web application, where URL parameters are not correctly sanitized. This leads to...

6.1CVSS0.00566EPSS
SaveExploits0References4
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2022/06/01 12:00 a.m.•6 views

CVE-2022-26972: Improper Neutralization of Input During Web Page Generation

Barco Control Room Management Suite web application, which is part of TransForm N before 3.14, is exposing a URL /cgi-bin endpoint. The URL parameters are not correctly sanitized, leading to reflected XSS...

6.1CVSS6.4AI score0.00566EPSS
SaveExploits0References2
OpenVAS
OpenVAS
•added 2022/05/25 12:00 a.m.•22 views

Huawei EulerOS: Security Advisory for ruby (EulerOS-SA-2022-1761)

The remote host is missing an update for the Huawei EulerOS SPDX-FileCopyrightText: 2022 Greenbone AG Some text descriptions might be excerpted from a referenced sources, and are Copyright C by the respective right holders. SPDX-License-Identifier: GPL-2.0-only ifdescription...

7.5CVSS7.9AI score0.02931EPSS
SaveExploits1References2
OSV
OSV
•added 2022/05/24 6:15 p.m.•17 views

CVE-2022-1669

A buffer overflow vulnerability has been detected in the firewall function of the device management web portal. The device runs a CGI binary index.cgi to offer a management web application. Once authenticated with valid credentials in this web portal, a potential attacker could submit any "Addres...

8.1CVSS6AI score0.00808EPSS
SaveExploits0References1
Rows per page
Query Builder