1693 matches found
Schneider-electric Modicon Use of Insufficiently Random Values
CWE-330: Use of Insufficiently Random Values vulnerability, which could cause the hijacking of the TCP connection when using Ethernet communication in Modicon M580 firmware versions prior to V2.30, and all firmware versions of Modicon M340, Modicon Premium, Modicon Quantum. File data ot500068.nas...
Schneider-electric Modicon Unspecified Vulnerability
A CWE-255 Credentials Management vulnerability exists in Modicon Quantum with firmware versions prior to V2.40. which could cause a Denial Of Service when using a Telnet connection. File data ot500126.nasl...
Schneider-electric Modicon Cleartext Transmission of Sensitive Information
A CWE-319: Cleartext Transmission of Sensitive Information vulnerability exists in Modicon M580, Modicon M340, Modicon BMxCRA and 140CRA modules all firmware versions, which could cause information disclosure when using the FTP protocol. File data ot500240.nasl...
Schneider-electric Modicon Improper Restriction of Operations within the Bounds of a Memory Buffer
The Schneider Electric M340 BMXNOE01xx and BMXP3420xx PLC modules allow remote authenticated users to cause a denial of service module crash via crafted FTP traffic, as demonstrated by the FileZilla FTP client. File data ot500046.nasl...
Schneider-electric Modicon Exposure of Sensitive Information to an Unauthorized Actor
A CWE-200: Information Exposure vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause the disclosure of SNMP information when reading files from the controller over Modbus File data ot500301.nasl...
Schneider-electric Modicon Cross-Site Request Forgery (CSRF)
Cross-site request forgery CSRF vulnerability on the Schneider Electric Quantum 140NOE77111, 140NOE77101, and 140NWM10000; M340 BMXNOC0401, BMXNOE0100x, and BMXNOE011xx; and Premium TSXETY4103, TSXETY5103, and TSXWMY100 PLC modules allows remote attackers to hijack the authentication of arbitrary...
Schneider-electric Modicon Exposure of Sensitive Information to an Unauthorized Actor
A CWE-200: Information Exposure vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause the disclosure of SNMP information when reading memory blocks from the controller over Modbus. File data ot500228.nasl...
Schneider-electric Modicon Use of Hard-coded Credentials
Schneider Electric SoMachine Basic 1.4 SP1 and Schneider Electric Modicon TM221CE16R 1.3.3.3 devices have a hardcoded-key vulnerability. The Project Protection feature is used to prevent unauthorized users from opening an XML protected project file, by prompting the user for a password. This XML...
Schneider-electric Modicon Unspecified Vulnerability
A CWE-290: Authentication Bypass by Spoofing vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause an elevation of privilege by conducting a brute force attack on Modbus parameters sent to the controller. File data...
Schneider-electric Modicon Improper Check for Unusual or Exceptional Conditions
An Improper Check for Unusual or Exceptional Conditions vulnerability exists in Schneider Electric's Modicon M221 product all references, all versions prior to firmware V1.6.2.0. The vulnerability allows unauthorized users to remotely reboot Modicon M221 using crafted programing protocol frames...
Schneider-electric Modicon Improper Restriction of Operations within the Bounds of a Memory Buffer
A CWE-501: Trust Boundary Violation vulnerability on connection to the Controller exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum and Modicon Premium which could cause unauthorized access by conducting a brute force attack on Modbus protocol to the controller. File data...
Schneider-electric Modicon Improper Handling of Exceptional Conditions
A CWE-248: Uncaught Exception vulnerability exists Modicon M580 firmware version prior to V2.90, Modicon M340 firmware version prior to V3.10, Modicon Premium all versions, and Modicon Quantum all versions, which could cause a possible denial of service when reading specific coils and registers i...
Schneider-electric Modicon Improper Handling of Exceptional Conditions
A CWE-248: Uncaught Exception vulnerability exists in Modicon M580, Modicon M340, Modicon BMxCRA and 140CRA modules all firmware versions, which could cause a Denial of Service attack on the PLC when upgrading the firmware with no firmware image inside the package using FTP protocol. File data...
Schneider-electric Modicon Improper Check for Unusual or Exceptional Conditions
A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a possible denial of Service when writing invalid memory blocks to the controller over Modbus. File data ot500124.nasl...
Schneider-electric Modicon Cleartext Transmission of Sensitive Information
A CWE-319: Cleartext Transmission of Sensitive Information vulnerability exists in Modicon M580, Modicon M340, Modicon Premium , Modicon Quantum all firmware versions, which could cause the disclosure of information when transferring applications to the controller using Modbus TCP protocol. File...
Schneider-electric Modicon Unspecified Vulnerability
In Modicon Quantum all firmware versions, CWE-264: Permissions, Privileges, and Access Control vulnerabilities could cause a denial of service or unauthorized modifications of the PLC configuration when using Ethernet/IP protocol. File data ot500069.nasl...
Schneider-electric Modicon Improper Check for Unusual or Exceptional Conditions
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in BMXNOR0200H Ethernet / Serial RTU module all firmware versions and Modicon M340 controller all firmware versions, which could cause denial of service when truncated SNMP packets on port 161/UDP are received by...
Schneider-electric Modicon Improper Input Validation
A CWE-248: Uncaught Exception vulnerability exists in Modicon M580, Modicon BMENOC 0311, and Modicon BMENOC 0321, which could cause a Denial of Service attack on the PLC when sending specific data on the REST API of the controller/communication module. File data ot500052.nasl...
Schneider-electric Modicon Exposure of Sensitive Information to an Unauthorized Actor
A CWE-200: Information Exposure vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause the disclosure of SNMP information when reading variables in the controller using Modbus. File data ot500316.nasl...
Schneider-electric Modicon Improper Check for Unusual or Exceptional Conditions
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists which could cause a possible Denial of Service when specific Modbus frames are sent to the controller in the products: Modicon M340 - firmware versions prior to V3.01, Modicon M580 - firmware versions prior to...