Lucene search
+L

1957 matches found

CVE
CVE
•added 2023/01/30 12:00 a.m.•115 views

CVE-2022-45788

Schneider Electric’s CVE-2022-45788 affects EcoStruxure Control Expert, EcoStruxure Process Expert, and multiple Modicon CPU families (M340 BMXP34*, M580 BMEP*/BMEH*, M580 Safety BMEP58*/BMEH58*, Momentum Unity 171CBU*, MC80 BMKC80, Legacy Quantum 140CPU65* and Premium TSXP57*; all versions prior...

9.8CVSS9.5AI score0.01173EPSS
SaveExploits0References1Affected Software2
Tenable Nessus
Tenable Nessus
•added 2023/01/25 12:00 a.m.•34 views

Phoenix Contact PLC Cycle Time Influences Uncontrolled Resource Consumption (CVE-2019-10953)

ABB, Phoenix Contact, Schneider Electric, Siemens, WAGO - Programmable Logic Controllers, multiple versions. Researchers have found some controllers are susceptible to a denial-of-service attack due to a flood of network packets. This plugin only works with Tenable.ot. Please visit...

7.5AI score0.03395EPSS
SaveExploits0References3
BDU FSTEC
BDU FSTEC
•added 2023/01/13 12:00 a.m.•16 views

The vulnerability of the Web Server software on Schneider Electric’s programmable logic controllers, such as Modicon M340, Modicon Quantum, and Modicon Premium, allows attackers to disclose sensitive information or cause malfunctions in the equipment.

The vulnerability of the Web Server component of Schneider Electric’s programmable logic controllers—Modicon M340, Modicon Quantum, and Modicon Premium—is due to buffer overflow attacks. Exploiting this vulnerability allows an attacker to disclose sensitive information or cause service failures b...

8.5CVSS7.7AI score0.00902EPSS
SaveExploits0References4Affected Software3
Positive Technologies
Positive Technologies
•added 2023/01/10 12:00 a.m.•16 views

PT-2023-1079 · Schneider Electric · Modicon M580 Cpu +7

Name of the Vulnerable Software and Affected Versions: EcoStruxure Control Expert All Versions EcoStruxure Process Expert All Versions Modicon M340 CPU - part numbers BMXP34 All Versions Modicon M580 CPU - part numbers BMEP and BMEH All Versions Modicon M580 CPU Safety - part numbers BMEP58S and...

9.8CVSS9.7AI score0.01173EPSS
SaveExploits0References10
Positive Technologies
Positive Technologies
•added 2023/01/10 12:00 a.m.•14 views

PT-2023-1236 · Schneider Electric · Ecostruxure Process Expert +4

Name of the Vulnerable Software and Affected Versions: EcoStruxure Control Expert versions prior to V2020 EcoStruxure Process Expert versions prior to V2020 Modicon M340 CPU versions prior to the latest version Modicon M580 CPU versions prior to the latest version Modicon M580 CPU Safety versions...

9.8CVSS9.3AI score0.01455EPSS
SaveExploits0References10
ICS
ICS
•added 2023/01/10 12:00 a.m.•90 views

Schneider Electric EcoStruxure Control Expert, Process Expert, Modicon M340, M580 and M580 CPU (Update A)

1. EXECUTIVE SUMMARY CVSS v3 8.1 ATTENTION: Exploitable remotely Vendor: Schneider Electric Equipment: EcoStruxure Control Expert, EcoStruxure Process Expert, Modicon M340 CPU, Modicon M580 CPU, Modicon Momentum Unity M1E Processor, Modicon MC80 Vulnerability: Authentication Bypass by...

9.8CVSS7.5AI score0.01455EPSS
SaveExploits0References11
Tenable Nessus
Tenable Nessus
•added 2022/12/19 12:00 a.m.•59 views

Schneider Electric Modicon Improper Privilege Management (CVE-2022-0222)

A CWE-269: Improper Privilege Management vulnerability exists that could cause a denial of service of the Ethernet communication of the controller when sending a specific request over SNMP. Affected products: Modicon M340 CPUsBMXP34 versions prior to V3.40, Modicon M340 X80 Ethernet Communication...

7.5CVSS7.3AI score0.00607EPSS
SaveExploits0References2
BDU FSTEC
BDU FSTEC
•added 2022/12/14 12:00 a.m.•21 views

The vulnerability of microprogrammed software in Schneider Electric’s programmable logic controllers, such as Modicon M340 and Modicon Quantum/Premium, arises from insufficient protection of operational data. This allows attackers to gain unauthorized access to protected information.

The vulnerability of microprogrammed software in Schneider Electric Modicon M340 and Modicon Quantum/Premium programmable logic controllers is related to insufficient protection of operational data. Exploiting this vulnerability can allow unauthorized individuals to gain unauthorized access to...

7.8CVSS7.2AI score0.00962EPSS
SaveExploits0References3Affected Software2
BDU FSTEC
BDU FSTEC
•added 2022/12/14 12:00 a.m.•15 views

The vulnerability of microprogrammed software in Schneider Electric’s programmable logic controllers, such as Modicon M340 and Modicon Quantum/Premium, arises from the possibility of an operation exceeding the buffer limits. This allows a malicious actor to trigger a service failure.

The vulnerability of microprogrammed software in Schneider Electric Modicon M340 and Modicon Quantum/Premium programmable logic controllers lies in the execution of operations outside the buffer boundaries. Exploiting this vulnerability can allow a malicious actor to cause service failures by...

7.8CVSS7.6AI score0.01037EPSS
SaveExploits0References3Affected Software2
Tenable Nessus
Tenable Nessus
•added 2022/12/07 12:00 a.m.•37 views

Schneider Electric Modicon Integer Underflow (CVE-2022-37301)

A CWE-191: Integer Underflow Wrap or Wraparound vulnerability exists that could cause a denial of service of the controller due to memory access violations when using the Modbus TCP protocol. Affected products: Modicon M340 CPU part numbers BMXP34V3.40 and prior, Modicon M580 CPU part numbers BME...

7.5CVSS7.3AI score0.00754EPSS
SaveExploits0References2
CNVD
CNVD
•added 2022/11/24 12:00 a.m.•42 views

Schneider Electric Product Authorization Issue Vulnerability

The Schneider Electric Modicon M340 is a mid-range PLC Programmable Logic Controller for industrial processes and infrastructures from Schneider Electric France. An authorization issue vulnerability exists in the Schneider Electric product that stems from the presence of improper privilege...

7.5CVSS7.5AI score0.00607EPSS
SaveExploits0References1
CNVD
CNVD
•added 2022/11/24 12:00 a.m.•100 views

Schneider Electric Product Numerical Error Vulnerability

The Schneider Electric Modicon M340 is a mid-range PLC programmable logic controller for industrial processes and infrastructure from Schneider Electric, France. The Schneider Electric product suffers from a numeric error vulnerability that originates from a memory access conflict, which can be...

7.5CVSS7.4AI score0.00754EPSS
SaveExploits0References1
OSV
OSV
•added 2022/11/22 1:15 p.m.•16 views

CVE-2022-0222

A CWE-269: Improper Privilege Management vulnerability exists that could cause a denial of service of the Ethernet communication of the controller when sending a specific request over SNMP. Affected products: Modicon M340 CPUsBMXP34 versions prior to V3.40, Modicon M340 X80 Ethernet Communication...

7.5CVSS5.8AI score0.00607EPSS
SaveExploits0References1
NVD
NVD
•added 2022/11/22 1:15 p.m.•27 views

CVE-2022-0222

A CWE-269: Improper Privilege Management vulnerability exists that could cause a denial of service of the Ethernet communication of the controller when sending a specific request over SNMP. Affected products: Modicon M340 CPUsBMXP34 versions prior to V3.40, Modicon M340 X80 Ethernet Communication...

7.5CVSS0.00607EPSS
SaveExploits0References1
Prion
Prion
•added 2022/11/22 1:15 p.m.•32 views

Privilege escalation

A CWE-269: Improper Privilege Management vulnerability exists that could cause a denial of service of the Ethernet communication of the controller when sending a specific request over SNMP. Affected products: Modicon M340 CPUsBMXP34 versions prior to V3.40, Modicon M340 X80 Ethernet Communication...

5CVSS7.3AI score0.00607EPSS
SaveExploits0References1Affected Software10
OSV
OSV
•added 2022/11/22 12:15 p.m.•18 views

CVE-2022-37301

A CWE-191: Integer Underflow Wrap or Wraparound vulnerability exists that could cause a denial of service of the controller due to memory access violations when using the Modbus TCP protocol. Affected products: Modicon M340 CPU part numbers BMXP34V3.40 and prior, Modicon M580 CPU part numbers BME...

7.5CVSS5.8AI score0.00754EPSS
SaveExploits0References1
NVD
NVD
•added 2022/11/22 12:15 p.m.•43 views

CVE-2022-37301

A CWE-191: Integer Underflow Wrap or Wraparound vulnerability exists that could cause a denial of service of the controller due to memory access violations when using the Modbus TCP protocol. Affected products: Modicon M340 CPU part numbers BMXP34V3.40 and prior, Modicon M580 CPU part numbers BME...

7.5CVSS0.00754EPSS
SaveExploits0References1
Prion
Prion
•added 2022/11/22 12:15 p.m.•30 views

Integer overflow

A CWE-191: Integer Underflow Wrap or Wraparound vulnerability exists that could cause a denial of service of the controller due to memory access violations when using the Modbus TCP protocol. Affected products: Modicon M340 CPU part numbers BMXP34V3.40 and prior, Modicon M580 CPU part numbers BME...

5CVSS7.4AI score0.00754EPSS
SaveExploits0References1Affected Software30
CNNVD
CNNVD
•added 2022/11/22 12:00 a.m.•18 views

Schneider Electric Modicon M340 数字错误漏洞

The Schneider Electric Modicon M340 is a mid-range PLC programmable logic controller for industrial processes and infrastructure from Schneider Electric, France. The Schneider Electric product suffers from a numeric error vulnerability that originates from a memory access conflict, which can be...

7.5CVSS6.7AI score0.00754EPSS
SaveExploits0References2
CNNVD
CNNVD
•added 2022/11/22 12:00 a.m.•21 views

Schneider Electric Modicon M340 安全漏洞

The Schneider Electric Modicon M340 is a mid-range PLC Programmable Logic Controller for industrial processes and infrastructures from Schneider Electric France. An authorization issue vulnerability exists in the Schneider Electric product that stems from the presence of improper privilege...

7.5CVSS6.8AI score0.00607EPSS
SaveExploits0References2
Rows per page