CVE-2018-7242: Inadequate Encryption Strength
Vulnerable hash algorithms exists in Schneider Electric's Modicon Premium, Modicon Quantum, Modicon M340, and BMXNOR0200 controllers in all versions of the communication modules. The algorithm used to encrypt the password is vulnerable to hash collision attacks...
CVE-2018-7760: Improper Authentication
An authorization bypass vulnerability exists in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200. Requests to CGI functions allow malicious users to bypass authorization...
CVE-2018-7759: Improper Restriction of Operations within the Bounds of a Memory Buffer
A buffer overflow vulnerability exists in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200. The buffer overflow vulnerability is caused by the length of the source string specified instead of the buffer size as the number of bytes to be copied...
CVE-2018-7761: Improper Input Validation
A vulnerability exists in the HTTP request parser in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200 which could allow arbitrary code execution...
CVE-2018-7762: Improper Restriction of Operations within the Bounds of a Memory Buffer
A vulnerability exists in the web services to process SOAP requests in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200 which could allow result in a buffer overflow...
CVE-2018-7241: Use of Hard-coded Credentials
Hard coded accounts exist in Schneider Electric's Modicon Premium, Modicon Quantum, Modicon M340, and BMXNOR0200 controllers in all versions of the communication modules...
Stack Buffer Overflow Vulnerability in Various Schneider Electric Products
Schneider Electric Modicon Premium\Modicon Quantum\Modicon M340\Modicon BMXNOR0200 are programmable controllers from Schneider Electric, France. A stack buffer overflow vulnerability exists in various Schneider Electric products, which stems from the FTP server not limiting the length of the...
Schneider Electric uses hard-coded certificate vulnerability in several products
Schneider Electric Modicon Premium\Modicon Quantum\Modicon M340\Modicon BMXNOR0200 are programmable controllers from Schneider Electric, France. A hard-coded certificate vulnerability exists in various Schneider Electric products, which stems from an FTP server containing a hard-coded account tha...
Weak Encryption Algorithm Vulnerability in Various Schneider Electric Products
Schneider Electric Modicon Premium\Modicon Quantum\Modicon M340\Modicon BMXNOR0200 are programmable controllers from Schneider Electric, France. A weak cryptographic algorithm vulnerability exists in various Schneider Electric products, which stems from the FTP server not limiting the length of...
Schneider Electric Modicon Premium, Modicon Quantum, Modicon M340, and Modicon BMXNOR0200
CVSS v3 5.9 ATTENTION: Exploitable remotely/low skill level to exploit. Vendor: Schneider Electric Equipment: Modicon Premium, Modicon Quantum, Modicon M340, and Modicon BMXNOR0200 Vulnerabilities: Stack-based Buffer Overflow, Use of Hard-coded Credentials, Use of a Broken or Risky Cryptographic...
PT-2018-1294 · Schneider Electric · Modicon M340 +3
Name of the Vulnerable Software and Affected Versions: Schneider Electric's Modicon Premium, Modicon Quantum, Modicon M340, and BMXNOR0200 controllers affected versions not specified Description: The issue is related to hard-coded accounts in the communication modules of the affected controllers...
CVE-2017-6030
A Predictable Value Range from Previous Values issue was discovered in Schneider Electric Modicon PLCs Modicon M221, firmware versions prior to Version 1.5.0.0, Modicon M241, firmware versions prior to Version 4.0.5.11, and Modicon M251, firmware versions prior to Version 4.0.5.11. The affected...
CVE-2017-6028
An Insufficiently Protected Credentials issue was discovered in Schneider Electric Modicon PLCs Modicon M241, all firmware versions, and Modicon M251, all firmware versions. Log-in credentials are sent over the network with Base64 encoding leaving them susceptible to sniffing. Sniffed credentials...
Code injection
A Predictable Value Range from Previous Values issue was discovered in Schneider Electric Modicon PLCs Modicon M221, firmware versions prior to Version 1.5.0.0, Modicon M241, firmware versions prior to Version 4.0.5.11, and Modicon M251, firmware versions prior to Version 4.0.5.11. The affected...
Design/Logic Flaw
A Violation of Secure Design Principles issue was discovered in Schneider Electric Modicon Modbus Protocol. The Modicon Modbus protocol has a session-related weakness making it susceptible to brute-force attacks...
Design/Logic Flaw
An Insufficiently Protected Credentials issue was discovered in Schneider Electric Modicon PLCs Modicon M241, all firmware versions, and Modicon M251, all firmware versions. Log-in credentials are sent over the network with Base64 encoding leaving them susceptible to sniffing. Sniffed credentials...
Authentication flaw
An Authentication Bypass by Capture-Replay issue was discovered in Schneider Electric Modicon Modbus Protocol. Sensitive information is transmitted in cleartext in the Modicon Modbus protocol, which may allow an attacker to replay the following commands: run, stop, upload, and download...
CVE-2017-6026
A Use of Insufficiently Random Values issue was discovered in Schneider Electric Modicon PLCs Modicon M241, firmware versions prior to Version 4.0.5.11, and Modicon M251, firmware versions prior to Version 4.0.5.11. The session numbers generated by the web application are lacking randomization an...
CVE-2017-6030
A predictable value range from previous values issue was discovered in Schneider Electric Modicon PLCs Modicon M221, firmware versions prior to Version 1.5.0.0, Modicon M241, firmware versions prior to Version 4.0.5.11, and Modicon M251, firmware versions prior to Version 4.0.5.11. The affected...
CVE-2017-6032
A Violation of Secure Design Principles issue was discovered in Schneider Electric Modicon Modbus Protocol. The Modicon Modbus protocol has a session-related weakness making it susceptible to brute-force attacks...