1688 matches found
CVE-2018-7759
CVE-2018-7759 describes a buffer overflow in Schneider Electric Modicon M340, Premium, Quantum PLCs and BMXNOR0200 caused by using the length of the source string (not the buffer size) as the copy size. This vulnerability can enable a remote attacker to cause a denial of service. A vendor advisor...
Weak Encryption Algorithm Vulnerability in Various Schneider Electric Products
Schneider Electric Modicon Premium\Modicon Quantum\Modicon M340\Modicon BMXNOR0200 are programmable controllers from Schneider Electric, France. A weak cryptographic algorithm vulnerability exists in various Schneider Electric products, which stems from the FTP server not limiting the length of...
Schneider Electric uses hard-coded certificate vulnerability in several products
Schneider Electric Modicon Premium\Modicon Quantum\Modicon M340\Modicon BMXNOR0200 are programmable controllers from Schneider Electric, France. A hard-coded certificate vulnerability exists in various Schneider Electric products, which stems from an FTP server containing a hard-coded account tha...
Stack Buffer Overflow Vulnerability in Various Schneider Electric Products
Schneider Electric Modicon Premium\Modicon Quantum\Modicon M340\Modicon BMXNOR0200 are programmable controllers from Schneider Electric, France. A stack buffer overflow vulnerability exists in various Schneider Electric products, which stems from the FTP server not limiting the length of the...
Schneider Electric Modicon Premium, Modicon Quantum, Modicon M340, and Modicon BMXNOR0200
CVSS v3 5.9 ATTENTION: Exploitable remotely/low skill level to exploit. Vendor: Schneider Electric Equipment: Modicon Premium, Modicon Quantum, Modicon M340, and Modicon BMXNOR0200 Vulnerabilities: Stack-based Buffer Overflow, Use of Hard-coded Credentials, Use of a Broken or Risky Cryptographic...
PT-2018-1294 · Schneider Electric · Modicon M340 +3
Name of the Vulnerable Software and Affected Versions: Schneider Electric's Modicon Premium, Modicon Quantum, Modicon M340, and BMXNOR0200 controllers affected versions not specified Description: The issue is related to hard-coded accounts in the communication modules of the affected controllers...
CVE-2017-6017
A Resource Exhaustion issue was discovered in Schneider Electric Modicon M340 PLC BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP341000, BMXP342000, BMXP3420102, BMXP3420102CL, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H, and BMXP342030H. A remote attacker...
Design/Logic Flaw
A Violation of Secure Design Principles issue was discovered in Schneider Electric Modicon Modbus Protocol. The Modicon Modbus protocol has a session-related weakness making it susceptible to brute-force attacks...
CVE-2017-6026
A Use of Insufficiently Random Values issue was discovered in Schneider Electric Modicon PLCs Modicon M241, firmware versions prior to Version 4.0.5.11, and Modicon M251, firmware versions prior to Version 4.0.5.11. The session numbers generated by the web application are lacking randomization an...
CVE-2017-6017
A Resource Exhaustion issue was discovered in Schneider Electric Modicon M340 PLC BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP341000, BMXP342000, BMXP3420102, BMXP3420102CL, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H, and BMXP342030H. A remote attacker...
Authentication flaw
An Authentication Bypass by Capture-Replay issue was discovered in Schneider Electric Modicon Modbus Protocol. Sensitive information is transmitted in cleartext in the Modicon Modbus protocol, which may allow an attacker to replay the following commands: run, stop, upload, and download...
CVE-2017-6034
An authentication bypass by capture-replay issue was discovered in Schneider Electric Modicon Modbus Protocol. Sensitive information is transmitted in cleartext in the Modicon Modbus protocol, which may allow an attacker to replay the following commands: run, stop, upload, and download...
CVE-2017-6032
A Violation of Secure Design Principles issue was discovered in Schneider Electric Modicon Modbus Protocol. The Modicon Modbus protocol has a session-related weakness making it susceptible to brute-force attacks...
Session fixation
A Use of Insufficiently Random Values issue was discovered in Schneider Electric Modicon PLCs Modicon M241, firmware versions prior to Version 4.0.5.11, and Modicon M251, firmware versions prior to Version 4.0.5.11. The session numbers generated by the web application are lacking randomization an...
CVE-2017-6028
An Insufficiently Protected Credentials issue was discovered in Schneider Electric Modicon PLCs Modicon M241, all firmware versions, and Modicon M251, all firmware versions. Log-in credentials are sent over the network with Base64 encoding leaving them susceptible to sniffing. Sniffed credentials...
CVE-2017-6026
A Use of Insufficiently Random Values issue was discovered in Schneider Electric Modicon PLCs Modicon M241, firmware versions prior to Version 4.0.5.11, and Modicon M251, firmware versions prior to Version 4.0.5.11. The session numbers generated by the web application are lacking randomization an...
Code injection
A Predictable Value Range from Previous Values issue was discovered in Schneider Electric Modicon PLCs Modicon M221, firmware versions prior to Version 1.5.0.0, Modicon M241, firmware versions prior to Version 4.0.5.11, and Modicon M251, firmware versions prior to Version 4.0.5.11. The affected...
CVE-2017-6030
A predictable value range from previous values issue was discovered in Schneider Electric Modicon PLCs Modicon M221, firmware versions prior to Version 1.5.0.0, Modicon M241, firmware versions prior to Version 4.0.5.11, and Modicon M251, firmware versions prior to Version 4.0.5.11. The affected...
CVE-2017-6030
A Predictable Value Range from Previous Values issue was discovered in Schneider Electric Modicon PLCs Modicon M221, firmware versions prior to Version 1.5.0.0, Modicon M241, firmware versions prior to Version 4.0.5.11, and Modicon M251, firmware versions prior to Version 4.0.5.11. The affected...
Design/Logic Flaw
A Resource Exhaustion issue was discovered in Schneider Electric Modicon M340 PLC BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP341000, BMXP342000, BMXP3420102, BMXP3420102CL, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H, and BMXP342030H. A remote attacker...