Multiple security vulnerabilities has been discovered in web interface of NetGuardian DIN Remote Telemetry Unit (RTU), by DPS Telecom. Attackers can exploit those security vulnerabilities to perform critical actions such as escalate user's privilege, steal user's credential, Cross Site Scripting...
7.6CVSS
6.9AI Score
0.0004EPSS
This privilege escalation vulnerability, if exploited, cloud allow a local OS-authenticated user with standard privileges to escalate to System privilege on the machine where these products are installed, resulting in complete compromise of the target...
7.8CVSS
7.8AI Score
0.0004EPSS
This external control vulnerability, if exploited, could allow a local OS-authenticated user with standard privileges to delete files with System privilege on the machine where these products are installed, resulting in denial of...
7.1CVSS
6.8AI Score
0.0004EPSS
The HTTP/2 protocol allows a denial of service (server resource consumption) because request cancellation can reset many streams quickly, as exploited in the wild in August through October...
The listed versions of AVEVA Plant SCADA and AVEVA Telemetry Server are vulnerable to an improper authorization exploit which could allow an unauthenticated user to remotely read data, cause denial of service, and tamper with alarm...
9.8CVSS
9.2AI Score
0.002EPSS
An issue was discovered in the telemetry crate through 2021-02-17 for Rust. There is a drop of uninitialized memory if a value.clone() call panics within...
9.8CVSS
9.4AI Score
0.005EPSS
SAE IT-systems FW-50 Remote Telemetry Unit (RTU). The software does not neutralize or incorrectly neutralizes user-controllable input before it is placed in the output used as a webpage that is served to other...
6.1CVSS
6.8AI Score
0.001EPSS
SAE IT-systems FW-50 Remote Telemetry Unit (RTU). A specially crafted request could allow an attacker to view the file structure of the affected device and access files that should be...
9.1CVSS
9.1AI Score
0.002EPSS
In ApexPro Telemetry Server Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE Central Station (CSCS) Versions 1.X, the affected products utilize a weak encryption scheme for remote desktop control, which may allow an.....
10CVSS
9.6AI Score
0.01EPSS
In ApexPro Telemetry Server Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE Central Station (CSCS) Versions 1.X, B450 Version 2.X, B650 Version 1.X, B650 Version 2.X, B850 Version 1.X, B850 Version 2.X, a...
9.9CVSS
9AI Score
0.001EPSS
In ApexPro Telemetry Server, Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE Telemetry Server Version 4.3, CARESCAPE Central Station (CSCS) Versions 1.X CARESCAPE Central Station (CSCS) Versions 2.X, B450 Version...
10CVSS
9.5AI Score
0.01EPSS
In ApexPro Telemetry Server Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE Central Station (CSCS) Versions 1.X, the affected products utilized hard coded SMB credentials, which may allow an attacker to remotely...
10CVSS
9.4AI Score
0.005EPSS
In ApexPro Telemetry Server, Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE Telemetry Server Version 4.3, CARESCAPE Central Station (CSCS) Versions 1.X, a vulnerability exists in the affected products that could...
10CVSS
9.1AI Score
0.003EPSS
In ApexPro Telemetry Server Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE Central Station (CSCS) Versions 1.X and CARESCAPE Central Station (CSCS) Versions 2.X, the integrated service for keyboard switching of the....
8.6CVSS
8.5AI Score
0.001EPSS
The Conexus telemetry protocol utilized within Medtronic MyCareLink Monitor versions 24950 and 24952, CareLink Monitor version 2490C, CareLink 2090 Programmer, Amplia CRT-D, Claria CRT-D, Compia CRT-D, Concerto CRT-D, Concerto II CRT-D, Consulta CRT-D, Evera ICD, Maximo II CRT-D and ICD, Mirro...
6.5CVSS
6.3AI Score
0.001EPSS
The Conexus telemetry protocol utilized within Medtronic MyCareLink Monitor versions 24950 and 24952, CareLink Monitor version 2490C, CareLink 2090 Programmer, Amplia CRT-D, Claria CRT-D, Compia CRT-D, Concerto CRT-D, Concerto II CRT-D, Consulta CRT-D, Evera ICD, Maximo II CRT-D and ICD, Mirro...
6.5CVSS
6.4AI Score
0.001EPSS
An Inadequate Encryption Strength issue was discovered in Mirion Technologies DMC 3000 Transmitter Module, iPam Transmitter f/DMC 2000, RDS-31 iTX and variants (including RSD31-AM Package), DRM-1/2 and variants (including Solar PWR Package), DRM and RDS Based Boundary Monitors, External...
6.5CVSS
6.5AI Score
0.001EPSS
A Use of Hard-Coded Cryptographic Key issue was discovered in Mirion Technologies DMC 3000 Transmitter Module, iPam Transmitter f/DMC 2000, RDS-31 iTX and variants (including RSD31-AM Package), DRM-1/2 and variants (including Solar PWR Package), DRM and RDS Based Boundary Monitors, External...
5CVSS
5.2AI Score
0.001EPSS
An issue was discovered in Adcon Telemetry A850 Telemetry Gateway Base Station. The Web Interface does not neutralize or incorrectly neutralizes user-controllable input before it is placed in the output; this could allow for cross-site...
6.1CVSS
6AI Score
0.001EPSS
The Java client in Adcon Telemetry A840 Telemetry Gateway Base Station allows remote attackers to discover log-file pathnames via unspecified...
8.6CVSS
8.3AI Score
0.003EPSS
Adcon Telemetry A840 Telemetry Gateway Base Station allows remote attackers to obtain sensitive information by sniffing the...
8.6CVSS
8.2AI Score
0.002EPSS
The Java client in Adcon Telemetry A840 Telemetry Gateway Base Station does not authenticate the station device, which allows man-in-the-middle attackers to spoof devices and obtain sensitive information by reading cleartext packet data, related to the lack of SSL...
8.7CVSS
8.2AI Score
0.001EPSS
Adcon Telemetry A840 Telemetry Gateway Base Station has hardcoded credentials, which allows remote attackers to obtain administrative access via unspecified...
10CVSS
9.1AI Score
0.005EPSS
Exemys Telemetry Web Server relies on an HTTP Location header to indicate that a client is unauthorized, which allows remote attackers to bypass intended access restrictions by disregarding this header and processing the response...
6.9AI Score
0.003EPSS
The notifier middleware in OpenStack PyCADF 0.5.0 and earlier, Telemetry (Ceilometer) 2013.2 before 2013.2.4 and 2014.x before 2014.1.2, Neutron 2014.x before 2014.1.2 and Juno before Juno-2, and Oslo allows remote authenticated users to obtain X_AUTH_TOKEN values by reading the message queue...
5.9AI Score
0.006EPSS