Defcom Labs Advisory def-2001-06  
  
Easycom/Safecom 10/100 Multiple DoS  
  
Author: Peter Gründl <[email protected]>  
Release Date: 2001-01-23  
======================================================================  
------------------------=[Brief Description]=-------------------------  
The Easycom/Safecom print server from I-Data International contains  
multiple vulnerabilites that allow a malicious user to bring down the  
print server. Execution of arbitrary code is also possible.  
  
------------------------=[Affected Systems]=--------------------------  
- Easycom/Safecom, firmware 404.590  
- Most likely older firmware revisions as well  
  
----------------------=[Detailed Description]=------------------------  
The print server has a web service running on port 80 and on port 631.  
Both are vulnerable to a long URL request. The long URL results in a  
buffer overflow on the server. The effect can either be that the unit  
crashes or execution of arbitrary code on the server.  
  
The PrintGuide service on port 5742 will cease to respond, if you send  
two bursts (80 connects in each burst) of null characters to the port.  
  
The FTP service on TCP port 21 is vulnerable to data flooding. The  
flooding results in the unit being disconnected from the network.  
  
The web services on port 80 and port 631 are both vulnerable to long  
HTTP requests. An infinite HTTP request will result in the unit being  
disconnected from the network. This is done by eg. issuing a normal  
GET request and filling A's into an HTTP header field, like "host:".  
  
The TCP/IP implementation on the Easycom/Safecom unit is vulnerable  
to flooding. Sending large burst of "normal" network packets to the  
unit at eg. 10 mbit will result in the unit being disconnected from  
the network.  
  
---------------------------=[Workaround]=-----------------------------  
No vendor supplied workaround known. You could put your unit behind a  
filtering router, and make sure the ports aren't accessible from the  
network (except from the managing console, of course).  
  
-------------------------=[Vendor Response]=--------------------------  
This issue was brought to the vendor's attention on the 30th of  
November, 2000. Vendor promises to look into it, but has not yet come  
up with any indication on when a fix would be available.  
  
======================================================================  
This release was brought to you by Defcom Labs  
  
[email protected] www.defcom.com  
======================================================================  
  
  
  
`

Data

Build on a solid foundation with Vulners data

We provide the essential building blocks for cybersecurity solutions with comprehensive, structured, and constantly updated vulnerability and exploits data

Api

Power your application with Vulners API

The Vulners REST API offers reliable, high-performance access to vulnerability intelligence, with 99.9% SLA uptime and CDN-backed data delivery for seamless global access

App

Assess and manage vulnerabilities with Vulners tools

Built on top of Vulners' database and SDK, end-user solutions give security professionals and developers lightweight and powerful tools for vulnerability remediation

02 Feb 2001 00:00Current
7.4High risk
Vulners AI Score7.4
33