cman security, bug fix, and enhancement update

2009-09-08T00:00:00
ID ELSA-2009-1341
Type oraclelinux
Reporter Oracle
Modified 2009-09-08T00:00:00

Description

[2.0.115-1] - RSA II fencing agent has been fixed. - Resolves: rhbz#493802 [2.0.114-1] - local variable 'verbose_filename' referenced before assignment has been fixed - RSA II fencing agent has been fixed. - Resolves: rhbz#493802 rhbz#514758 [2.0.113-1] - Limitations with 2-node fence_scsi are now properly documented in the man page. - Resolves: rhbz#512998 [2.0.112-1] - The pexpect exception is now properly checked in fence agents. - Resolves: rhbz#501586 [2.0.111-1] - cman_tool leave remove does now properly reduces quorum. - Resolves: rhbz#505258 [2.0.110-1] - Updated fence_lpar man page to remove options that do not yet exist. - Resolves: rhbz#498045 [2.0.108-1] - A semaphore leak in cman has been fixed. - Resolves: rhbz#505594 [2.0.107-1] - Added man page for lpar fencing agent (fence_lpar). - Resolves: rhbz#498045 [2.0.106-1] - The lssyscfg command can take longer than the shell timeout which will cause fencing to fail, we now wait longer for the lssyscfg command to complete. - Resolves: rhbz#504705 [2.0.105-1] - The fencing agents no longer fail with pexpect exceptions. - Resolves: rhbz#501586 [2.0.104-1] - Broadcast communcations are now possible with cman - fence_lpar can now login to IVM systems - Resolves: rhbz#502674 rhbz#492808 [2.0.103-1] - fence_apc no longer fails with a pexpect exception - symlink vulnerabilities in fance_apc_snmp were fixed - The virsh fencing agent was added. - Resolves: rhbz#496629 rhbz#498952 rhbz#501586 [2.0.102-1] - Correct return code is checked during disk scanning check. - Resolves: rhbz#484956 [2.0.101-1] - The SCSI fence agent now verifies that sg_persist is installed properly. - The DRAC5 fencing agent now properly handles a modulename. - QDisk now logs warning messages if it appears it's I/O to shared storage is hung. - Resolves: rhbz#496724 rhbz#500450 rhbz#500567 [2.0.100-1] - Support has been added for ePowerSwitch 8+ devices - cluster.conf files can now have more than 52 entries inside a block inside [block] - The output of the group_tool dump sub commands are no longer NULL padded. - Using device='' instead of label='' no longer causes qdiskd to incorrectly exit - The IPMI fencing agent has been modified to timeout after 10 seconds. It is also now possible to specify a different timeout with the '-t' option. - The IPMI fencing agent now allows punctuation in the password - Quickly starting and stopping the cman service no longer causes the cluster membership to become inconsistent across the cluster - An issue with lock syncing causing 'receive_own from ...' errors in syslog has been fixed - An issue which caused gfs_controld to segfault when mounting hundreds of filesystems has been fixed - The LPAR fencing agent now properly reports status when an LPAR is in Open Firmware - The APC SNMP fencing agent now properly recognizes outletStatusOn and outletStatusOff returns codes from the SNMP agent - WTI Fencing agent can now connect to fencing devices with no password - The rps-10 fencing agent now properly performs a reboot when run with no options. - The IPMI fencing agent now supports different cipher types with the '-C' option - Qdisk now properly scans devices and partitions - Added support for LPAR/HMC v3 - cman now checks to see if a new node has state to prevent killing the first node during cluster setup - service qdiskd start now works properly - The McData fence agent now works properly with the Sphereon 4500 model - The Egenera fence agent can now specify an ssh login name - APC Fence agent works with non-admin accounts with firmware 3.5.x - fence_xvmd now tries two methods to reboot a virtual machine - Connections to openais are now allowed from unprivileged CPG clients with user and group of 'ais' - Support has been added for Cisco 9124/9134 SAN switches - groupd no longer allows the default fence domain to be '0' which would cause rgmanager to hang - The RSA fence agent now supports ssh enabled RSA II devices - DRAC fence agent now works with iDRAC on the Dell M600 Blade Chassis - fence_drac5 now shows proper usage instructions - cman no longer uses the wrong node name when getnameinfo() fails - The SCSI fence agent now verifies that sg_persist is installed properly - Resolves: rhbz#467112 rhbz#468966 rhbz#470318 rhbz#276541 rhbz#447964 rhbz#472786 rhbz#474163 rhbz#480401 rhbz#481566 rhbz#484095 rhbz#481664 rhbz#322291 rhbz#447497 rhbz#484956 rhbz#485700 rhbz#485026 rhbz#485199 rhbz#470983 rhbz#488958 rhbz#487501 rhbz#491640 rhbz#480178 rhbz#485469 rhbz#480836 rhbz#493207 rhbz#493802 rhbz#462390 rhbz#498329 rhbz#488565 rhbz#499871