Lucene search
+L

Internet Explorer Vector Markup Language Remote Code Execution Vulnerability (2544521)

🗓️ 15 Jun 2011 00:00:00Reported by Copyright (C) 2011 Greenbone AGType 
openvas
 openvas
🔗 plugins.openvas.org👁 39 Views

Internet Explorer Vector Markup Language Remote Code Execution Vulnerability (2544521). Missing security update MS11-052. Vulnerable versions 6.x/7.x/8.x

Related
Refs
Code
# SPDX-FileCopyrightText: 2011 Greenbone AG
# Some text descriptions might be excerpted from (a) referenced
# source(s), and are Copyright (C) by the respective right holder(s).
#
# SPDX-License-Identifier: GPL-2.0-only

if(description)
{
  script_oid("1.3.6.1.4.1.25623.1.0.900290");
  script_version("2026-04-28T06:28:06+0000");
  script_tag(name:"last_modification", value:"2026-04-28 06:28:06 +0000 (Tue, 28 Apr 2026)");
  script_tag(name:"creation_date", value:"2011-06-15 15:55:00 +0200 (Wed, 15 Jun 2011)");
  script_cve_id("CVE-2011-1266");
  script_tag(name:"cvss_base", value:"9.3");
  script_tag(name:"cvss_base_vector", value:"AV:N/AC:M/Au:N/C:C/I:C/A:C");
  script_name("Internet Explorer Vector Markup Language Remote Code Execution Vulnerability (2544521)");
  script_xref(name:"URL", value:"http://support.microsoft.com/kb/2530548");
  script_xref(name:"URL", value:"http://www.securityfocus.com/bid/48173");
  script_xref(name:"URL", value:"https://docs.microsoft.com/en-us/security-updates/securitybulletins/2011/ms11-052");

  script_category(ACT_GATHER_INFO);
  script_copyright("Copyright (C) 2011 Greenbone AG");
  script_family("Windows : Microsoft Bulletins");
  script_dependencies("gb_ms_ie_detect.nasl");
  script_mandatory_keys("MS/IE/Version");
  script_require_ports(139, 445);

  script_tag(name:"impact", value:"Successful exploitation could allow remote attackers to execute arbitrary
  code in the context of the application.");

  script_tag(name:"affected", value:"Microsoft Internet Explorer version 6.x/7.x/8.x.");

  script_tag(name:"insight", value:"The flaw is caused when Internet Explorer attempts to access an object that
  has not been initialised or has been deleted causing memory corruption.");

  script_tag(name:"solution", value:"The vendor has released updates. Please see the references for more information.");

  script_tag(name:"summary", value:"This host is missing a critical security update according to
  Microsoft Bulletin MS11-052.");

  script_tag(name:"qod_type", value:"executable_version");
  script_tag(name:"solution_type", value:"VendorFix");

  exit(0);
}

include("smb_nt.inc");
include("secpod_reg.inc");
include("version_func.inc");
include("secpod_smb_func.inc");

if(hotfix_check_sp(xp:4, win2003:3, winVista:3, win2008:3, win7:2) <= 0){
  exit(0);
}

ieVer = get_kb_item("MS/IE/Version");
if(!ieVer || ieVer !~ "^[6-8]\."){
  exit(0);
}

## MS11-052 Hotfix (2544521)
if(hotfix_missing(name:"2544521") == 0){
  exit(0);
}

progDir = registry_get_sz(key:"SOFTWARE\Microsoft\Windows\CurrentVersion\",
                                                   item:"ProgramFilesDir");
if(!progDir){
  exit(0);
}

dllVer = fetch_file_version(sysPath:progDir, file_name:"Common Files\Mi" +
                                             "crosoft Shared\VGX\Vgx.dll");
if(!dllVer){
  exit(0);
}

if(hotfix_check_sp(xp:4) > 0)
{
  SP = get_kb_item("SMB/WinXP/ServicePack");
  if("Service Pack 3" >< SP)
  {
    if(version_in_range(version:dllVer, test_version:"6.0.2900.0000", test_version2:"6.0.2900.6107") ||
       version_in_range(version:dllVer, test_version:"7.0.0000.00000", test_version2:"7.0.6000.21300")||
       version_in_range(version:dllVer, test_version:"8.0.6001.00000", test_version2:"8.0.6001.23166")){
      security_message( port: 0, data: "The target host was found to be vulnerable" );
    }
    exit(0);
  }
  security_message( port: 0, data: "The target host was found to be vulnerable" );
}

else if(hotfix_check_sp(win2003:3) > 0)
{
  SP = get_kb_item("SMB/Win2003/ServicePack");
  if("Service Pack 2" >< SP)
  {
    if(version_in_range(version:dllVer, test_version:"6.0.3790.0000", test_version2:"6.0.3790.4860") ||
       version_in_range(version:dllVer, test_version:"7.0.0000.00000", test_version2:"7.0.6000.21300")||
       version_in_range(version:dllVer, test_version:"8.0.6001.00000", test_version2:"8.0.6001.23166")){
      security_message( port: 0, data: "The target host was found to be vulnerable" );
    }
    exit(0);
  }
  security_message( port: 0, data: "The target host was found to be vulnerable" );
}

else if(hotfix_check_sp(winVista:3, win2008:3) > 0)
{
  SP = get_kb_item("SMB/WinVista/ServicePack");

  if(!SP) {
    SP = get_kb_item("SMB/Win2008/ServicePack");
  }

  if("Service Pack 1" >< SP)
  {
    if(version_in_range(version:dllVer, test_version:"7.0.6001.18000", test_version2:"7.0.6001.18644")||
       version_in_range(version:dllVer, test_version:"7.0.6001.22000", test_version2:"7.0.6001.22910")||
       version_in_range(version:dllVer, test_version:"8.0.6001.19000", test_version2:"8.0.6001.19075")||
       version_in_range(version:dllVer, test_version:"8.0.6001.23000", test_version2:"8.0.6001.23168")){
      security_message( port: 0, data: "The target host was found to be vulnerable" );
    }
    exit(0);
  }

  if("Service Pack 2" >< SP)
  {
    if(version_in_range(version:dllVer, test_version:"7.0.6002.18000", test_version2:"7.0.6002.18462")||
       version_in_range(version:dllVer, test_version:"7.0.6002.22000", test_version2:"7.0.6002.22633")||
       version_in_range(version:dllVer, test_version:"8.0.6001.19000", test_version2:"8.0.6001.19075")||
       version_in_range(version:dllVer, test_version:"8.0.6001.23000", test_version2:"8.0.6001.23168")){
      security_message( port: 0, data: "The target host was found to be vulnerable" );
    }
    exit(0);
  }
  security_message( port: 0, data: "The target host was found to be vulnerable" );
}

else if(hotfix_check_sp(win7:2) > 0)
{
  if(version_in_range(version:dllVer, test_version:"8.0.7600.16000", test_version2:"8.0.7600.16805")||
     version_in_range(version:dllVer, test_version:"8.0.7600.20000", test_version2:"8.0.7600.20956")||
     version_in_range(version:dllVer, test_version:"8.0.7601.17000", test_version2:"8.0.7601.17607")||
     version_in_range(version:dllVer, test_version:"8.0.7601.21000", test_version2:"8.0.7601.21717")){
    security_message( port: 0, data: "The target host was found to be vulnerable" );
  }
}

Data

Build on a solid foundation with Vulners data

We provide the essential building blocks for cybersecurity solutions with comprehensive, structured, and constantly updated vulnerability and exploits data

Api

Power your application with Vulners API

The Vulners REST API offers reliable, high-performance access to vulnerability intelligence, with 99.9% SLA uptime and CDN-backed data delivery for seamless global access

App

Assess and manage vulnerabilities with Vulners tools

Built on top of Vulners' database and SDK, end-user solutions give security professionals and developers lightweight and powerful tools for vulnerability remediation