Lucene search
+L

Quest DR Series Appliance Default Credentials (HTTP)

🗓️ 09 Mar 2018 00:00:00Reported by Copyright (C) 2018 Greenbone AGType 
openvas
 openvas
🔗 plugins.openvas.org👁 16 Views

Quest DR Series Appliance Default Credentials Fla

Refs
Code
# SPDX-FileCopyrightText: 2018 Greenbone AG
# Some text descriptions might be excerpted from (a) referenced
# source(s), and are Copyright (C) by the respective right holder(s).
#
# SPDX-License-Identifier: GPL-2.0-only

CPE = "cpe:/a:quest:dr_appliance";

if(description)
{
  script_oid("1.3.6.1.4.1.25623.1.0.813012");
  script_version("2023-06-22T10:34:15+0000");
  script_tag(name:"cvss_base", value:"5.5");
  script_tag(name:"cvss_base_vector", value:"AV:N/AC:L/Au:S/C:P/I:N/A:P");
  script_tag(name:"last_modification", value:"2023-06-22 10:34:15 +0000 (Thu, 22 Jun 2023)");
  script_tag(name:"creation_date", value:"2018-03-09 13:07:37 +0530 (Fri, 09 Mar 2018)");
  script_tag(name:"qod_type", value:"remote_vul");
  script_name("Quest DR Series Appliance Default Credentials (HTTP)");

  script_tag(name:"summary", value:"Quest DR Series Appliances are using known default credentials
  for the HTTP login.");

  script_tag(name:"vuldetect", value:"Send crafted data via 'HTTP POST' request
  and check whether it is able to login or not.");

  script_tag(name:"insight", value:"The flaw exists because Quest DR Series
  Appliance has default credentials.");

  script_tag(name:"impact", value:"Successful exploitation will allow remote
  attacker to access the Web GUI and login directly into the DR system.");

  script_tag(name:"affected", value:"Quest DR Series Appliance.");

  script_tag(name:"solution", value:"Change the default credentials.");

  script_tag(name:"solution_type", value:"Mitigation");

  script_xref(name:"URL", value:"https://support.quest.com/dr-series/kb/220574/what-are-the-default-login-credentials-for-the-dr-");

  script_copyright("Copyright (C) 2018 Greenbone AG");
  script_category(ACT_ATTACK);
  script_family("Default Accounts");
  script_dependencies("gb_quest_dr_series_appliance_detect.nasl", "gb_default_credentials_options.nasl");
  script_mandatory_keys("quest/dr/appliance/detected");
  script_require_ports("Services/www", 443);
  script_exclude_keys("default_credentials/disable_default_account_checks");

  exit(0);
}

if(get_kb_item("default_credentials/disable_default_account_checks"))
  exit(0);

include("host_details.inc");
include("http_func.inc");
include("http_keepalive.inc");
include("misc_func.inc");

if(!port = get_app_port(cpe:CPE))
  exit(0);

if(!dir = get_app_location(cpe: CPE, port: port))
  exit(0);

if(dir == "/")
  dir = "";

url = dir + "/ws/v1.0/jsonrpc";
login_data = '{"jsonrpc":"2.0","method":"Logon","params":{"UserName":"administrator","Password":"St0r@ge!"},"id":1}';

req = http_post_put_req(port:port, url:url, data:login_data,
                        add_headers:make_array("Content-Type", "text/plain"));
buf = http_keepalive_send_recv(port:port, data:req);

if(buf =~ "^HTTP/1\.[01] 200" && '"Error: Login username or password incorrect' >!< buf &&
   '"SessionCookie' >< buf && '"userRole' >< buf && '"ServiceID' >< buf)
{
  report = 'It was possible to logging directly into the DR system with the following credentials:\n\nUsername: administrator\nPassword: St0r@ge!';
  security_message(port:port, data:report);
  exit(0);
}

exit(99);

Data

Build on a solid foundation with Vulners data

We provide the essential building blocks for cybersecurity solutions with comprehensive, structured, and constantly updated vulnerability and exploits data

Api

Power your application with Vulners API

The Vulners REST API offers reliable, high-performance access to vulnerability intelligence, with 99.9% SLA uptime and CDN-backed data delivery for seamless global access

App

Assess and manage vulnerabilities with Vulners tools

Built on top of Vulners' database and SDK, end-user solutions give security professionals and developers lightweight and powerful tools for vulnerability remediation