Lucene search

K

Adobe Acrobat 2017 Multiple Vulnerabilities (APSB18-02) - Windows

🗓️ 15 Feb 2018 00:00:00Reported by Copyright (C) 2018 Greenbone AGType 
openvas
 openvas
🔗 plugins.openvas.org👁 26 Views

Adobe Acrobat 2017 Multiple Vulnerabilities (APSB18-02) - Windows detecting Out-of-bounds read/write, Use-after-free, Heap Overflow, and Security Mitigation Bypass vulnerabilities. Allows arbitrary code execution and system control. Adobe Acrobat 2017.011.30070 and earlier affected. Upgrade to version 2017.011.30078 or late

Show more
Related
Refs
Code
# SPDX-FileCopyrightText: 2018 Greenbone AG
# Some text descriptions might be excerpted from (a) referenced
# source(s), and are Copyright (C) by the respective right holder(s).
#
# SPDX-License-Identifier: GPL-2.0-only

CPE = "cpe:/a:adobe:acrobat";

if(description)
{
  script_oid("1.3.6.1.4.1.25623.1.0.812926");
  script_version("2024-02-12T14:37:47+0000");
  script_cve_id("CVE-2018-4872", "CVE-2018-4890", "CVE-2018-4904", "CVE-2018-4910",
                "CVE-2018-4917", "CVE-2018-4888", "CVE-2018-4892", "CVE-2018-4902",
                "CVE-2018-4911", "CVE-2018-4913", "CVE-2018-4879", "CVE-2018-4895",
                "CVE-2018-4898", "CVE-2018-4901", "CVE-2018-4915", "CVE-2018-4916",
                "CVE-2018-4918", "CVE-2018-4880", "CVE-2018-4881", "CVE-2018-4882",
                "CVE-2018-4883", "CVE-2018-4884", "CVE-2018-4885", "CVE-2018-4886",
                "CVE-2018-4887", "CVE-2018-4889", "CVE-2018-4891", "CVE-2018-4893",
                "CVE-2018-4894", "CVE-2018-4896", "CVE-2018-4897", "CVE-2018-4899",
                "CVE-2018-4900", "CVE-2018-4903", "CVE-2018-4905", "CVE-2018-4906",
                "CVE-2018-4907", "CVE-2018-4908", "CVE-2018-4909", "CVE-2018-4912",
                "CVE-2018-4914", "CVE-2018-4997", "CVE-2018-4998", "CVE-2018-4999");
  script_tag(name:"cvss_base", value:"10.0");
  script_tag(name:"cvss_base_vector", value:"AV:N/AC:L/Au:N/C:C/I:C/A:C");
  script_tag(name:"last_modification", value:"2024-02-12 14:37:47 +0000 (Mon, 12 Feb 2024)");
  script_tag(name:"severity_vector", value:"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H");
  script_tag(name:"severity_origin", value:"NVD");
  script_tag(name:"severity_date", value:"2020-08-24 17:37:00 +0000 (Mon, 24 Aug 2020)");
  script_tag(name:"creation_date", value:"2018-02-15 13:54:40 +0530 (Thu, 15 Feb 2018)");
  script_name("Adobe Acrobat 2017 Multiple Vulnerabilities (APSB18-02) - Windows");

  script_tag(name:"summary", value:"Adobe Acrobat 2017 is prone to multiple vulnerabilities.");

  script_tag(name:"vuldetect", value:"Checks if a vulnerable version is present on the target host.");

  script_tag(name:"insight", value:"Multiple flaws exist due to:

  - Multiple Out-of-bounds read errors.

  - Multiple Out-of-bounds write errors.

  - Multiple Use-after-free errors.

  - Multiple Heap Overflow errors.

  - A memory corruption error.

  - A Security Mitigation Bypass error.");

  script_tag(name:"impact", value:"Successful exploitation will allow an
  attacker to gain escalated privileges, execute arbitrary code on affected
  system and take control of the affected system.");

  script_tag(name:"affected", value:"Adobe Acrobat 2017.011.30070 and earlier
  versions on Windows.");

  script_tag(name:"solution", value:"Upgrade to Adobe Acrobat 2017 version
  2017.011.30078 or later.");

  script_tag(name:"solution_type", value:"VendorFix");
  script_tag(name:"qod_type", value:"registry");
  script_xref(name:"URL", value:"https://helpx.adobe.com/security/products/acrobat/apsb18-02.html");
  script_category(ACT_GATHER_INFO);
  script_copyright("Copyright (C) 2018 Greenbone AG");
  script_family("General");
  script_dependencies("secpod_adobe_prdts_detect_win.nasl");
  script_mandatory_keys("Adobe/Acrobat/Win/Ver");
  exit(0);
}

include("host_details.inc");
include("version_func.inc");

if(!infos = get_app_version_and_location(cpe:CPE, exit_no_version:TRUE))
  exit(0);

vers = infos['version'];
path = infos['location'];

##2017.011.30078 == 17.011.30078
if(version_in_range(version:vers, test_version:"17.0", test_version2:"17.011.30077")) {
  report = report_fixed_ver(installed_version:vers, fixed_version:"17.011.30078 (2017.011.30078)", install_path:path);
  security_message(data:report);
  exit(0);
}

exit(99);