Lucene search

K
openvasCopyright (C) 2023 Greenbone AGOPENVAS:1361412562310170619
HistoryFeb 24, 2023 - 12:00 a.m.

D-Link Multiple DIR Devices RCE Vulnerability (Sep 2019)

2023-02-2400:00:00
Copyright (C) 2023 Greenbone AG
plugins.openvas.org
1

9.8 High

CVSS3

Attack Vector

NETWORK

Attack Complexity

LOW

Privileges Required

NONE

User Interaction

NONE

Scope

UNCHANGED

Confidentiality Impact

HIGH

Integrity Impact

HIGH

Availability Impact

HIGH

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

9.6 High

AI Score

Confidence

High

10 High

CVSS2

Access Vector

NETWORK

Access Complexity

LOW

Authentication

NONE

Confidentiality Impact

COMPLETE

Integrity Impact

COMPLETE

Availability Impact

COMPLETE

AV:N/AC:L/Au:N/C:C/I:C/A:C

0.963 High

EPSS

Percentile

99.5%

Multiple D-Link DIR devices are prone to a remote command
execution (RCE) vulnerability.

# SPDX-FileCopyrightText: 2023 Greenbone AG
# Some text descriptions might be excerpted from (a) referenced
# source(s), and are Copyright (C) by the respective right holder(s).
#
# SPDX-License-Identifier: GPL-2.0-only

if(description)
{
  script_oid("1.3.6.1.4.1.25623.1.0.170619");
  script_version("2023-11-21T05:05:52+0000");
  script_tag(name:"last_modification", value:"2023-11-21 05:05:52 +0000 (Tue, 21 Nov 2023)");
  script_tag(name:"creation_date", value:"2023-02-24 21:18:49 +0000 (Fri, 24 Feb 2023)");
  script_tag(name:"cvss_base", value:"10.0");
  script_tag(name:"cvss_base_vector", value:"AV:N/AC:L/Au:N/C:C/I:C/A:C");
  script_tag(name:"severity_vector", value:"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H");
  script_tag(name:"severity_origin", value:"NVD");
  script_tag(name:"severity_date", value:"2019-10-10 21:15:00 +0000 (Thu, 10 Oct 2019)");

  script_tag(name:"qod_type", value:"remote_banner");

  script_tag(name:"solution_type", value:"WillNotFix");

  script_cve_id("CVE-2019-16920");

  script_name("D-Link Multiple DIR Devices RCE Vulnerability (Sep 2019)");

  script_category(ACT_GATHER_INFO);

  script_copyright("Copyright (C) 2023 Greenbone AG");
  script_family("Web application abuses");
  script_dependencies("gb_dlink_dir_consolidation.nasl");
  script_mandatory_keys("d-link/dir/detected");

  script_tag(name:"summary", value:"Multiple D-Link DIR devices are prone to a remote command
  execution (RCE) vulnerability.");

  script_tag(name:"vuldetect", value:"Checks if a vulnerable version is present on the target host.");

  script_tag(name:"insight", value:"Any arguments after a newline character sent as ping_ipaddr in a
  POST to /apply_sec.cgi are executed on the device with root privileges.");

  script_tag(name:"affected", value:"D-Link DIR-615, DIR-652, DIR-655, DIR-825, DIR-835, DIR-855L,
  DIR-862L and DIR-866L devices.");

  script_tag(name:"solution", value:"No solution was made available by the vendor. General solution
  options are to upgrade to a newer release, disable respective features, remove the product or
  replace the product by another one.

  Note: CISA states that the impacted devices are end-of-life and should be disconnected if still
  in use.");

  script_xref(name:"URL", value:"https://www.kb.cert.org/vuls/id/766427");
  script_xref(name:"URL", value:"https://www.fortiguard.com/zeroday/FG-VD-19-117");
  script_xref(name:"URL", value:"https://www.seebug.org/vuldb/ssvid-98079");
  script_xref(name:"URL", value:"https://80vul.medium.com/determine-the-device-model-affected-by-cve-2019-16920-by-zoomeye-bf6fec7f9bb3");
  script_xref(name:"URL", value:"https://www.cisa.gov/known-exploited-vulnerabilities-catalog");
  script_xref(name:"CISA", value:"Known Exploited Vulnerability (KEV) catalog");

  exit(0);
}

include("host_details.inc");
include("version_func.inc");

cpe_list = make_list( "cpe:/o:dlink:dir-615_firmware",
                      "cpe:/o:dlink:dir-652_firmware",
                      "cpe:/o:dlink:dir-655_firmware",
                      "cpe:/o:dlink:dir-825_firmware",
                      "cpe:/o:dlink:dir-835_firmware",
                      "cpe:/o:dlink:dir-855l_firmware",
                      "cpe:/o:dlink:dir-862l_firmware",
                      "cpe:/o:dlink:dir-866l_firmware" );

if ( ! infos = get_app_port_from_list( cpe_list:cpe_list ) )
  exit( 0 );

cpe = infos["cpe"];
port = infos["port"];

if ( ! version = get_app_version( cpe:cpe, nofork:TRUE ) )
  exit( 0 );

# nb: For DIR-655, only revision C seems to be affected
if ( cpe =~ "dir-655" ) {
  if ( ! hw_vers = get_kb_item( "d-link/dir/hw_version" ) )
    exit( 0 );

  if ( hw_vers !~ "^C" )
    exit( 99 );
}

report = report_fixed_ver( installed_version:version, fixed_version:"None" );
security_message( port:port, data:report );
exit( 0 );

9.8 High

CVSS3

Attack Vector

NETWORK

Attack Complexity

LOW

Privileges Required

NONE

User Interaction

NONE

Scope

UNCHANGED

Confidentiality Impact

HIGH

Integrity Impact

HIGH

Availability Impact

HIGH

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

9.6 High

AI Score

Confidence

High

10 High

CVSS2

Access Vector

NETWORK

Access Complexity

LOW

Authentication

NONE

Confidentiality Impact

COMPLETE

Integrity Impact

COMPLETE

Availability Impact

COMPLETE

AV:N/AC:L/Au:N/C:C/I:C/A:C

0.963 High

EPSS

Percentile

99.5%