WAGO PLC Detection (OPC UA)
🗓️ 04 Mar 2019 00:00:00Reported by Copyright (C) 2019 Greenbone AGType
openvas🔗 plugins.openvas.org👁 89 Views
# SPDX-FileCopyrightText: 2019 Greenbone AG
# Some text descriptions might be excerpted from (a) referenced
# source(s), and are Copyright (C) by the respective right holder(s).
#
# SPDX-License-Identifier: GPL-2.0-only
if (description)
{
script_oid("1.3.6.1.4.1.25623.1.0.142065");
script_version("2023-08-08T05:06:11+0000");
script_tag(name:"last_modification", value:"2023-08-08 05:06:11 +0000 (Tue, 08 Aug 2023)");
script_tag(name:"creation_date", value:"2019-03-04 12:13:39 +0700 (Mon, 04 Mar 2019)");
script_tag(name:"cvss_base", value:"0.0");
script_tag(name:"cvss_base_vector", value:"AV:N/AC:L/Au:N/C:N/I:N/A:N");
script_tag(name:"qod_type", value:"remote_banner");
script_name("WAGO PLC Detection (OPC UA)");
script_tag(name:"summary", value:"OPC UA based detection of WAGO PLC Controllers.");
script_category(ACT_GATHER_INFO);
script_copyright("Copyright (C) 2019 Greenbone AG");
script_family("Product detection");
script_dependencies("gb_opc_ua_tcp_detect.nasl");
# nb: No script_require_ports() as this will support both, TCP and UDP in the future.
script_mandatory_keys("opcua/detected");
exit(0);
}
include("port_service_func.inc");
if (!proto = get_kb_item("opcua/proto"))
exit(0);
port = service_get_port(default: 4840, proto: "opc-ua", ipproto: proto);
prod_name = get_kb_item("opcua/" + port + "/" + proto + "/product_name");
if (!prod_name || prod_name !~ "^WAGO ")
exit(0);
model = "unknown";
set_kb_item(name: "wago_plc/detected", value: TRUE);
set_kb_item(name: "wago_plc/opcua/detected", value: TRUE);
set_kb_item(name: "wago_plc/opcua/" + port + "/" + proto + "/detected", value: TRUE);
set_kb_item(name: "wago_plc/opcua/port", value: port);
set_kb_item(name: "wago_plc/opcua/" + proto + "/port", value: port);
set_kb_item(name: "wago_plc/opcua/" + port + "/proto", value: proto);
# WAGO OPC UA Server
# WAGO 750-8207 PFC200 2ETH RS 3G
# WAGO 750-8102 PFC100 2ETH RS
mod = eregmatch(pattern: "WAGO (.+)", string: prod_name, icase: FALSE);
if (!isnull(mod[1]))
model = mod[1];
set_kb_item(name: "wago_plc/opcua/" + port + "/" + proto + "/model", value: model);
# 1.3.1
# 3.5.14.30
# 3.5.15.40
# 3.5.13.20
# nb: This is the version of the OPC UA Server and not the Firmware version of the PLC so we're
# not registering this in the "/fw_version" KB key.
if (version = get_kb_item("opcua/" + port + "/" + proto + "/version"))
set_kb_item(name: "wago_plc/opcua/" + port + "/" + proto + "/opc_version", value: version);
if (build = get_kb_item("opcua/" + port + "/" + proto + "/build"))
set_kb_item(name: "wago_plc/opcua/" + port + "/" + proto + "/build", value: build);
exit(0);
Data
Build on a solid foundation with Vulners data
We provide the essential building blocks for cybersecurity solutions with comprehensive, structured, and constantly updated vulnerability and exploits data
Api
Power your application with Vulners API
The Vulners REST API offers reliable, high-performance access to vulnerability intelligence, with 99.9% SLA uptime and CDN-backed data delivery for seamless global access
App
Assess and manage vulnerabilities with Vulners tools
Built on top of Vulners' database and SDK, end-user solutions give security professionals and developers lightweight and powerful tools for vulnerability remediation
08 Aug 2023 00:00Current
7.1High risk