Rockwell Automation PowerMonitor Detection (HTTP)

🗓️ 20 Feb 2019 00:00:00Reported by Copyright (C) 2019 Greenbone AGType 
openvas
 openvas
🔗 plugins.openvas.org👁 81 Views

Rockwell Automation PowerMonitor HTTP detection script

Refs
Code
# SPDX-FileCopyrightText: 2019 Greenbone AG
# Some text descriptions might be excerpted from (a) referenced
# source(s), and are Copyright (C) by the respective right holder(s).
#
# SPDX-License-Identifier: GPL-2.0-only

if(description)
{
  script_oid("1.3.6.1.4.1.25623.1.0.142010");
  script_version("2024-12-24T05:05:31+0000");
  script_tag(name:"last_modification", value:"2024-12-24 05:05:31 +0000 (Tue, 24 Dec 2024)");
  script_tag(name:"creation_date", value:"2019-02-20 16:34:48 +0700 (Wed, 20 Feb 2019)");
  script_tag(name:"cvss_base", value:"0.0");
  script_tag(name:"cvss_base_vector", value:"AV:N/AC:L/Au:N/C:N/I:N/A:N");

  script_tag(name:"qod_type", value:"remote_banner");

  script_name("Rockwell Automation PowerMonitor Detection (HTTP)");

  script_category(ACT_GATHER_INFO);

  script_copyright("Copyright (C) 2019 Greenbone AG");
  script_family("Product detection");
  script_dependencies("find_service.nasl", "httpver.nasl", "global_settings.nasl");
  script_require_ports("Services/www", 80);
  script_exclude_keys("Settings/disable_cgi_scanning");

  script_tag(name:"summary", value:"HTTP based detection of Rockwell Automation PowerMonitor
  devices.");

  script_xref(name:"URL", value:"https://ab.rockwellautomation.com/Energy-Monitoring/");

  exit(0);
}

include("cpe.inc");
include("host_details.inc");
include("http_func.inc");
include("http_keepalive.inc");
include("os_func.inc");
include("port_service_func.inc");

port = http_get_port(default: 80);

url = "/overview.shtm";

res = http_get_cache(port: port, item: url);

if ("Rockwell Automation" >!< res || "<title>PowerMonitor" >!< res) {
  url = "/body.htm";

  res = http_get_cache(port: port, item: url);

  if (">Powermonitor" >!< res || ">Catalog Number:<" >!< res)
    exit(0);
}

version = "unknown";
location = "/";
conclUrl = http_report_vuln_url(port: port, url: url, url_only: TRUE);

mod = eregmatch(pattern: ">Powermonitor ([0-9]+)", string: res);
if (!isnull(mod[1])) {
  model = mod[1];
} else {
  url = "/";

  res2 = http_get_cache(port: port, item: url);

  mod = eregmatch(pattern: "<title>Powermonitor ([0-9]+)", string: res2, icase: TRUE);
  if (!isnull(mod[1])) {
    model = mod[1];
    conclUrl += '\n' + http_report_vuln_url(port: port, url: url, url_only: TRUE);
  }
}

# "Firmware_Revision">Revision 4.10
vers = eregmatch(pattern: '"Firmware_Revision">Revision ([0-9.]+)', string: res);
if (!isnull(vers[1]))
  version = vers[1];
else {
  # <td>Operating System Version</td>
  # <td><div id = "OS">411</div></td>
  vers = eregmatch(pattern: '"OS">([0-9]+)', string: res);
  if (!isnull(vers[1])) {
    version = vers[1];
  } else {
    # <td><b>Operating System Version:</b></td><td>330</td></tr><tr>
    vers = eregmatch(pattern: ">Operating System Version:[^>]+>[^>]+>[^>]+>([0-9]+)<", string: res);
    if (!isnull(vers[1]))
      version = vers[1];
  }
}

# <td><div id = "Catalog">1408-EM3A-ENT B</div></td>
prod = eregmatch(pattern: '"Catalog">([^<]+)<', string: res);
if (isnull(prod[1]))
  # <td><b>Catalog Number:</b></td><td>1408-EM3A-ENTA</td></tr><tr>
  prod = eregmatch(pattern: "Catalog Number:[^>]+>[^>]+>[^>]+>([^<]+)<", string: res);

if (!isnull(prod[1])) {
  set_kb_item(name: "rockwellautomation/powermonitor/catalog_number", value: prod[1]);
  extra = "Catalog Number: " + prod[1] + '\n';
}

# "Ethernet_Address">F4:54:33:54:C0:E1
mac = eregmatch(pattern: '"Ethernet_Address">([A-F0-9:]{17})', string: res);
if (!isnull(mac[1])) {
  register_host_detail(name: "MAC", value: mac[1], desc: "gb_rockwell_powermonitor_http_detect.nasl");
  replace_kb_item(name: "Host/mac_address", value: mac[1]);
  extra += "Mac Address:   " + mac[1] + '\n';
}

set_kb_item(name: "rockwellautomation/powermonitor/detected", value: TRUE);
set_kb_item(name: "rockwellautomation/powermonitor/http/detected", value: TRUE);

if (model) {
  app_cpe = build_cpe(value: version, exp: "^([0-9.]+)",
                      base: "cpe:/a:rockwellautomation:powermonitor" + model + ":");
  os_cpe = build_cpe(value: version, exp: "^([0-9.]+)",
                     base: "cpe:/o:rockwellautomation:powermonitor" + model + ":");
  hw_cpe = "cpe:/h:rockwellautomation:powermeter" + model;
} else {
  app_cpe = build_cpe(value: version, exp: "^([0-9.]+)",
                      base: "cpe:/a:rockwellautomation:powermonitor:");
  os_cpe = build_cpe(value: version, exp: "^([0-9.]+)",
                     base: "cpe:/o:rockwellautomation:powermonitor:");
  hw_cpe = "cpe:/h:rockwellautomation:powermeter";
}

os_register_and_report(os: "Rockwell Automation PowerMonitor Firmware", cpe: os_cpe,
                       desc: "Rockwell Automation PowerMonitor Detection (HTTP)", runs_key: "unixoide");

register_product(cpe: hw_cpe, location: "/", port: port, service: "www");
register_product(cpe: os_cpe, location: "/", port: port, service: "www");
register_product(cpe: app_cpe, location: "/", port: port, service: "www");

log_message(data: build_detection_report(app: "Rockwell Automation PowerMonitor " + model, version: version,
                                         install: "/", cpe: app_cpe, concluded: vers[0],
                                         concludedUrl: conclUrl, extra: chomp(extra)),
            port: port);

exit(0);

Data

Build on a solid foundation with Vulners data

We provide the essential building blocks for cybersecurity solutions with comprehensive, structured, and constantly updated vulnerability and exploits data

Api

Power your application with Vulners API

The Vulners REST API offers reliable, high-performance access to vulnerability intelligence, with 99.9% SLA uptime and CDN-backed data delivery for seamless global access

App

Assess and manage vulnerabilities with Vulners tools

Built on top of Vulners' database and SDK, end-user solutions give security professionals and developers lightweight and powerful tools for vulnerability remediation