WAGO PLC Detection Consolidation
🗓️ 07 Dec 2018 00:00:00Reported by Copyright (C) 2018 Greenbone AGType
openvas🔗 plugins.openvas.org👁 35 Views
| Source | Link |
|---|---|
| wago | www.wago.com/global/c/plcs-%E2%80%93-controllers |
# SPDX-FileCopyrightText: 2018 Greenbone AG
# Some text descriptions might be excerpted from (a) referenced
# source(s), and are Copyright (C) by the respective right holder(s).
#
# SPDX-License-Identifier: GPL-2.0-only
if(description)
{
script_oid("1.3.6.1.4.1.25623.1.0.141766");
script_version("2023-08-08T05:06:11+0000");
script_tag(name:"last_modification", value:"2023-08-08 05:06:11 +0000 (Tue, 08 Aug 2023)");
script_tag(name:"creation_date", value:"2018-12-07 12:20:20 +0700 (Fri, 07 Dec 2018)");
script_tag(name:"cvss_base", value:"0.0");
script_tag(name:"cvss_base_vector", value:"AV:N/AC:L/Au:N/C:N/I:N/A:N");
script_tag(name:"qod_type", value:"remote_banner");
script_name("WAGO PLC Detection Consolidation");
script_tag(name:"summary", value:"Consolidation of WAGO PLC Controller detections.");
script_category(ACT_GATHER_INFO);
script_copyright("Copyright (C) 2018 Greenbone AG");
script_family("Product detection");
script_dependencies("gb_wago_plc_http_detect.nasl", "gb_wago_plc_snmp_detect.nasl",
"gb_wago_plc_ethernetip_detect.nasl", "gb_wago_plc_opcua_detect.nasl");
script_mandatory_keys("wago_plc/detected");
script_xref(name:"URL", value:"https://www.wago.com/global/c/plcs-%E2%80%93-controllers");
exit(0);
}
include("host_details.inc");
include("os_func.inc");
include("version_func.inc");
if (!get_kb_item("wago_plc/detected"))
exit(0);
detected_model = "unknown";
detected_fw_version = "unknown";
foreach source (make_list("http", "ethernetip", "opcua", "snmp")) {
fw_version_list = get_kb_list("wago_plc/" + source + "/*/fw_version");
foreach fw_version (fw_version_list) {
if (fw_version && fw_version != "unknown") {
if (detected_fw_version == "unknown") {
detected_fw_version = fw_version;
set_kb_item(name: "wago_plc/fw_version", value: fw_version);
}
# e.g. EtherNet/IP version is less accurate than HTTP
else if (version_is_greater(version: fw_version, test_version: detected_fw_version)) {
detected_fw_version = fw_version;
set_kb_item(name: "wago_plc/fw_version", value: fw_version);
}
}
}
model_list= get_kb_list("wago_plc/" + source + "/*/model");
foreach model (model_list) {
if (model && model != "unknown") {
detected_model = model;
set_kb_item(name: "wago_plc/model", value: model);
break;
}
}
}
app_name = "WAGO PLC Controller ";
if (detected_model != "unknown") {
app_name += detected_model;
mod = eregmatch(pattern: "([0-9]+-[0-9]+)", string: detected_model);
if (!isnull(mod[1])) {
app_cpe = "cpe:/a:wago:" + mod[1];
os_cpe = "cpe:/o:wago:" + mod[1] + "_firmware";
hw_cpe = "cpe:/h:wago:" + mod[1];
} else {
app_cpe = "cpe:/a:wago:plc";
os_cpe = "cpe:/o:wago:plc_firmware";
hw_cpe = "cpe:/h:wago:plc";
}
}
else {
app_cpe = "cpe:/a:wago:plc";
os_cpe = "cpe:/o:wago:plc_firmware";
hw_cpe = "cpe:/h:wago:plc";
}
if (detected_fw_version != "unknown") {
app_cpe += ":" + detected_fw_version;
os_cpe += ":" + detected_fw_version;
}
os_register_and_report(os: "WAGO PLC Controller Firmware", cpe: os_cpe, desc: "WAGO PLC Detection Consolidation",
runs_key: "unixoide");
location = "/";
if (http_ports = get_kb_list("wago_plc/http/port")) {
foreach port (http_ports) {
concluded = get_kb_item("wago_plc/http/" + port + "/concluded");
concUrl = get_kb_item("wago_plc/http/" + port + "/concUrl");
mac = get_kb_item("wago_plc/http/" + port + "/mac");
if (mac)
macaddr = "MAC address: " + mac;
extra += "HTTP(s) on port " + port + '/tcp\n';
if (concluded)
extra += " Concluded from version/product identification result: " + concluded + '\n';
if (concUrl)
extra += " Concluded from version/product identification location: " + concUrl + '\n';
register_product(cpe: hw_cpe, location: location, port: port, service: "www");
register_product(cpe: os_cpe, location: location, port: port, service: "www");
register_product(cpe: app_cpe, location: location, port: port, service: "www");
}
}
if (ether_ports = get_kb_list("wago_plc/ethernetip/port")) {
foreach port (ether_ports) {
if (ether_protos = get_kb_list("wago_plc/ethernetip/" + port + "/proto")) {
foreach proto (ether_protos) {
extra += "EtherNet/IP on port " + port + "/" + proto + '\n';
register_product(cpe: hw_cpe, location: location, port: port, service: "ethernetip", proto: proto);
register_product(cpe: os_cpe, location: location, port: port, service: "ethernetip", proto: proto);
register_product(cpe: app_cpe, location: location, port: port, service: "ethernetip", proto: proto);
}
}
}
}
if (opcua_ports = get_kb_list("wago_plc/opcua/port")) {
foreach port (opcua_ports) {
if (opcua_protos = get_kb_list("wago_plc/opcua/" + port + "/proto")) {
foreach proto (opcua_protos) {
extra += "OPC UA on port " + port + "/" + proto + '\n';
if (model = get_kb_item("wago_plc/opcua/" + port + "/" + proto + "/model"))
extra += " OPC UA Model: " + model + '\n';
if (opc_version = get_kb_item("wago_plc/opcua/" + port + "/" + proto + "/opc_version")) {
extra += " OPC UA Version: " + opc_version + '\n';
opc_cpe = "cpe:/a:wago:opcua_server:" + opc_version;
}
else
opc_cpe = "cpe:/a:wago:opcua_server";
if (build = get_kb_item("wago_plc/opcua/" + port + "/" + proto + "/build"))
extra += " OPC UA Build: " + build + '\n';
register_product(cpe:hw_cpe, location: location, port: port, service: "opc-ua", proto: proto);
register_product(cpe:os_cpe, location: location, port: port, service: "opc-ua", proto: proto);
# nb:
# - The OPC UA version seems to be not the actual firmware version
# - For OPC UA we're registering a different app CPE here
register_product(cpe:opc_cpe, location: location, port: port, service: "opc-ua", proto: proto);
}
}
}
}
if (snmp_ports = get_kb_list("wago_plc/snmp/port")) {
foreach port (snmp_ports) {
extra += "SNMP on port " + port + '/udp\n';
concluded = get_kb_item("wago_plc/snmp/" + port + "/concluded");
if (concluded)
extra += " Concluded from SNMP sysDescr OID: " + concluded + '\n';
concludedfw = get_kb_item("wago_plc/snmp/" + port + "/concludedfw");
if (concludedfw)
extra += " " + concludedfw + '\n';
register_product(cpe: app_cpe, location: port + "/udp", port: port, service: "snmp", proto: "udp");
register_product(cpe: os_cpe, location: port + "/udp", port: port, service: "snmp", proto: "udp");
register_product(cpe: hw_cpe, location: port + "/udp", port: port, service: "snmp", proto: "udp");
}
}
report += build_detection_report(app: app_name + " Firmware", version: detected_fw_version,
install: location, cpe: os_cpe);
report += '\n\n';
report += build_detection_report(app: app_name, version: detected_fw_version,
install: location, cpe: app_cpe);
report += '\n\n';
report += build_detection_report(app: app_name, install: location, cpe: hw_cpe, skip_version: TRUE, extra: macaddr);
if (opc_cpe) {
report += '\n\n';
report += build_detection_report(app: "WAGO OPC UA Server", install: location, cpe: opc_cpe, version: opc_version);
}
if (extra) {
report += '\n\nDetection methods:\n';
report += '\n' + extra;
}
log_message(port: 0, data: chomp(report));
exit(0);
Data
Build on a solid foundation with Vulners data
We provide the essential building blocks for cybersecurity solutions with comprehensive, structured, and constantly updated vulnerability and exploits data
Api
Power your application with Vulners API
The Vulners REST API offers reliable, high-performance access to vulnerability intelligence, with 99.9% SLA uptime and CDN-backed data delivery for seamless global access
App
Assess and manage vulnerabilities with Vulners tools
Built on top of Vulners' database and SDK, end-user solutions give security professionals and developers lightweight and powerful tools for vulnerability remediation
08 Aug 2023 00:00Current
7.1High risk
Vulners AI Score7.1