Lucene search
+L

Cisco Energy Management Suite Detection

🗓️ 08 Nov 2018 00:00:00Reported by Copyright (C) 2018 Greenbone AGType 
openvas
 openvas
🔗 plugins.openvas.org👁 43 Views

Detection of Cisco Energy Management Suite. The script sends a connection request to the server and attempts to detect Cisco Energy Management Suite and to extract its version

Refs
Code
# SPDX-FileCopyrightText: 2018 Greenbone AG
# Some text descriptions might be excerpted from (a) referenced
# source(s), and are Copyright (C) by the respective right holder(s).
#
# SPDX-License-Identifier: GPL-2.0-only

if(description)
{
  script_oid("1.3.6.1.4.1.25623.1.0.141665");
  script_version("2023-07-26T05:05:09+0000");
  script_tag(name:"last_modification", value:"2023-07-26 05:05:09 +0000 (Wed, 26 Jul 2023)");
  script_tag(name:"creation_date", value:"2018-11-08 11:41:07 +0700 (Thu, 08 Nov 2018)");
  script_tag(name:"cvss_base", value:"0.0");
  script_tag(name:"cvss_base_vector", value:"AV:N/AC:L/Au:N/C:N/I:N/A:N");

  script_tag(name:"qod_type", value:"remote_banner");

  script_name("Cisco Energy Management Suite Detection");

  script_tag(name:"summary", value:"Detection of Cisco Energy Management Suite.

The script sends a connection request to the server and attempts to detect Cisco Energy Management Suite and to
extract its version.");

  script_category(ACT_GATHER_INFO);

  script_copyright("Copyright (C) 2018 Greenbone AG");
  script_family("Product detection");
  script_dependencies("find_service.nasl", "httpver.nasl", "global_settings.nasl");
  script_require_ports("Services/www", 443);
  script_exclude_keys("Settings/disable_cgi_scanning");

  script_xref(name:"URL", value:"https://www.cisco.com/c/en_ca/products/switches/energy-management-technology/index.html");

  exit(0);
}

include("cpe.inc");
include("host_details.inc");
include("http_func.inc");
include("http_keepalive.inc");
include("port_service_func.inc");

port = http_get_port(default: 443);

res = http_get_cache(port: port, item: "/");

if ("<title>Cisco Energy Management</title>" >< res && "var JEM_FLAVOR" >< res) {
  version = "unknown";

  # var JEM_VERSION="5.2.0.47736";
  vers = eregmatch(pattern: 'JEM_VERSION="([0-9.]+)', string: res);
  if (!isnull(vers[1]))
    version = vers[1];

  set_kb_item(name: "cisco_energy_management/detected", value: TRUE);

  cpe = build_cpe(value: version, exp: "^([0-9.]+)", base: "cpe:/a:cisco:energy_management:");
  if (!cpe)
    cpe = 'cpe:/a:cisco:energy_management';

  register_product(cpe: cpe, location: "/", port: port, service: "www");

  log_message(data: build_detection_report(app: "Cisco Energy Management Suite", version: version, install: "/",
                                           cpe: cpe, concluded: vers[0]),
              port: port);
  exit(0);
}

exit(0);

Data

Build on a solid foundation with Vulners data

We provide the essential building blocks for cybersecurity solutions with comprehensive, structured, and constantly updated vulnerability and exploits data

Api

Power your application with Vulners API

The Vulners REST API offers reliable, high-performance access to vulnerability intelligence, with 99.9% SLA uptime and CDN-backed data delivery for seamless global access

App

Assess and manage vulnerabilities with Vulners tools

Built on top of Vulners' database and SDK, end-user solutions give security professionals and developers lightweight and powerful tools for vulnerability remediation