Code
# SPDX-FileCopyrightText: 2018 Greenbone AG
# Some text descriptions might be excerpted from (a) referenced
# source(s), and are Copyright (C) by the respective right holder(s).
#
# SPDX-License-Identifier: GPL-2.0-only

if (description)
{
  script_oid("1.3.6.1.4.1.25623.1.0.141392");
  script_version("2023-08-10T05:05:53+0000");
  script_tag(name:"last_modification", value:"2023-08-10 05:05:53 +0000 (Thu, 10 Aug 2023)");
  script_tag(name:"creation_date", value:"2018-08-23 16:34:16 +0700 (Thu, 23 Aug 2018)");
  script_tag(name:"cvss_base", value:"0.0");
  script_tag(name:"cvss_base_vector", value:"AV:N/AC:L/Au:N/C:N/I:N/A:N");

  script_tag(name:"qod_type", value:"remote_banner");

  script_name("Crestron AirMedia Presentation Gateway Detection (SNMP)");

  script_tag(name:"summary", value:"SNMP based detection of Crestron AirMedia Presentation Gateway
  devices.");

  script_category(ACT_GATHER_INFO);

  script_copyright("Copyright (C) 2018 Greenbone AG");
  script_family("Product detection");
  script_dependencies("gb_snmp_info_collect.nasl");
  script_require_udp_ports("Services/udp/snmp", 161);
  script_mandatory_keys("SNMP/sysdescr/available");

  exit(0);
}

include("snmp_func.inc");

port = snmp_get_port(default: 161);

if (!sysdesc = snmp_get_sysdescr(port: port))
  exit(0);

if ("Crestron Electronics AM-" >!< sysdesc)
  exit(0);

version = "unknown";
model = "unknown";

# Crestron Electronics AM-100 (Version 1.1.0.14)
# Crestron Electronics AM-100 (Version 1.4.0.13)
# nb: The following is a AM-101 device (see consolidation for special handling)
# Crestron Electronics AM-100 (Version 2.8.0.32)
mod = eregmatch(pattern: "Crestron Electronics (AM\-[0-9]+)", string: sysdesc);
if (!isnull(mod[1]))
  model = mod[1];

vers = eregmatch(pattern: "Version ([0-9.]+)", string: sysdesc);
if (!isnull(vers[1]))
  version = vers[1];

set_kb_item(name: "crestron_airmedia/detected", value: TRUE);
set_kb_item(name: "crestron_airmedia/snmp/detected", value: TRUE);
set_kb_item(name: "crestron_airmedia/snmp/port", value: port);
set_kb_item(name: "crestron_airmedia/snmp/" + port + "/model", value: model);
set_kb_item(name: "crestron_airmedia/snmp/" + port + "/fw_version", value: version);
set_kb_item(name: "crestron_airmedia/snmp/" + port + "/concluded", value: sysdesc);

exit(0);

Data

Build on a solid foundation with Vulners data

We provide the essential building blocks for cybersecurity solutions with comprehensive, structured, and constantly updated vulnerability and exploits data

Api

Power your application with Vulners API

The Vulners REST API offers reliable, high-performance access to vulnerability intelligence, with 99.9% SLA uptime and CDN-backed data delivery for seamless global access

App

Assess and manage vulnerabilities with Vulners tools

Built on top of Vulners' database and SDK, end-user solutions give security professionals and developers lightweight and powerful tools for vulnerability remediation

10 Aug 2023 00:00Current
7.1High risk
Vulners AI Score7.1
46