Cisco Nexus 5000 Series Switches Telnet CLI Command Injection Vulnerability (cisco-sa-20170517-nss1)
🗓️ 18 May 2017 00:00:00Reported by Copyright (C) 2017 Greenbone Networks GmbHType
openvas🔗 plugins.openvas.org👁 39 Views
| Reporter | Title | Published | Views | Family All 9 |
|---|---|---|---|---|
| Cisco Nexus Series Switches Telnet CLI Command Injection Vulnerability | 17 May 201716:00 | – | cisco | |
| Cisco Nexus 5000 Series Switches NX-OS System Software Command Injection Vulnerability (CNVD-2017-07542) | 23 May 201700:00 | – | cnvd | |
| CVE-2017-6650 | 22 May 201701:00 | – | cve | |
| CVE-2017-6650 | 22 May 201701:00 | – | cvelist | |
| EUVD-2017-15704 | 7 Oct 202500:30 | – | euvd | |
| CVE-2017-6650 | 22 May 201701:29 | – | nvd | |
| CVE-2017-6650 | 22 May 201701:29 | – | osv | |
| Command injection | 22 May 201701:29 | – | prion | |
| Cisco Nexus Series Switches Telnet CLI Command Injection (CVE-2017-6650) | 25 Jul 202300:00 | – | nessus |
# Copyright (C) 2017 Greenbone Networks GmbH
# Some text descriptions might be excerpted from (a) referenced
# source(s), and are Copyright (C) by the respective right holder(s).
#
# SPDX-License-Identifier: GPL-2.0-or-later
#
# This program is free software; you can redistribute it and/or
# modify it under the terms of the GNU General Public License
# as published by the Free Software Foundation; either version 2
# of the License, or (at your option) any later version.
#
# This program is distributed in the hope that it will be useful,
# but WITHOUT ANY WARRANTY; without even the implied warranty of
# MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
# GNU General Public License for more details.
#
# You should have received a copy of the GNU General Public License
# along with this program; if not, write to the Free Software
# Foundation, Inc., 51 Franklin St, Fifth Floor, Boston, MA 02110-1301 USA.
CPE = "cpe:/o:cisco:nx-os";
if (description)
{
script_oid("1.3.6.1.4.1.25623.1.0.106813");
script_version("2022-12-26T10:12:01+0000");
script_tag(name:"last_modification", value:"2022-12-26 10:12:01 +0000 (Mon, 26 Dec 2022)");
script_tag(name:"creation_date", value:"2017-05-18 09:57:58 +0700 (Thu, 18 May 2017)");
script_tag(name:"cvss_base", value:"4.6");
script_tag(name:"cvss_base_vector", value:"AV:L/AC:L/Au:N/C:P/I:P/A:P");
script_tag(name:"severity_vector", value:"CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H");
script_tag(name:"severity_origin", value:"NVD");
script_tag(name:"severity_date", value:"2019-10-03 00:03:00 +0000 (Thu, 03 Oct 2019)");
script_cve_id("CVE-2017-6650");
script_tag(name:"qod_type", value:"remote_banner");
script_tag(name:"solution_type", value:"VendorFix");
script_name("Cisco Nexus 5000 Series Switches Telnet CLI Command Injection Vulnerability (cisco-sa-20170517-nss1)");
script_category(ACT_GATHER_INFO);
script_copyright("Copyright (C) 2017 Greenbone Networks GmbH");
script_family("CISCO");
script_dependencies("gb_cisco_nx_os_consolidation.nasl");
script_mandatory_keys("cisco/nx_os/detected", "cisco/nx_os/device", "cisco/nx_os/model");
script_tag(name:"summary", value:"A vulnerability in the Telnet CLI command of Cisco NX-OS System
Software running on Cisco Nexus 5000 Series Switches could allow an authenticated, local attacker
to perform a command injection attack.");
script_tag(name:"vuldetect", value:"Checks if a vulnerable version is present on the target host.");
script_tag(name:"insight", value:"The vulnerability is due to insufficient input validation of
command arguments. An attacker could exploit this vulnerability by injecting crafted command
arguments into the Telnet CLI command.");
script_tag(name:"impact", value:"An exploit could allow the attacker to read or write arbitrary
files at the user's privilege level outside of the user's path.");
script_tag(name:"solution", value:"See the referenced vendor advisory for a solution.");
script_xref(name:"URL", value:"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20170517-nss1");
exit(0);
}
include("host_details.inc");
include("version_func.inc");
device = get_kb_item("cisco/nx_os/device");
if (!device || "Nexus" >!< device)
exit(0);
model = get_kb_item("cisco/nx_os/model");
if (!model || model !~ "^C?(3|35|5|6|7|9)[0-9]+")
exit(0);
if (!version = get_app_version(cpe: CPE, nofork: TRUE))
exit(0);
affected = make_list(
"7.1(1)N1(1)",
"7.1(2)N1(1)",
"7.1(3)N1(1)",
"7.1(3)N1(2)",
"7.1(3)N1(2.1)",
"7.1(3)N1(3.12)",
"7.1(4)N1(1)",
"7.2(0)D1(0.437)",
"7.2(0)N1(1)",
"7.2(0)ZZ(99.1)",
"7.2(1)N1(1)",
"7.3(0)N1(1)");
foreach af (affected) {
if (version == af) {
report = report_fixed_ver(installed_version: version, fixed_version: "See advisory");
security_message(port: 0, data: report);
exit(0);
}
}
exit(99);
Data
Build on a solid foundation with Vulners data
We provide the essential building blocks for cybersecurity solutions with comprehensive, structured, and constantly updated vulnerability and exploits data
Api
Power your application with Vulners API
The Vulners REST API offers reliable, high-performance access to vulnerability intelligence, with 99.9% SLA uptime and CDN-backed data delivery for seamless global access
App
Assess and manage vulnerabilities with Vulners tools
Built on top of Vulners' database and SDK, end-user solutions give security professionals and developers lightweight and powerful tools for vulnerability remediation
26 Dec 2022 00:00Current
7.8High risk
Vulners AI Score7.8
CVSS 24.6
CVSS 37.8
EPSS0.00909