Lucene search

K
nvd[email protected]NVD:CVE-2021-30061
HistoryApr 03, 2022 - 10:15 p.m.

CVE-2021-30061

2022-04-0322:15:14
web.nvd.nist.gov

7.2 High

CVSS2

Attack Vector

LOCAL

Attack Complexity

LOW

Authentication

NONE

Confidentiality Impact

COMPLETE

Integrity Impact

COMPLETE

Availability Impact

COMPLETE

AV:L/AC:L/Au:N/C:C/I:C/A:C

6.8 Medium

CVSS3

Attack Vector

PHYSICAL

Attack Complexity

LOW

Privileges Required

NONE

User Interaction

NONE

Scope

UNCHANGED

Confidentiality Impact

HIGH

Integrity Impact

HIGH

Availability Impact

HIGH

CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

0.001 Low

EPSS

Percentile

32.8%

On Schneider Electric ConneXium Tofino Firewall TCSEFEA23F3F22 before 03.23, TCSEFEA23F3F20/21, and Belden Tofino Xenon Security Appliance, physically proximate attackers can execute code via a crafted file on a USB stick.

Affected configurations

NVD
Node
beldentofino_xenon_security_applianceMatch-
AND
beldentofino_xenon_security_appliance_firmwareRange<03.2.03
Node
beldentofino_argon_fa-tsa-220-tx\/mmMatch-
AND
beldentofino_argon_fa-tsa-220-tx\/mm_firmwareMatch-
Node
beldentofino_argon_fa-tsa-220-tx\/txMatch-
AND
beldentofino_argon_fa-tsa-220-tx\/tx_firmwareMatch-
Node
beldentofino_argon_fa-tsa-220-mm\/txMatch-
AND
beldentofino_argon_fa-tsa-220-mm\/tx_firmwareMatch-
Node
beldentofino_argon_fa-tsa-220-mm\/mmMatch-
AND
beldentofino_argon_fa-tsa-220-mm\/mm_firmwareMatch-
Node
beldentofino_argon_fa-tsa-100-tx\/txMatch-
AND
beldentofino_argon_fa-tsa-100-tx\/tx_firmwareMatch-
Node
beldeneagle_20_tofino_943_987-505-mm\/mmMatch-
AND
beldeneagle_20_tofino_943_987-505-mm\/mm_firmwareMatch-
Node
beldeneagle_20_tofino_943_987-504-mm\/txMatch-
AND
beldeneagle_20_tofino_943_987-504-mm\/tx_firmwareMatch-
Node
beldeneagle_20_tofino_943_987-502_-tx\/mm_firmwareMatch-
AND
beldeneagle_20_tofino_943_987-502_-tx\/mmMatch-
Node
beldeneagle_20_tofino_943_987-501-tx\/tx_firmwareMatch-
AND
beldeneagle_20_tofino_943_987-501-tx\/txMatch-
Node
schneider-electrictcsefea23f3f20_firmwareMatch-
AND
schneider-electrictcsefea23f3f20Match-
Node
schneider-electrictcsefea23f3f21_firmwareMatch-
AND
schneider-electrictcsefea23f3f21Match-
Node
schneider-electrictcsefea23f3f22_firmwareRange<03.23
AND
schneider-electrictcsefea23f3f22Match-

7.2 High

CVSS2

Attack Vector

LOCAL

Attack Complexity

LOW

Authentication

NONE

Confidentiality Impact

COMPLETE

Integrity Impact

COMPLETE

Availability Impact

COMPLETE

AV:L/AC:L/Au:N/C:C/I:C/A:C

6.8 Medium

CVSS3

Attack Vector

PHYSICAL

Attack Complexity

LOW

Privileges Required

NONE

User Interaction

NONE

Scope

UNCHANGED

Confidentiality Impact

HIGH

Integrity Impact

HIGH

Availability Impact

HIGH

CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

0.001 Low

EPSS

Percentile

32.8%

Related for NVD:CVE-2021-30061