Lucene search

K
nvd[email protected]NVD:CVE-2020-25178
HistoryMar 18, 2022 - 6:15 p.m.

CVE-2020-25178

2022-03-1818:15:09
CWE-319
web.nvd.nist.gov

9.3 High

CVSS2

Attack Vector

NETWORK

Attack Complexity

MEDIUM

Authentication

NONE

Confidentiality Impact

COMPLETE

Integrity Impact

COMPLETE

Availability Impact

COMPLETE

AV:N/AC:M/Au:N/C:C/I:C/A:C

8.8 High

CVSS3

Attack Vector

NETWORK

Attack Complexity

LOW

Privileges Required

NONE

User Interaction

REQUIRED

Scope

UNCHANGED

Confidentiality Impact

HIGH

Integrity Impact

HIGH

Availability Impact

HIGH

CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H

0.001 Low

EPSS

Percentile

49.4%

ISaGRAF Workbench communicates with Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x using TCP/IP. This communication protocol provides various file system operations, as well as the uploading of applications. Data is transferred over this protocol unencrypted, which could allow a remote unauthenticated attacker to upload, read, and delete files.

Affected configurations

NVD
Node
schneider-electriceasergy_t300_firmwareRange2.7.1
AND
schneider-electriceasergy_t300Match-
Node
schneider-electriceasergy_c5_firmwareRange<1.1.0
AND
schneider-electriceasergy_c5Match-
Node
schneider-electricmicom_c264_firmwareRange<d6.1
AND
schneider-electricmicom_c264Match-
Node
schneider-electricpacis_gtw_firmwareMatch5.1windows
OR
schneider-electricpacis_gtw_firmwareMatch5.2windows
OR
schneider-electricpacis_gtw_firmwareMatch6.1windows
OR
schneider-electricpacis_gtw_firmwareMatch6.3linux
OR
schneider-electricpacis_gtw_firmwareMatch6.3windows
AND
schneider-electricpacis_gtwMatch-
Node
schneider-electricsaitel_dp_firmwareRange11.06.21
AND
schneider-electricsaitel_dpMatch-
Node
schneider-electricepas_gtw_firmwareMatch6.4linux
OR
schneider-electricepas_gtw_firmwareMatch6.4windows
AND
schneider-electricepas_gtwMatch-
Node
schneider-electricsaitel_dr_firmwareRange11.06.12
AND
schneider-electricsaitel_drMatch-
Node
schneider-electricscd2200_firmwareRange10024
AND
schneider-electriccp-3Match-
OR
schneider-electricmc-31Match-
Node
rockwellautomationaadvance_controllerRange1.40
OR
rockwellautomationisagraf_free_runtimeRange6.6.8isagraf6_workbench
OR
rockwellautomationisagraf_runtimeRange5.06.0
Node
rockwellautomationmicro810_firmwareMatch-
AND
rockwellautomationmicro810Match-
Node
rockwellautomationmicro820_firmwareMatch-
AND
rockwellautomationmicro820Match-
Node
rockwellautomationmicro830_firmwareMatch-
AND
rockwellautomationmicro830Match-
Node
rockwellautomationmicro850_firmwareMatch-
AND
rockwellautomationmicro850Match-
Node
rockwellautomationmicro870_firmwareMatch-
AND
rockwellautomationmicro870Match-
Node
xylemmultismart_firmwareRange<3.2.0

9.3 High

CVSS2

Attack Vector

NETWORK

Attack Complexity

MEDIUM

Authentication

NONE

Confidentiality Impact

COMPLETE

Integrity Impact

COMPLETE

Availability Impact

COMPLETE

AV:N/AC:M/Au:N/C:C/I:C/A:C

8.8 High

CVSS3

Attack Vector

NETWORK

Attack Complexity

LOW

Privileges Required

NONE

User Interaction

REQUIRED

Scope

UNCHANGED

Confidentiality Impact

HIGH

Integrity Impact

HIGH

Availability Impact

HIGH

CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H

0.001 Low

EPSS

Percentile

49.4%

Related for NVD:CVE-2020-25178