An Information Exposure issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 programmable-logic controllers 1763-L16AWA, Series A and B, Version 16.00 and prior versions; 1763-L16BBB, Series A and B, Version 16.00 and prior versions; 1763-L16BWA, Series A and B, Version 16.00 and prior versions; and 1763-L16DWD, Series A and B, Version 16.00 and prior versions and Allen-Bradley MicroLogix 1400 programmable logic controllers 1766-L32AWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWAA, Series A and B, Version 16.00 and prior versions; 1766-L32BXB, Series A and B, Version 16.00 and prior versions; 1766-L32BXBA, Series A and B, Version 16.00 and prior versions; and 1766-L32AWAA, Series A and B, Version 16.00 and prior versions. User credentials are sent to the web server using the HTTP GET method, which may result in the credentials being logged. This could make user credentials available for unauthorized retrieval.

Affected configurations

NVD
Node
rockwellautomation1763-l16awa_series_aRange16.000
OR
rockwellautomation1763-l16awa_series_bRange16.000
OR
rockwellautomation1763-l16bbb_series_aRange16.000
OR
rockwellautomation1763-l16bbb_series_bRange16.000
OR
rockwellautomation1763-l16bwa_series_aRange16.000
OR
rockwellautomation1763-l16bwa_series_bRange16.000
OR
rockwellautomation1763-l16dwd_series_aRange16.000
OR
rockwellautomation1763-l16dwd_series_bRange16.000
AND
rockwellautomationab_micrologix_controllerMatch1100
Node
rockwellautomation1766-l32awa_series_aRange16.000
OR
rockwellautomation1766-l32awa_series_bRange16.000
OR
rockwellautomation1766-l32awaa_series_aRange16.000
OR
rockwellautomation1766-l32awaa_series_bRange16.000
OR
rockwellautomation1766-l32bwa_series_aRange16.000
OR
rockwellautomation1766-l32bwa_series_bRange16.000
OR
rockwellautomation1766-l32bwaa_series_aRange16.000
OR
rockwellautomation1766-l32bwaa_series_bRange16.000
OR
rockwellautomation1766-l32bxb_series_aRange16.000
OR
rockwellautomation1766-l32bxb_series_bRange16.000
OR
rockwellautomation1766-l32bxba_series_aRange16.000
OR
rockwellautomation1766-l32bxba_series_bRange16.000
AND
rockwellautomationab_micrologix_controllerMatch1400

5 Medium

CVSS2

Attack Vector

NETWORK

Attack Complexity

LOW

Authentication

NONE

Confidentiality Impact

PARTIAL

Integrity Impact

NONE

Availability Impact

NONE

AV:N/AC:L/Au:N/C:P/I:N/A:N

9.8 High

CVSS3

Attack Vector

NETWORK

Attack Complexity

LOW

Privileges Required

NONE

User Interaction

NONE

Scope

UNCHANGED

Confidentiality Impact

HIGH

Integrity Impact

HIGH

Availability Impact

HIGH

CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

9.3 High

AI Score

Confidence

High

0.001 Low

EPSS

Percentile

24.3%

Related for NVD:CVE-2017-7899