Siemens SIMATIC S7-1500 TM MFP Improper Input Validation (CVE-2026-53350)
| Reporter | Title | Published | Views | Family All 90 |
|---|---|---|---|---|
| CVE-2026-53350 | 1 Jul 202613:32 | – | attackerkb | |
| CVE-2026-53350 | 1 Jul 202622:46 | – | circl | |
| CVE-2026-53350 | 1 Jul 202613:32 | – | cve | |
| CVE-2026-53350 ASoC: wm_adsp: Fix NULL dereference when removing firmware controls | 1 Jul 202613:32 | – | cvelist | |
| [SECURITY] [DLA 4665-1] linux security update | 3 Jul 202618:38 | – | debian | |
| [SECURITY] [DLA 4671-1] linux-6.1 security update | 5 Jul 202618:24 | – | debian | |
| CVE-2026-53350 | 1 Jul 202613:32 | – | debiancve | |
| Debian dla-4665 : affs-modules-6.1.0-48-4kc-malta-di - security update | 3 Jul 202600:00 | – | nessus | |
| Debian dla-4671 : linux-config-6.1 - security update | 6 Jul 202600:00 | – | nessus | |
| openSUSE 16: cluster-md-kmp-64kb / cluster-md-kmp-azure / cluster-md-kmp-default / etc (openSUSE-SU-2026:21555-1) | 13 Aug 202600:00 | – | nessus |
10
#%NASL_MIN_LEVEL 80900
##
# (C) Tenable, Inc.
##
include('compat.inc');
if (description)
{
script_id(506386);
script_version("1.2");
script_set_attribute(attribute:"plugin_modification_date", value:"2026/10/21");
script_cve_id("CVE-2026-53350");
script_name(english:"Siemens SIMATIC S7-1500 TM MFP Improper Input Validation (CVE-2026-53350)");
script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
script_set_attribute(attribute:"description", value:
"In the Linux kernel, the following vulnerability has been resolved:
ASoC: wm_adsp: Fix NULL dereference when removing firmware controls
In wm_adsp_control_remove() check that the priv pointer is not NULL
before attempting to cleanup what it points to.
When cs_dsp creates a control it calls wm_adsp_control_add_cb() so that
wm_adsp can create its own private control data. There are two cases
where private data is not created:
1. The control is a SYSTEM control, so an ALSA control is not created.
2. The codec driver has registered a control_add() callback that
hides the control, so wm_adsp_control_add() is not called.
When cs_dsp_remove destroys its control list it calls
wm_adsp_control_remove() for each control. But wm_adsp_control_remove()
was attempting to cleanup the private data pointed to by cs_ctl->priv
without checking the pointer for NULL.
This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.");
script_set_attribute(attribute:"see_also", value:"https://cert-portal.siemens.com/productcert/html/ssa-784472.html");
script_set_attribute(attribute:"solution", value:
"Refer to the vendor advisory.");
script_set_cvss_base_vector("CVSS2#AV:L/AC:L/Au:S/C:N/I:N/A:C");
script_set_cvss_temporal_vector("CVSS2#E:U/RL:OF/RC:C");
script_set_cvss3_base_vector("CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H");
script_set_cvss3_temporal_vector("CVSS:3.0/E:U/RL:O/RC:C");
script_set_attribute(attribute:"cvss_score_source", value:"CVE-2026-53350");
script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
script_set_attribute(attribute:"exploit_available", value:"false");
script_cwe_id(20);
script_set_attribute(attribute:"vuln_publication_date", value:"2026/10/13");
script_set_attribute(attribute:"patch_publication_date", value:"2026/10/13");
script_set_attribute(attribute:"plugin_publication_date", value:"2026/10/20");
script_set_attribute(attribute:"plugin_type", value:"remote");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:simatic_s7-1500_tm_mfp");
script_set_attribute(attribute:"generated_plugin", value:"former");
script_end_attributes();
script_category(ACT_GATHER_INFO);
script_family(english:"Tenable.ot");
script_copyright(english:"This script is Copyright (C) 2026 and is owned by Tenable, Inc. or an Affiliate thereof.");
script_dependencies("tenable_ot_api_integration.nasl");
script_require_keys("Tenable.ot/Siemens");
exit(0);
}
include('tenable_ot_cve_funcs.inc');
get_kb_item_or_exit('Tenable.ot/Siemens');
var asset = tenable_ot::assets::get(vendor:'Siemens');
var vuln_cpes = {
"cpe:/o:siemens:simatic_s7-1500_tm_mfp" :
{"versionEndIncluding" : "1.1.1", "versionStartIncluding" : "1.1.1", "family" : "S71500", "orderNumbers": ["6ES7558-1AA00-0AB0"]}
};
tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_WARNING);
Data
Build on a solid foundation with Vulners data
We provide the essential building blocks for cybersecurity solutions with comprehensive, structured, and constantly updated vulnerability and exploits data
Api
Power your application with Vulners API
The Vulners REST API offers reliable, high-performance access to vulnerability intelligence, with 99.9% SLA uptime and CDN-backed data delivery for seamless global access
App
Assess and manage vulnerabilities with Vulners tools
Built on top of Vulners' database and SDK, end-user solutions give security professionals and developers lightweight and powerful tools for vulnerability remediation
21 Oct 2026 00:00Current
5.5Medium risk
Vulners AI Score5.5
CVSS 3.15.5
EPSS0.0012