Siemens SIMATIC S7-1500 TM MFP Improper Input Validation (CVE-2026-53325)
| Reporter | Title | Published | Views | Family All 132 |
|---|---|---|---|---|
| CVE-2026-53325 | 29 Jun 202604:53 | – | attackerkb | |
| Astra Linux – Vulnerability found in Linux 5.10, Linux 6.1 | 5 Oct 202611:39 | – | astralinux | |
| Linux kernel Heap Buffer Overflow DoS | 4 Sep 202600:00 | – | bdu_fstec | |
| CVE-2026-53325 affecting package kernel for versions less than 6.6.144.1-1 | 17 Jul 202603:27 | – | cbl_mariner | |
| CVE-2026-53325 vulnerabilities | 8 Jul 202602:17 | – | cgr | |
| CVE-2026-53325 | 29 Jun 202607:52 | – | circl | |
| CVE-2026-53325 | 29 Jun 202604:53 | – | cve | |
| CVE-2026-53325 agp/amd64: Fix broken error propagation in agp_amd64_probe() | 29 Jun 202604:53 | – | cvelist | |
| [SECURITY] [DLA 4688-1] linux security update | 18 Jul 202614:17 | – | debian | |
| [SECURITY] [DLA 4700-1] linux-6.1 security update | 26 Jul 202610:42 | – | debian |
10
#%NASL_MIN_LEVEL 80900
##
# (C) Tenable, Inc.
##
include('compat.inc');
if (description)
{
script_id(506314);
script_version("1.2");
script_set_attribute(attribute:"plugin_modification_date", value:"2026/10/21");
script_cve_id("CVE-2026-53325");
script_name(english:"Siemens SIMATIC S7-1500 TM MFP Improper Input Validation (CVE-2026-53325)");
script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
script_set_attribute(attribute:"description", value:
"In the Linux kernel, the following vulnerability has been resolved:
agp/amd64: Fix broken error propagation in agp_amd64_probe()
A NULL pointer dereference was observed in the AMD64 AGP driver when
running in a virtualized environment (e.g. qemu/kvm) without a physical
AMD northbridge. The crash occurs in amd64_fetch_size() when attempting
to dereference the pointer returned by node_to_amd_nb(0).
The root cause of this crash is broken error propagation in
agp_amd64_probe(): When no AMD northbridges are found, cache_nbs()
correctly returns -ENODEV. However, the probe function erroneously
checks the return value against exactly -1, rather than < 0.
As a result, the hardware absence error is masked, allowing the driver
to improperly proceed with initialization. It eventually calls
agp_add_bridge(), which invokes amd64_fetch_size(). Since the hardware
does not exist, node_to_amd_nb(0) returns NULL, leading to a General
Protection Fault (GPF) when accessing its ->misc member.
Fix the issue by correcting the error check in agp_amd64_probe() to
abort properly when cache_nbs() returns any negative error code. This
prevents the driver from erroneously proceeding without hardware, thereby
avoiding the subsequent NULL pointer dereference at its source.
This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.");
script_set_attribute(attribute:"see_also", value:"https://cert-portal.siemens.com/productcert/html/ssa-784472.html");
script_set_attribute(attribute:"solution", value:
"Refer to the vendor advisory.");
script_set_cvss_base_vector("CVSS2#AV:L/AC:L/Au:S/C:N/I:N/A:C");
script_set_cvss_temporal_vector("CVSS2#E:U/RL:OF/RC:C");
script_set_cvss3_base_vector("CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H");
script_set_cvss3_temporal_vector("CVSS:3.0/E:U/RL:O/RC:C");
script_set_attribute(attribute:"cvss_score_source", value:"CVE-2026-53325");
script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
script_set_attribute(attribute:"exploit_available", value:"false");
script_cwe_id(20);
script_set_attribute(attribute:"vuln_publication_date", value:"2026/10/13");
script_set_attribute(attribute:"patch_publication_date", value:"2026/10/13");
script_set_attribute(attribute:"plugin_publication_date", value:"2026/10/20");
script_set_attribute(attribute:"plugin_type", value:"remote");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:simatic_s7-1500_tm_mfp");
script_set_attribute(attribute:"generated_plugin", value:"former");
script_end_attributes();
script_category(ACT_GATHER_INFO);
script_family(english:"Tenable.ot");
script_copyright(english:"This script is Copyright (C) 2026 and is owned by Tenable, Inc. or an Affiliate thereof.");
script_dependencies("tenable_ot_api_integration.nasl");
script_require_keys("Tenable.ot/Siemens");
exit(0);
}
include('tenable_ot_cve_funcs.inc');
get_kb_item_or_exit('Tenable.ot/Siemens');
var asset = tenable_ot::assets::get(vendor:'Siemens');
var vuln_cpes = {
"cpe:/o:siemens:simatic_s7-1500_tm_mfp" :
{"versionEndIncluding" : "1.1.1", "versionStartIncluding" : "1.1.1", "family" : "S71500", "orderNumbers": ["6ES7558-1AA00-0AB0"]}
};
tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_WARNING);
Data
Build on a solid foundation with Vulners data
We provide the essential building blocks for cybersecurity solutions with comprehensive, structured, and constantly updated vulnerability and exploits data
Api
Power your application with Vulners API
The Vulners REST API offers reliable, high-performance access to vulnerability intelligence, with 99.9% SLA uptime and CDN-backed data delivery for seamless global access
App
Assess and manage vulnerabilities with Vulners tools
Built on top of Vulners' database and SDK, end-user solutions give security professionals and developers lightweight and powerful tools for vulnerability remediation
21 Oct 2026 00:00Current
5.4Medium risk
Vulners AI Score5.4
CVSS 3.15.5
EPSS0.0013